Description
1. Product Presentation
The polypropylene suture Premisut Prime that we offer at Cahnos is the reference solution for professionals seeking a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction. This presentation in USP 1 calibre, with a ⅜ circle needle with a 30 mm reverse cutting triangular point (DS30 profile) and a 75 cm blue thread, is especially indicated for surgical departments, purchasing centres and tenders that value a sterile, traceable product ready for the operating theatre, with a very competitive price-quality ratio compared with the major brands on the market.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin extruded as an uncoated monofilament. As it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase. It is therefore the classic choice in cardiovascular and vascular surgery and in long-lasting sutures.
The ⅜ circle needle with a reverse cutting triangular point (reverse cutting) has the cutting edge on the outer side of the curve, allowing it to pass through firm, non-distensible tissues with a clean cut, reducing the risk of tearing. The Prime finish provides a grooved-body needle with improved penetration and a more resistant tip compared with the standard Premisut quality. The blue colour of the strand ensures optimal visibility on the surgical field and safe control during knotting.
3. Technical Specifications
| Characteristic | Specification |
| Brand / Line | Premisut Prime (polypropylene) |
| Material | Polypropylene monofilament, uncoated, dyed blue |
| Structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 1 (metric EP 4); conforms to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Fluted blue (high visibility) |
| Needle shape | ⅜ circle (3/8 circular) |
| Needle tip | Reverse cutting triangular (reverse cutting), grooved body |
| Needle size | 30 mm (DS30 Prime model) |
| Sterilisation | Ethylene oxide (EO) – sterile, single-use, not resterilisable |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DS3001 |
| Reference Cahnos (SKU) | AMP732DS3001 |
Range Premisut DS30 (⅜ circle needle, grooved reverse cutting triangular point, blue, 75 cm):
| Needle size | USP | Thread (cm) | Reference |
| DS 30 | 4/0 | 75 | 732DS3040 (AM732DS3040) |
| DS 30 | 3/0 | 75 | 732DS3030 (AM732DS3030) |
| DS 30 | 2/0 | 75 | 732DS3020 (AM732DS3020) |
| DS 30 | 0 | 75 | 732DS3010 (AM732DS3010) |
| DS 30 | 1 | 75 | 732DS3001 (AM732DS3001) / P732DS3001 (AMP732DS3001 – this product) |
4. Equivalences and Cross-References
Non-absorbable monofilament polypropylene is one of the most widespread permanent suture families in the surgical market. The reference commercial ranges are PROLENE® (Ethicon / Johnson & Johnson MedTech), Premilene® (B. Braun) and Surgipro™ II (Medtronic / Covidien). There is no official equivalence table validated by the manufacturer that cross-references this specific product against other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Differences / Notes |
| Cahnos (Premisut) | Polypropylene 3/8 DS30, USP 1, blue, 75 cm | AM732DS3001 (ref. 732DS3001) | Configuration equivalence within the same system | Same needle, calibre, colour and length with standard quality control; this reference is the Prime version |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, USP 1, 75 cm | 8425H (CT-1 needle, ½ circle, 36 mm) | Comparable by category, not interchangeable 1:1 | Code verified in catalogue and distributors; it matches in USP 1, colour and length, but the needle geometry (½ circle conical) differs from the ⅜ reverse cutting |
| Ethicon (J&J MedTech) | PROLENE® – FSL/FSLX series ⅜ circle reverse cutting | 8690H (USP 0, FSLX 36 mm, 75 cm) · 8675H (3/0, FSL 30 mm, 75 cm) | Comparable by category / pending confirmation | Series with ⅜ reverse cutting needle verified in other calibres; no public code with USP 1 and 30 mm needle was found: confirm with the manufacturer |
| B. Braun | Premilene® – uncoated blue monofilament polypropylene | C series (C2090153 – USP 1, 75 cm, HR 37 mm needle) | Comparable by category, not interchangeable 1:1 | Same material, calibre and length; HR ½ circle needle versus the DS30 ⅜ reverse cutting; no public code with DS30 needle found: verify with the manufacturer |
| Medtronic / Covidien | Surgipro™ II – polypropylene copolymer with polyethylene, blue | SP / CP / PP series (consult official catalogue) | Pending confirmation | Copolymer material (not pure polypropylene); confirm reference, geometry and needle size against the IFU |
| Assut Europe | Assupro® – blue polypropylene monofilament | DS30 series according to official catalogue (consult) | Pending confirmation | Sector family with the same clinical indication; the combination USP 1 + DS30 needle is not confirmed in public sources: not interchangeable without validation |
Technical note: before substituting in a tender or operating theatre, verify one by one the exact calibre, thread length, needle shape and point, needle size, material, surface treatment and regulatory classification (CE/MDR) of the actual product from each manufacturer. The brands cited belong to their respective manufacturers and are mentioned for reference only. Consult the technical department at Cahnos before using this information in tenders.
5. Selection tips and variants of interest
- Calibre: USP 1 (metric 4) provides high tensile strength, indicated for planes subject to greater mechanical demand, fasciae and ligatures of medium-calibre vessels. For more delicate tissues, the same DS30 needle is available in USP 0 (AM732DS3010), USP 2/0 (AM732DS3020), USP 3/0 (AM732DS3030) and USP 4/0 (AM732DS3040).
- Needle size: the 30 mm DS30 is ideal for medium working fields and fibrous tissues; for deeper planes consider the DS36 (AM732DS3601) and for reduced fields the DS24 (AM732DS2401) from the same Premisut family.
- Prime quality: the Prime range adds a grooved-body needle with improved penetration compared with the standard Premisut line, an advantage in fibrous tissues and high-precision procedures.
- Traceability: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure and keep the reference P732DS3001 and the batch number for traceability in the operating theatre.
- For special volume-based B2B conditions, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.