Description
1. Commercial Introduction
The polypropylene suture Premisut that Cahnos makes available to surgical services, purchasing departments and tenders is the reference solution for the approximation and ligation of soft tissues in high-demand procedures. Its uncoated monofilament design, its highly visible blue colour and its ⅜ circle needle with a 30 mm reverse cutting triangular point (DS 30 profile) offer excellent mechanical behaviour and minimal tissue reaction. It is supplied in a box of 12 units sterilised by ethylene oxide, ready for immediate use in the operating theatre and with batch traceability, facilitating hospital stock management and presentation for public tenders.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin extruded as an uncoated monofilament. As it has no interstices and no wicking effect, it slides very smoothly through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.
The ⅜ circle needle with a reverse cutting triangular point (DS profile, body and point) penetrates firm, inelastic tissues with a clean, stable cut, minimising the risk of tearing; the reverse cutting geometry supports the cutting edge towards the outside of the curve, allowing controlled passage. The ribbed finish of the suture facilitates smooth, consistent delivery during knotting. The product is supplied sterile, is single-use and cannot be re-sterilised.
3. Technical Specifications
| Brand / Quality | Premisut – standard quality |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 4/0 (metric 1.5) |
| Approximate thread diameter | 0.150 – 0.199 mm (indicative, non-absorbable suture according to USP Pharmacopoeia) |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue, fluted (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting point, body and point (DS profile) |
| Needle size | 30 mm (DS 30 profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | 732DS3040 |
| Reference Cahnos (SKU) | AM732DS3040 |
4. Equivalences and Cross-References
The reference 732DS3040 corresponds to the official nomenclature of the Premisut range (DS 30 profile, reverse cutting triangular point, standard quality) and is marketed by Cahnos keeping the factory reference unchanged. Within the Premisut system itself, the DS profile is interchangeable by varying only the needle size or gauge. Non-absorbable monofilament polypropylene is one of the most widespread permanent suture families in the surgical market: the leading commercial ranges are PROLENE® (Ethicon / Johnson & Johnson), Premilene® and Optilene® (B. Braun), Surgipro™ II (Medtronic / Covidien) and SERAPREN® (Serag-Wiessner). There is no official equivalence table validated by the manufacturer cross-referencing this reference against other brands; comparisons between brands are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet and IFU before use in tenders or substitution. Consult the Cahnos technical department to validate any equivalence.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut) | Polypropylene DS 30, USP 4/0, blue, 75 cm (standard quality) | 732DS3040 / AM732DS3040 | Direct product reference | Product analysed in this data sheet |
| Cahnos (Premisut Prime) | Polypropylene DS 30 Prime, USP 4/0, blue, 75 cm | P732DS3040 / AMP732DS3040 | Configuration equivalent within the same system | Same DS 30 needle and USP 4/0 gauge; Prime quality (premium ribbed needle) versus standard |
| Cahnos (Premisut) | Polypropylene DS 24, USP 4/0, blue, 75 cm | 732DS2440 / AM732DS2440 | Functional equivalent within the same system | Same material, gauge, colour and thread length; DS 24 needle of 24 mm (shorter than DS 30), for more superficial planes |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue monofilament polypropylene, USP 4/0, 75 cm, V-4 reverse cutting needle | 8942H | Functional equivalence by specifications, not interchangeable 1:1 without validation | Code verified in authorised distribution sources: matches in material, gauge (4/0), colour and thread length (75 cm); needle geometry/size differs. Commercial presentation in a box of 36 units; confirm IFU and CE/MDR traceability |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – PS-2 Prime reverse cutting (19 mm, 3/8C) and SH-1, USP 4/0, 75 cm | EH7167H · EH7581H | Comparable by category, not interchangeable 1:1 | Same material, gauge, colour and length; needles of 19 mm (PS-2) or ½ circle (SH-1), smaller and of different geometry than DS 30; verify according to tissue |
| B. Braun | Premilene® / Optilene® – polypropylene monofilament (with polyethylene), DS reverse cutting needle | Consult according to gauge and needle size | Comparable by category, pending confirmation of 4/0 code | Copolymer material of polypropylene and polyethylene (not pure polypropylene); verify gauge, geometry and needle size in the official B. Braun catalogue |
| Medtronic (Covidien) | Surgipro™ II – polypropylene copolymer with polyethylene | Consult 4/0 reference | Comparable by category, not interchangeable 1:1 | Same gauge, colour and length; copolymer material and reverse cutting needles of different size; confirm reference and batch against the IFU |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | Consult code according to gauge and needle | Comparable by category, pending confirmation | Blue non-absorbable monofilament polypropylene; verify gauge, geometry and needle size with the distributor before substituting |
| GIMA | TRULENE – blue monofilament polypropylene, USP 4/0, 75 cm, 3/8 reverse cutting | Consult 4/0 DS30 reference | Comparable by category, not interchangeable 1:1 | Equivalent declared by the distributor against PROLENE®; verify needle size (19 mm references) and presentation |
Mandatory technical note: there is no equivalence table validated by the manufacturer cross-referencing this reference with other brands; comparisons with PROLENE®, Premilene®, Optilene®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or instructions for use (IFU) before use in tenders or direct substitution.
5. Selection tips and variants of interest
Tissue to suture: the ribbed DS reverse cutting needle is suitable for soft and flat tissues requiring firm, controlled penetration (skin, fascia, subcutaneous tissue, cardiovascular surgery, ophthalmology and neurosurgery). For lax or vascular tissues, consider conical point profiles (HR) from the same Premisut range.
Gauge: the USP 4/0 (metric 1.5) is a fine gauge, ideal for delicate planes and fine tissues; with the same DS 30 needle it is available in versions 3/0 (AM732DS3030), 2/0 (AM732DS3020), USP 0 (AM732DS3010) and USP 1 (AM732DS3001) for greater mechanical requirements. In Prime quality, the AMP732DS3040 version maintains the same configuration with a premium ribbed finish.
Needle size: the 30 mm DS 30 is an intermediate needle, ideal for medium suture planes and areas of limited access; for more superficial planes it is available with the DS 24 (AM732DS2440) or DS 19 (AM732DS1940) in gauge 4/0, and for wider fields with the DS 36 or DS 40 in other gauges.
Sterility verification: single-use product sterilised by ethylene oxide; check the integrity of the blister and the expiry date before each use and keep the reference 732DS3040 and the batch number for traceability in the operating theatre and in the event of a claim. For B2B volume conditions, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.