Description
1. Product Presentation
The Premisut Prime polypropylene suture in USP 1 gauge and double presentation (2 × 75 cm) is the reference solution for surgery departments, purchasing centres and tenders that require a non-absorbable monofilament with predictable behaviour, excellent handling and minimal tissue reaction. Its ⅜ circle 24 mm needle with grooved reverse cutting triangular point (DS24 profile) provides firm, controlled penetration in soft tissues and skin planes, while the 75 cm blue thread ensures high visibility in the field and great tensile strength. Each unit is supplied sterile, ready for immediate use, in a box of 12 individual pouches with batch traceability, facilitating hospital stock management and presentation for public tender.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin extruded as an uncoated monofilament: lacking interstices and wick effect, it offers very smooth passage through tissue, does not promote bacterial adherence or sinus formation in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it becomes gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The ⅜ circle needle with reverse cutting triangular point (reverse cutting) places the cutting edge on the outer curve of the needle, allowing it to penetrate firm, non-distensible tissues (skin, fascia, subcutaneous) with a clean, stable cut, minimising the risk of tearing; the Prime finish provides a grooved needle body with improved penetration and a stronger tip compared to standard quality. The blue colour of the strand provides optimal visibility on the surgical field and secure control during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Brand / Quality | Premisut Prime (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption type | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 1 (metric EP 4); diameter 0.40 – 0.49 mm according to USP Pharmacopoeia |
| Thread length | 2 × 75 cm (2 threads per unit, double format) |
| Thread colour | Identification blue (high visibility in the field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Reverse-cutting triangular point, grooved, DS profile |
| Needle size | DS24 (24 mm) Prime |
| Sterilisation | Ethylene oxide (EO) – sterile, single-use, not resterilisable |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DS2401.2 |
| Reference Cahnos (SKU) | AMP732DS2401.2 |
Premisut Prime DS24 range (⅜ circle needle, grooved reverse cutting triangular point, blue, 75 cm):
| USP size | Presentation | Line reference | SKU Cahnos |
| 4/0 | 1 × 75 cm | P732DS2440 | AMP732DS2440 |
| 3/0 | 2 × 75 cm | P732DS2430.2 | AMP732DS2430.2 |
| 2/0 | 2 × 75 cm | P732DS2420.2 | AMP732DS2420.2 |
| 0 | 2 × 75 cm | P732DS2410.2 | AMP732DS2410.2 |
| 1 | 2 × 75 cm | P732DS2401.2 | AMP732DS2401.2 (this product) |
4. Equivalences and Cross-References
Important: there is no equivalence table validated by the manufacturer that cross-references this product with other brands. The following comparisons are functional, at category level, and not interchangeable 1:1; always confirm them against the technical data sheet and IFU of each manufacturer before using them in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS24, USP 1, blue, 75 cm (single thread) | AMP732DS2401 (Ref. P732DS2401) | Direct equivalence within the catalogue (1-thread configuration) | Same DS24 needle, same USP 1 gauge, same colour and material; the number of threads per pack changes (1 vs 2). |
| Cahnos (Premisut, standard quality) | Polypropylene 3/8 DS24, USP 1, blue, 75 cm | AM732DS2401 (Ref. 732DS2401) | Direct equivalence within the catalogue (standard quality) | Same needle geometry and gauge; the Prime finish (grooved needle with improved penetration) and number of threads vary. |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue monofilament polypropylene | 8425H (USP 1, 75 cm, CT-1 ½ circle needle, conical point, 36 mm) | Comparable by category, not interchangeable 1:1 | Code verified in official catalogue and authorised distributors. Matches in material, USP 1 gauge, colour and length, but the needle geometry (CT-1 conical ½ circle) differs from the ⅜ reverse cutting DS24. Pack of 36 units. |
| B. Braun (Aesculap) | Premilene® – uncoated blue monofilament polypropylene | C2090153 (USP 1 (4), 75 cm, HR37 ½ circle needle) | Comparable by category, not interchangeable 1:1 | Code verified in official catalogue and distributors. Same base material, gauge and length; HR needle of 37 mm (½ circle, conical point) vs the DS24 of ⅜ reverse cutting. Pack of 36 units. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene copolymer with polyethylene | SP / CP / PP series (consult official catalogue according to needle) | Pending confirmation | Copolymer material (not pure polypropylene); no public code consistent with USP 1 + ⅜ reverse cutting needle of 24 mm was found. Verify against the IFU. |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | Consult code according to gauge and needle | Pending confirmation | Family in the sector with same clinical indication; the combination USP 1 + DS needle of 24 mm is not confirmed in public sources. Not interchangeable without validation. |
| Chirana / CPT | Chiralen® / TRUSTILENE® – blue monofilament polypropylene | Consult official catalogue (DS 24/25 family) | Pending confirmation | Same family and indication; confirm gauge, needle length and presentation before substituting. |
Technical note: before any formal substitution, verify one by one the exact gauge, thread length, needle shape and point, needle size, material, surface treatment and regulatory classification (CE/MDR) of the actual product from each manufacturer. The brands cited belong to their respective manufacturers and are mentioned for reference only. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
- Number of threads: the double presentation 2 × 75 cm (AMP732DS2401.2) is indicated for high-consumption procedures or when two identical strands are required per pack opening; if the protocol prefers a single thread, request version AMP732DS2401 (1 × 75 cm, same DS24 and USP 1 gauge).
- Gauge: USP 1 (metric 4) offers high tensile strength for planes subjected to greater mechanical stress, fasciae and tension ligatures. With the same DS24 needle, it is available in USP 4/0 (AMP732DS2440), 3/0 (AMP732DS2430.2), 2/0 (AMP732DS2420.2) and 0 (AMP732DS2410.2).
- Needle size: the 24 mm DS24 is ideal for superficial planes and areas of limited access; for wider fields in the same USP 1 gauge, consider DS30 (AMP732DS3001) or DS36 (AMP732DS3601.2).
- Prime Quality: the Prime range offers a grooved-body needle with improved penetration and a stronger tip compared to the standard Premisut line, an advantage in fibrous tissues and high-precision procedures.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure and keep the reference P732DS2401.2 and the batch number for traceability in the operating theatre.
- For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews