1. Product Presentation
The polypropylene suture PREMISUT PRIME we offer at Cahnos is the reference solution for surgery departments, purchasing centres and tenders seeking a non-absorbable thread with predictable performance, excellent handling and minimal tissue reaction. This presentation incorporates a ⅜ circle needle with a 19 mm triangular reverse cutting grooved point (DS19 Prime profile), USP 3/0 gauge and a highly visible blue 45 cm thread: a compact and precise configuration, widely used in superficial planes, soft tissues, ligatures and cardiovascular surgery, ophthalmology, neurosurgery and general surgery procedures.
It is supplied sterile, ready for single use, with batch traceability, facilitating hospital stock management and submission to public tenders. Available under factory reference P731DS1930 (SKU Cahnos AMP731DS1930), kept without altering characters: no digit may be added, removed or reordered when ordering or bidding.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or the formation of sinus tracts in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength over a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.
The DS19 Prime needle (⅜ circle, 19 mm triangular reverse cutting grooved point) penetrates soft and poorly distensible tissues with a clean, stable cut: the reverse cutting geometry directs the cutting edge towards the outer part of the curve, reducing the risk of tearing in firm tissues and allowing controlled passage, even in restricted access planes or microsurgery. The grooved finish of the thread facilitates smooth, consistent delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 3/0 (EP metric 2); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.200 – 0.249 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 45 cm (1 strand per unit) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting point, grooved (DS profile) |
| Needle size | 19 mm (DS19 Prime profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P731DS1930 |
| Reference Cahnos (SKU) | AMP731DS1930 |
Family Premisut Prime DS19 (⅜ circle needle, triangular reverse cutting grooved point, blue):
| Needle profile | USP size | Thread | Reference |
| DS 19 Prime | 3/0 | 45 cm | P731DS1930 / AMP731DS1930 (this product) |
| DS 19 Prime | 3/0 | 75 cm | P732DS1930 / AMP732DS1930 |
| DS 19 Prime | 3/0 | 2 × 75 cm | P732DS1930.2 / AMP732DS1930.2 |
| DS 19 Prime | 4/0 | 75 cm | P732DS1940 / AMP732DS1940 |
| DS 19 Prime | 6/0 | 75 cm | P732DS1960 / AMP732DS1960 |
| DS 19 (standard quality) | 3/0 | 75 cm | 732DS1930 / AM732DS1930 |
4. Equivalences and Cross-References
Reference P731DS1930 corresponds to the official nomenclature of the Premisut Prime range (DS19 Prime profile, single 45 cm thread). Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS19, USP 3/0, blue, 75 cm | AMP732DS1930 | Direct range equivalent | Same DS19 needle, same gauge and colour; only the thread length varies (75 cm vs 45 cm) |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS19, USP 3/0, blue, 2 × 75 cm | AMP732DS1930.2 | Direct range equivalent | Same needle and gauge; double presentation of 2 threads per pack |
| Cahnos (Premisut) | Polypropylene 3/8 DS19, USP 3/0, blue, 75 cm (standard) | AM732DS1930 | Functional category equivalent | Same geometry, gauge and colour; standard quality with needle without grooved body |
| Cahnos (Premisut Prime) | Polypropylene 1/2 HS17, USP 3/0, blue, 45 cm | AMP731HS1730 | Comparable within the same system | Same length and gauge; ½ circle curvature with 17 mm HS17 needle |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, FS-1 3/8 reverse cutting needle | EH7694H | Comparable by category, not interchangeable 1:1 | Matches material, 3/0 gauge, colour and thread; FS-1 needle of 24 mm vs DS19 of 19 mm. Confirm batch and CE/MDR traceability against IFU |
| Ethicon (J&J MedTech) | PROLENE® – FSLX series 3/8 circle reverse cutting | 8649H | Comparable by category, not interchangeable 1:1 | Same material, gauge and colour; FSLX needle of 40 mm notably larger than the DS19 |
| B. Braun | Premilene® – blue polypropylene monofilament, DS30 needle | C0090246 | Comparable by category, not interchangeable 1:1 | Same base material, gauge and reference length; 30 mm needle vs 19 mm |
| Medtronic (Covidien) | Surgipro™ II – polypropylene copolymer with polyethylene, C-16 3/8 reverse cutting needle | SP-675 | Comparable by category, not interchangeable 1:1 | Copolymer material (not pure polypropylene), 3/0 blue gauge; confirm needle geometry and reference against IFU |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament, DS-30 needle | CO203416 | Comparable by category, not interchangeable 1:1 | Blue polypropylene monofilament 3/0 with 30 mm DS needle; verify batch and presentation |
Mandatory technical note: there is no equivalence table validated by the manufacturer cross-referencing this reference with other brands; comparisons with PROLENE®, Premilene®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or substitution. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
Tissue to suture: the grooved reverse cutting DS needle is suitable for soft tissues and skin planes requiring firm, controlled penetration in restricted access areas (cardiovascular surgery, ophthalmology, neurosurgery and general surgery). For lax or vascular tissues, consider round point (HR) profiles from the same Premisut Prime range.
Needle size: the 19 mm DS19 is a compact needle, ideal for superficial planes, microsurgery and surgical fields with limited space; for larger planes, the DS24, DS30 or DS36 variants of the same Premisut Prime family are available in USP 3/0 gauge.
Alternative gauges with the same DS19 needle: USP 4/0 (AMP732DS1940) for delicate tissues and USP 6/0 (AMP732DS1960) for precision ophthalmic and cardiovascular microsurgery.
Thread length: this 45 cm reference is an economical and compact presentation for short passes or limited fields; for longer sutures, a 75 cm version is available (AMP732DS1930) and, if the protocol requires a double strand, the 2 × 75 cm presentation (AMP732DS1930.2). As a cost alternative, the standard quality Premisut (AM732DS1930) keeps the same needle and configuration.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P731DS1930 and the batch number for traceability in the operating theatre and in case of a claim. For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.