Description
1. Commercial Introduction
The polypropylene suture Premisut Prime that Cahnos makes available to surgical services, purchasing centres and tenders is the reference choice when a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction is required. This presentation incorporates a ⅜ circle needle with a grooved reverse cutting triangular point of 16 mm (DS16 Prime profile), USP 4/0 gauge and a 75 cm strand in high-visibility blue: a fine and precise configuration, widely used in superficial planes, delicate tissues, ligatures and cardiovascular surgery, ophthalmology, neurosurgery and general surgery procedures.
It is supplied sterile, ready for individual use, with batch traceability, facilitating the management of hospital stocks and presentation to public tenders. Available under the factory reference P732DS1640 (SKU Cahnos AMP732DS1640), kept without altering characters: no digit may be added, removed or reordered when ordering or bidding.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) that is presented as an uncoated monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.
The DS16 Prime needle (⅜ circle, grooved reverse cutting triangular point of 16 mm) penetrates soft and poorly distensible tissues with a clean and stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage, even in reduced access planes or microsurgery. The grooved finish of the needle and thread facilitates smooth and consistent delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not resterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 4/0 (metric EP 1.5); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.150 – 0.199 mm (according to USP, non-absorbable suture) |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting point, grooved (DS profile) |
| Needle size | 16 mm (DS16 Prime profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Sterile individual sachet / box of 12 units; batch traceability |
| Factory reference | P732DS1640 |
| Reference Cahnos (SKU) | AMP732DS1640 |
Gauge equivalence according to USP (indicative):
| USP size | Metric size | Approximate diameter |
| 4/0 | 1.5 | 0.150 – 0.199 mm (non-absorbable suture) |
4. Equivalences and Cross-References
The reference P732DS1640 corresponds to the official nomenclature of the Premisut Prime range (DS16 Prime profile, single 75 cm strand, USP 4/0 gauge). Cahnos markets the product keeping the factory reference unchanged. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®, SERAPREN® or Surgipro™ are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut) | Polypropylene DS16, USP 4/0, blue, 75 cm (standard) | AM732DS1640 | Functional category equivalent | Same needle, gauge, colour and length; standard quality, needle without grooved body |
| Cahnos (Premisut Prime) | Polypropylene DS16 Prime, USP 3/0, blue, 75 cm | AMP732DS1630 | Comparable within the system | Same DS16 Prime needle and quality; 3/0 gauge of larger diameter |
| Cahnos (Premisut Prime) | Polypropylene DS19 Prime, USP 4/0, blue, 75 cm | AMP732DS1940 | Comparable within the system | Same gauge and quality; DS19 needle of 19 mm versus DS16 |
| Cahnos (Premisut Prime) | Polypropylene DS12 Prime, USP 4/0, blue, 75 cm | AMP732DS1240 | Comparable within the system | Same gauge and quality; DS12 needle of 12 mm for smaller fields |
| Cahnos (Premisut Prime) | Polypropylene XDS16 Prime, USP 4/0, blue, 75 cm (precision, square body) | AMP732XDS1640 | Comparable by category, not interchangeable 1:1 | Same gauge and 16 mm; extra-long precision point with square body, not grooved |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 4/0 | 8699G / 8682G / 8683G (depending on P-3, PS-2 or FS-2 needle profile) | Comparable by category, not interchangeable 1:1 | Codes verified in authorised distribution for 4/0 gauge; the needle geometry and size of the PROLENE series differs from the DS16. Confirm CE/MDR traceability against IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 4/0 (1.5), DRT18 reverse cutting needle | C2090320 | Comparable by category, not interchangeable 1:1 | Code verified in distribution sources: same base material and gauge; 18 mm reverse cutting needle versus 16 mm DS16. Confirm geometry in official catalogue |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | 4/0 code not verified in this consultation | Comparable by category, not verified | Same base material (blue polypropylene monofilament); confirm code, needle and presentation in official catalogue before use |
| Medtronic (Covidien) | Surgipro™ II – polypropylene/polyethylene copolymer | 4/0 code not verified | Not verified | Copolymer material (not pure polypropylene); pending confirmation of reference and needle geometry against IFU |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the above comparisons are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tendering or substitution. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
Tissue to suture: the grooved reverse-cutting DS needle is suitable for soft, flat skin tissues requiring firm, controlled penetration in areas with limited access (cardiovascular surgery, ophthalmology, neurosurgery and general surgery). For lax or vascular tissues, consider round-point (HR) profiles from the same Premisut Prime range.
Needle size: the 16 mm DS16 is a compact needle, ideal for superficial planes, microsurgery and surgical fields with limited space. If the protocol requires a shorter needle in the same USP 4/0 gauge, the DS12 variant (AMP732DS1240) is available; if you prefer a larger one, the DS19 (AMP732DS1940) from the same Premisut Prime family.
Alternative gauges with the same DS16 needle: USP 3/0 (AMP732DS1630) for higher mechanical demands, and USP 6/0 (AMP732DS1660) for precision ophthalmic and cardiovascular microsurgery.
Length and presentation: this 75 cm reference offers sufficient margin for secure passes and knots; as an economical alternative, the standard Premisut quality (AM732DS1640) maintains the needle, gauge and colour. If the protocol requires an extra-long precision point with a square body, the XDS family offers the reference AMP732XDS1640.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DS1640 and the batch number for traceability in the operating theatre and in case of complaint. For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews