We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Polypropylene suture Premisut Prime 3/8 circle reverse cutting triangular point DS30 mm ribbed, USP 0, blue, 2 × 75 cm (Ref. P732DS3010.2) | Box 12 units

55,30 €

Non-absorbable monofilament polypropylene suture PREMISUT PRIME with a ⅜ circular needle with triangular reverse cutting grooved point of 30 mm (DS 30 Prime profile), USP 0 calibre and presentation of 2 threads of 75 cm in blue for maximum visibility in the field. Sterile by ethylene oxide and single-use, indicated for approximation of soft tissues, ligatures and cardiovascular surgery, ophthalmology and neurosurgery, with wound support for more than three months. Factory reference P732DS3010.2 (SKU AMP732DS3010.2). Price per box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP732DS3010.2

Description

1. Commercial Introduction

The polypropylene suture PREMISUT PRIME is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating tissue with total control. This presentation in USP 0 calibre, with a ⅜ circle needle with triangular reverse cutting grooved point of 30 mm (DS 30 Prime profile) and two 75 cm threads in blue, is especially indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.

It is supplied sterile and ready for the operating theatre in a box of 12 units with batch traceability, facilitating hospital stock management and presentation to public tenders. Available at Cahnos under the factory reference P732DS3010.2 (SKU AMP732DS3010.2), kept without altering characters.

2. Technical Explanation

Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia calibres, and is gradually encapsulated by connective tissue, supporting the wound for more than three months.

The DS 30 Prime needle (⅜ circle, triangular reverse cutting grooved point of 30 mm) penetrates soft and poorly distensible tissues with a clean and stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage. The grooved finish of the needle body facilitates smooth delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

Parameter Specification
Thread material Polypropylene monofilament, uncoated, dyed blue
Thread structure Monofilament with grooved surface
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
USP gauge / size USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges
Thread length 2 threads of 75 cm (2 × 75 cm) per unit
Thread colour Identification blue
Needle shape ⅜ circular (3/8 circle)
Needle type Triangular reverse cutting grooved point (DS profile)
Needle size 30 mm (DS 30 Prime profile)
Manufacturing quality Prime (premium range)
Sterilisation Ethylene oxide (EO) – sterile
Use Single-use, sterile. Do not re-sterilise
Indications Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery
Commercial presentation Box of 12 units (individual sterile sachets)
Factory reference P732DS3010.2
Reference Cahnos (SKU) AMP732DS3010.2

DS family (⅜ circle reverse cutting) in USP 0 calibre:

Needle profile USP Presentation Reference
DS 30 Prime 0 2 × 75 cm P732DS3010.2 / AMP732DS3010.2
DS 30 Prime 0 1 × 75 cm P732DS3010 / AMP732DS3010
DS 36 Prime 0 2 × 75 cm P732DS3610.2 / AMP732DS3610.2
DS 40 Prime 0 1 × 75 cm P732DS4010 / AMP732DS4010
DS 40 Prime 0 2 × 75 cm P732RDS4010.2 / AMP732RDS4010.2

4. Equivalences and Cross-References

The reference P732DS3010.2 corresponds to the official nomenclature of the Premisut Prime range (DS 30 Prime profile, double 75 cm thread). Cahnos markets the product keeping the factory reference without altering characters; the DS needle profile (reverse cutting) is only interchangeable within the Premisut system itself, varying the needle size or calibre. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Premisut Prime range (Cahnos) Polypropylene DS 30 Prime, USP 0, blue, 2 × 75 cm P732DS3010.2 / AMP732DS3010.2 Direct product reference Product analysed in this data sheet
Premisut Prime range (Cahnos) Polypropylene DS 30 Prime, USP 0, blue, 1 × 75 cm P732DS3010 / AMP732DS3010 Configuration equivalent within the same system Same DS 30 needle and USP 0 calibre; presentation changes to 1 thread of 75 cm
Premisut Prime range (Cahnos) Polypropylene DS 36 Prime, USP 0, blue, 2 × 75 cm AMP732DS3610.2 Comparable within the same system Same gauge and presentation; DS needle of 36 mm versus 30 mm
Premisut Prime range (Cahnos) Polypropylene DS 40 Prime, USP 0, blue, 2 × 75 cm AMP732RDS4010.2 Comparable within the same system Same gauge and presentation; DS needle of 40 mm versus 30 mm
Ethicon (Johnson & Johnson MedTech) PROLENE® – blue polypropylene monofilament, USP 0, 75 cm, FSLX needle 3/8 circle reverse cutting 8690H Comparable by category (no official cross-reference table) Matches in material, calibre, colour, thread length and 3/8 reverse cutting needle geometry, but the FSLX measures 36/40 mm compared to the 30 mm of the DS 30 Prime profile. Presentation in box of 36 units; confirm against IFU
B. Braun Premilene® / Optilene® (blue polypropylene monofilament, Easyslide needles) C2090199 / C3090199 – pending confirmation of 1:1 code for DS 30 USP 0 Comparable by category / pending confirmation Same blue polypropylene base; the exact combination of reverse cutting needle 30 mm + USP 0 + 2 × 75 cm has not been verified in public sources
Medtronic (Covidien) Surgipro™ II (polypropylene with polyethylene, blue monofilament) SP series – pending confirmation for USP 0 (e.g. SP-675 in 3/0 with C-16 needle) Comparable by category / pending confirmation Copolymer with polyethylene; confirm reference and needle geometry against IFU
Serag-Wiessner SERAPREN® (blue polypropylene monofilament, USP 8/0 to 0) Consult code according to gauge and needle Comparable by category / pending confirmation Non-absorbable blue polypropylene monofilament; verify gauge, size and needle geometry with the distributor

Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®/Optilene®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.

5. Selection tips and variants of interest

  • Tissue to suture: the grooved reverse cutting DS needle is suitable for soft and flat tissues that require firm and controlled penetration (skin, fascia, cardiovascular surgery, ophthalmology and neurosurgery). For lax or vascular tissues, consider round point profiles (HR) from the same Premisut Prime range.
  • Needle size: the 30 mm DS is an intermediate needle, ideal for medium suture planes and areas with reduced access; for wider fields, the DS 36 (AMP732DS3610.2) and DS 40 (AMP732RDS4010.2) are available in the same USP 0 calibre.
  • Calibre: USP 0 offers medium-high tension for soft tissues and ligatures; for less demanding planes, consider USP 2/0 (AMP732DS3020.2) or USP 3/0 (AMP732DS3030.2) with the same DS 30 profile.
  • Presentation: the 2 × 75 cm version reduces the opening of packaging per procedure compared to the single thread version (AMP732DS3010), being practical for continuous sutures or multiple passes.
  • Sterility verification: sterile product by ethylene oxide, single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DS3010.2 and the batch number for traceability in the operating theatre and in case of complaint.

Additional information

Material

Uncoated monofilament polypropylene

Structure

Grooved monofilament

Absorption

Non-absorbable; gradual encapsulation, support for more than 3 months

Gauge

USP 0 (metric EP 3.5)

Needle type

Triangular reverse cutting grooved point (DS profile)

Needle size

30 mm

Needle profile

DS 30 Prime

Quality

Prime (premium range)

Sterilisation

Ethylene oxide (EO)

Use

Single-use, not re-sterilisable

Presentation

Box of 12 units

Indications

Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery

Manufacturer reference

P732DS3010.2

Medida de aguja

DS 30

Usp

0

Color

Blue

Medida de hilo

2 × 75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Polypropylene suture Premisut Prime 3/8 circle reverse cutting triangular point DS30 mm ribbed, USP 0, blue, 2 × 75 cm (Ref. P732DS3010.2) | Box 12 units”

Your email address will not be published. Required fields are marked *