Description
1. Commercial Introduction
The Premisut Prime polypropylene suture from Cahnos is the reference choice for surgical departments, purchasing centres and tenders that require a non-absorbable thread with predictable performance, excellent handling and minimal tissue reaction. This presentation incorporates a ⅜ circle needle with a grooved reverse cutting triangular point of 19 mm (DS19 profile), USP 5/0 gauge and a 45 cm strand in high-visibility blue: a fine, precise configuration widely used in superficial planes, delicate tissues, ligatures and cardiovascular surgery, ophthalmology, neurosurgery and general surgery procedures.
Supplied sterile, ready for single use, with batch traceability, facilitating hospital stock management and presentation for public tenders. Available under factory reference 731DS1950 (SKU Cahnos AM731DS1950), kept without altering characters. Price per box of 12 units.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or the formation of sinus tracts in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength over a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.
The DS19 reverse cutting needle supports the cutting edge towards the outer part of the curve, allowing it to pass through soft, non-distensible tissues —skin, muscle, scar tissue and microsurgery planes— with a clean, stable cut, without tearing and with controlled passage even in areas of limited access. The grooved finish of the needle body and suture facilitates smooth, consistent delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the manufacturer/distributor (Cahnos S.L.).
| Parameter | Specification |
| Brand / quality | Premisut Prime (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 5/0 (metric EP 1); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.100 – 0.149 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 45 cm (1 strand per unit) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Reverse cutting triangular point, grooved (DS profile) |
| Needle size | 19 mm (DS19 profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 731DS1950 |
| Reference Cahnos (SKU) | AM731DS1950 |
Premisut DS19 family (⅜ circle needle, reverse cutting triangular point, blue)
| Needle profile | USP size | Thread | Reference |
| DS19 Prime | 3/0 | 45 cm | P731DS1930 / AMP731DS1930 |
| DS19 Prime | 3/0 | 75 cm | P732DS1930 / AMP732DS1930 |
| DS19 Prime | 4/0 | 45 cm | P731DS1940 / AMP731DS1940 |
| DS19 Prime | 4/0 | 75 cm | P732DS1940 / AMP732DS1940 |
| DS19 Prime | 5/0 | 45 cm | P731DS1950 / AMP731DS1950 (this product) |
| DS19 Prime | 5/0 | 75 cm | P732DS1950 / AMP732DS1950 |
| DS19 Prime | 6/0 | 75 cm | P732DS1960 / AMP732DS1960 |
| DS19 (standard quality) | 5/0 | 45 cm | 731DS1950 / AM731DS1950 |
SKU note: the historical Cahnos code AM731DS1950 corresponds to factory reference 731DS1950 of the Premisut range; in the current catalogue the Prime version (grooved needle) is identified as P731DS1950 / AMP731DS1950. Confirm the coding with the technical department before tendering or ordering.
4. Equivalences and Cross-References
Reference 731DS1950 corresponds to the official nomenclature of the Premisut range (DS19 profile, single 45 cm strand, USP 5/0 gauge). Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene DS19, USP 5/0, blue, 75 cm | AMP732DS1950 | Direct range equivalent | Same DS19 needle, quality and colour; suture length varies (75 cm vs 45 cm) |
| Cahnos (Premisut Prime) | Polypropylene DS19, USP 4/0, blue, 45 cm | AMP731DS1940 | Direct range equivalent | Same DS19 needle and length; 4/0 gauge with larger diameter for delicate tissues |
| Cahnos (Premisut Prime) | Polypropylene DS19, USP 3/0, blue, 45 cm | AMP731DS1930 | Direct range equivalent | Same DS19 needle and length; 3/0 gauge for higher mechanical demand |
| Cahnos (Premisut Prime) | Polypropylene XDS19, USP 5/0, blue, 45 cm (precision, square body) | AMP731XDS1950 | Comparable within the system | Same gauge and length; extra-long precision point with square body, not grooved |
| Ethicon (Johnson & Johnson MedTech) | PROLENE – blue polypropylene monofilament, P-3 3/8 precision reverse cutting needle, 5/0, 45 cm | 8698G | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution (12 units/box): P-3 needle of 19 mm very close to DS19; same material, gauge and colour; confirm CE/MDR traceability against IFU |
| B. Braun | Premilene – blue polypropylene monofilament, 5/0 | 5/0 code not verified in this consultation | Comparable by category, not verified | Same base material and gauge; confirm needle geometry and exact reference in official catalogue before use |
| Medtronic (Covidien) | Surgipro II – polypropylene/polyethylene copolymer | 5/0 code not verified | Not verified | Copolymer material (not pure polypropylene); pending confirmation of reference and needle geometry against IFU |
| Serag-Wiessner | SERAPREN – blue polypropylene monofilament | 5/0 code not verified in this consultation | Comparable by category, not verified | Same base material (blue polypropylene monofilament); confirm code, needle and presentation in official catalogue before use |
Mandatory technical note: there is no equivalence table validated by the manufacturer cross-referencing this reference with other brands; comparisons with PROLENE, Premilene, SERAPREN or Surgipro are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tendering or substitution. Consult the Cahnos technical department to validate any equivalence before use.
5. Selection tips and variants of interest
- Tissue to suture: the DS reverse cutting needle is suitable for soft tissues and skin planes requiring firm, controlled penetration in areas of limited access (cardiovascular surgery, ophthalmology, neurosurgery and general surgery). For lax or vascular tissues, consider round point profiles (HR) from the same Premisut Prime range.
- Needle size: the 19 mm DS19 is a compact needle, ideal for superficial planes, microsurgery and surgical fields with limited space. If the protocol requires a shorter needle in the same USP 5/0 gauge, the DS16 (AMP731DS1650) and DS12 (AMP731DS1250) variants of the same Premisut Prime family are available.
- Alternative gauges with the same DS19 needle: USP 3/0 (AMP731DS1930) for higher mechanical demand, USP 4/0 (AMP731DS1940) for delicate tissues and USP 6/0 (AMP732DS1960) for precision ophthalmic and cardiovascular microsurgery.
- Length and presentation: this 45 cm reference is a compact and economical presentation for short passes or limited fields; for sutures with longer reach, the 75 cm version (AMP732DS1950) is available. If the protocol requires an extra-long precision point with a square body, the XDS family offers AMP731XDS1950 (5/0, 45 cm).
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 731DS1950 and the batch number for traceability in the operating theatre and in case of a claim.
- B2B conditions: for hospital supply agreements, public tenders or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.