Description
The polypropylene suture PREMISUT PRIME is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating tissue with full control. This presentation in USP 1 gauge, with a ⅜ circle needle with reverse cutting triangular point, grooved, 36 mm (DS36 profile) and blue thread 75 cm, is especially indicated for soft tissue approximation, ligatures and high-demand procedures in cardiovascular surgery, ophthalmology and neurosurgery. It is supplied sterile, ready for the operating theatre, in a box of 12 units with full batch traceability.
Technical explanation
Polypropylene is a synthetic linear polyolefin extruded as an uncoated monofilament. Lacking interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or sinus formation in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.
The ⅜ circle needle with reverse cutting triangular point places the cutting edge on the outer curve, allowing it to penetrate firm, non-distensible tissues (skin, fascia, subcutaneous) with a clean cut, without weakening the needle body and reducing the risk of tearing; the grooved body facilitates passage through tissue minimising trauma. The Prime finish provides improved penetration and a stronger tip compared to the standard Premisut quality. The blue colour of the strand ensures optimal visibility on the surgical field and safe control during knotting.
Technical specifications
| Characteristic | Specification |
| Brand / Line | Premisut Prime (polypropylene) |
| Material | Polypropylene monofilament, uncoated, dyed blue |
| Structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 1 (metric EP 4); diameter approx. 0.400–0.499 mm according to USP Pharmacopoeia |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Ribbed blue (high visibility on the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting point, grooved body |
| Needle size | 36 mm (DS36 Prime profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DS3601 |
| Reference Cahnos (SKU) | AMP732DS3601 |
Equivalences and cross-references
Non-absorbable monofilament polypropylene is one of the most widespread permanent suture families in the surgical market; the reference homologous commercial ranges are PROLENE® (Ethicon / Johnson \u0026 Johnson MedTech), Premilene® (B. Braun), Surgipro™ II (Medtronic / Covidien) and SERAPREN® (Serag-Wiessner). There is no equivalence table validated by the manufacturer that cross-references this product with other brands; comparisons with those families are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or direct substitution. For guidance, in those ranges there are references in USP 1 gauge and 75 cm (e.g. PROLENE® 8425H with CT-1 ½ circle needle, or Premilene® C2090153 with HR needle), but none of them mounts the exact combination of ⅜ circle reverse cutting needle of 36 mm of this reference, so they are not interchangeable 1:1. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
Selection tips and variants of interest
- Gauge: USP 1 (metric 4) offers high tensile strength, indicated for planes subjected to greater mechanical stress, fasciae and ligatures of medium-calibre vessels. With the same DS36 Prime needle, it is available in USP 0 (AMP732DS3610), USP 2/0 and USP 3/0 within the Premisut Prime family.
- Needle size: the DS36 of 36 mm is ideal for medium planes, fibrous tissues and standard working fields; for more superficial planes consider the DS30 (AMP732DS3001) and for reduced fields the DS26 or DS24 from the same range.
- Presentation: if the procedure requires double strand, the same DS36 Prime USP 1 profile is available in 2 × 75 cm format (AMP732DS3601.2), which reduces the opening of packages per procedure.
- Prime quality: the Prime range provides a grooved-body needle with improved penetration and a stronger tip compared to the standard Premisut line, an advantage in fibrous tissues.
- Verification before use: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure and keep the reference P732DS3601 and the batch number for traceability in the operating theatre.





Reviews