Description
1. Commercial Introduction
The PREMISUT polypropylene suture we offer at Cahnos is the reference solution for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating tissue with full control. This presentation in USP 0 gauge, with a ⅜ circle needle with a fluted reverse cutting triangular point of 36 mm (DS36 profile) and a 75 cm blue thread, is particularly indicated for approximation of soft tissues, ligatures and procedures in cardiovascular surgery, ophthalmology and neurosurgery. It is supplied sterile, ready for the operating theatre, in a box of 12 units with batch traceability. A very competitive quality-price ratio for equipping operating theatres and replenishing hospital stocks.
2. Technical explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) extruded as an uncoated monofilament. Lacking interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.
The ⅜ circle needle with a reverse cutting triangular point places the cutting edge on the outer face of the curve, allowing it to penetrate firm, non-distensible tissues without weakening the needle body and reducing the risk of tearing; the fluted body facilitates passage through tissue while minimising trauma. The blue colour of the strand ensures optimal visibility on the surgical field and safe control during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Factory reference | 732DS3610 |
| Reference Cahnos (SKU) | AM732DS3610 |
| Brand / Quality | Premisut – standard quality |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Ribbed blue (high visibility on the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting point, grooved |
| Needle size | 36 mm (model DS36) |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Presentation | Box of 12 units (individual sterile sachets) |
Calibre equivalence (indicative according to USP Pharmacopoeia):
| USP size | Metric size | Approximate diameter |
| 0 | 3.5 | 0.350 – 0.399 mm (non-absorbable suture) |
Premisut DS36 range (⅜ circle needle, triangular reverse cutting grooved point, blue, 75 cm):
| Needle size | USP | Colour | Thread (cm) | Reference |
| DS 36 | 3/0 | Blue | 75 | 732DS3630 (AM732DS3630) |
| DS 36 | 2/0 | Blue | 75 | 732DS3620 (AM732DS3620) |
| DS 36 | 0 | Blue | 75 | 732DS3610 (AM732DS3610 – this product) |
| DS 36 | 1 | Blue | 75 | 732DS3601 (AM732DS3601) |
4. Equivalences and Cross-References
Non-absorbable polypropylene monofilament is one of the most widespread permanent suture families in the surgical market. The reference commercial ranges are PROLENE® (Ethicon / Johnson \u0026 Johnson MedTech), Premilene® (B. Braun) and Surgipro™ II (Medtronic / Covidien). There is no official equivalence table validated by the manufacturer that cross-references this specific reference against other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution. Consult the technical department of Cahnos to validate any equivalence.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene 3/8 DS36, USP 0, blue, 75 cm | P732DS3610 (AMP732DS3610) | Configuration equivalence within the same system | Same needle, calibre, colour and length with superior Prime quality control |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, USP 0, 75 cm | 8690H (FSLX needle ⅜ circle reverse cut, 36 mm) | Comparable by category, not interchangeable 1:1 | Matches in material, gauge, colour, length and reverse cutting needle geometry; commercial pack of 36 units and without the identical fluted finish. |
| B. Braun | Premilene® – uncoated blue monofilament polypropylene | C209xxxx line (1:1 code pending confirmation for USP 0, DS36, 75 cm) | Pending confirmation | Same material and indication; verify needle geometry and size in official catalogue before substituting. |
| Medtronic / Covidien | Surgipro™ II – polypropylene copolymer with polyethylene, blue | SP-690 (USP 0, C-17 needle 3/8 reverse cutting) | Comparable by category, not interchangeable 1:1 | Copolymer material (not pure polypropylene); C-17 needle much shorter than the 36 mm DS36. |
| Atramat® (distributed by Gaesca) | Blue polypropylene, USP 0, 75 cm, 36 mm reverse cutting needle, 3/8 circle. | P3668-75 | Comparable by category, not interchangeable 1:1 | Very close configuration (gauge, colour, length and 36 mm cutting needle); verify official technical data sheet before substitution. |
| Resorba | RESOPREN® – blue PVDF monofilament | 771428 (DS40, USP 0, 75 cm) | Comparable by category | Same approximate needle, gauge and length, but PVDF material (not polypropylene); validate protocol before substituting. |
Technical note: before substituting in a tender or operating theatre, verify one by one: exact gauge, thread length, needle shape and point, needle size, material, colour, surface treatment and regulatory classification (CE/MDR) of the actual product from each manufacturer. The brands cited belong to their respective manufacturers and are mentioned for reference only. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
The 36 mm DS36 needle in ⅜ circle with reverse cutting point is ideal for mid planes and fibrous tissues (skin closure, subcutaneous tissue and wall). USP 0 gauge (metric 3.5) offers an excellent balance between handling and tension, widely used in approximation of soft tissues, vascular ligatures and wall closures. With the same DS36 needle, gauges USP 3/0 (AM732DS3630), USP 2/0 (AM732DS3620) and USP 1 (AM732DS3601) are available; for other needle sizes of the same system, DS30 (AM732DS3010), DS26 (AM732DS2610) and DS40 (AM732DS4010), all in blue and 75 cm. If your purchasing centre requires a superior quality control profile, there is the Prime version with identical configuration (AMP732DS3610). As this is a sterile single-use product, check the integrity of the blister and the expiry date before each procedure, and keep the reference 732DS3610 and the batch number for traceability in the operating theatre. For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews