Description
1. Commercial Introduction
The polypropylene suture PREMISUT PRIME is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating tissue with full control. This presentation in gauge USP 0, with a ⅜ circle needle with a triangular reverse cutting grooved point of 30 mm (DS 30 Prime profile) and a blue thread of 75 cm, is indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
It is supplied sterile and ready for the operating theatre in a box of 12 units with batch traceability, facilitating hospital stock management and presentation for public tenders. Available at Cahnos under the factory reference P732DS3010 (SKU AMP732DS3010), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, supporting the wound for more than three months.
The DS 30 Prime needle (⅜ circle, triangular reverse cutting grooved point of 30 mm) penetrates soft and poorly distensible tissues with a clean and stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage. The grooved finish of the needle body facilitates smooth delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Main technical data sheet
| Parameter | Specification |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 0 (metric EP 3.5; indicative diameter 0.35–0.399 mm); in accordance with USP and European Pharmacopoeia gauges |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue (high visibility in the field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular reverse cutting point, grooved body |
| Needle size | 30 mm (DS 30 Prime profile) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DS3010 |
| Reference Cahnos (SKU) | AMP732DS3010 |
DS family (⅜ circle reverse cutting grooved) in USP 0 gauge, blue
| Needle profile | USP | Presentation | Reference |
| DS 30 Prime | 0 | 1 × 75 cm | P732DS3010 / AMP732DS3010 (this product) |
| DS 30 Prime | 0 | 2 × 75 cm | P732DS3010.2 / AMP732DS3010.2 |
| DS 36 Prime | 0 | 2 × 75 cm | P732DS3610.2 / AMP732DS3610.2 |
| DS 40 Prime | 0 | 1 × 75 cm | P732DS4010 / AMP732DS4010 |
| DS 40 Prime | 0 | 2 × 75 cm | P732RDS4010.2 / AMP732RDS4010.2 |
4. Equivalences and Cross-References
The reference P732DS3010 corresponds to the official nomenclature of the Premisut Prime range (DS 30 Prime profile, single 75 cm thread). Cahnos markets the product keeping the factory reference without altering characters: no digit should be added, removed or reordered when ordering or bidding. The DS needle profile (reverse cutting) is only interchangeable within the Premisut system itself by varying the needle size or gauge.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range (Cahnos) | Polypropylene DS 30 Prime, USP 0, blue, 2 × 75 cm | P732DS3010.2 / AMP732DS3010.2 | Configuration equivalent within the same system | Same DS 30 needle and USP 0 gauge; presentation changes to 2 threads of 75 cm |
| Premisut range (Cahnos) | Polypropylene DS 30, USP 0, blue, 75 cm (standard quality) | AM732DS3010 (REF. 732DS3010) | Functional category equivalent | Same geometry, gauge and length; standard quality, needle without grooved body |
| Premisut Prime range (Cahnos) | Polypropylene DS 36 Prime, USP 0, blue, 2 × 75 cm | AMP732DS3610.2 | Comparable within the same system | Same gauge and presentation; DS needle of 36 mm versus 30 mm |
| Premisut Prime range (Cahnos) | Polypropylene DS 40 Prime, USP 0, blue, 2 × 75 cm | AMP732RDS4010.2 | Comparable within the same system | Same gauge and presentation; DS needle of 40 mm versus 30 mm |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, USP 0, 75 cm, FSLX 3/8 circle reverse cutting needle | 8690H | Comparable by category, not interchangeable 1:1 | It matches in material, gauge, colour, length and 3/8 reverse cutting geometry; the FSLX measures 36–40 mm compared to the 30 mm of the DS 30 Prime profile. Presentation in a box of 36 units; confirm batch and CE/MDR traceability against the IFU. |
| B. Braun (Aesculap) | Premilene® / Optilene® – blue polypropylene monofilament, DS 3/8 reverse cutting needle | C2090199 / C3090199 – pending confirmation of 1:1 code for DS 30 USP 0 | Comparable by category / pending confirmation | Same blue polypropylene base; the exact combination of reverse cutting needle 30 mm + USP 0 + 75 cm has not been verified in public sources. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene copolymer with polyethylene, blue, USP 0, 75 cm, C-17 3/8 circle reverse cutting needle | SP-690 | Comparable by category, not interchangeable 1:1 | Copolymer material (not pure polypropylene); C-17 needle with its own geometry; box of 36 units and a single thread |
| Serag-Wiessner | SERAPREN® BLAU – blue polypropylene monofilament, USP 0 (EP 3.5), 75 cm, DS-30 3/8 reverse cutting needle | CO353416 | Comparable by category, not interchangeable 1:1 | Same material, gauge, colour and length with DS-30 needle of 30 mm (homologous profile); verify batch, presentation and traceability against the IFU. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®/Optilene®, Surgipro™ II or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
- Tissue to suture: the grooved reverse cutting DS needle is suitable for soft and flat tissues that require firm and controlled penetration (skin, fascia, subcutaneous, cardiovascular surgery, ophthalmology and neurosurgery). For lax or vascular tissues, consider round point profiles (HR) from the same Premisut Prime range.
- Needle size: the DS 30 of 30 mm is an intermediate needle, ideal for medium suture planes and areas of reduced access; for wider fields, the DS 36 (AMP732DS3610.2) and DS 40 (AMP732RDS4010.2) are available in the same USP 0 gauge.
- Gauge: USP 0 (metric 3.5) offers medium-high tension for soft tissues and ligatures; for planes of lower mechanical demand, consider USP 2/0 (AMP732DS3020) or USP 3/0 (AMP732DS3030) with the same DS 30 needle.
- Presentation: the 2 × 75 cm version (AMP732DS3010.2) reduces the opening of packaging per intervention compared to this single-thread one, being practical for continuous sutures or multiple passes; the standard version AM732DS3010 is the economical alternative of the same configuration.
- Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each intervention and keep the reference P732DS3010 and the batch number for traceability in the operating theatre and in case of complaint. For B2B volume conditions, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews