Description
1. Commercial Introduction
The Premisut Prime polypropylene suture from Cahnos is the reference choice for surgical departments, purchasing centres and tenders that require a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction. This presentation incorporates a ⅜ circle needle with a 12 mm reverse cutting triangular point (DS12 Prime profile), USP 7/0 gauge and a 45 cm strand in high-visibility blue: an ultra-fine configuration designed for superficial planes, microsurgery, very delicate tissues, ligatures and cardiovascular, ophthalmology and neurosurgery procedures.
Supplied sterile, ready for single use, with batch traceability, which facilitates hospital stock management and submission to public tenders. Price per box of 12 units.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) supplied as an uncoated monofilament: as it has no interstices or wicking effect, it slides very smoothly through tissue, does not promote bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength over time, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.
The DS12 Prime needle (⅜ circle, 12 mm reverse cutting triangular point) penetrates soft, non-distensible tissues with a clean, stable cut: the reverse cutting geometry supports the cutting edge towards the outside of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage, even in restricted access planes or microsurgery. The USP 7/0 gauge (EP metric 0.5) is one of the finest in the range, ideal for precision sutures on delicate structures. Sterilised by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut Prime range (Cahnos S.L.).
| Parameter | Specification |
|---|---|
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament, non-channeled |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 7/0 (metric EP 0.5); conforming to USP gauges and European Pharmacopoeia |
| Thread diameter | 0.050 – 0.069 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture) |
| Thread length | 45 cm (1 strand per unit) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Reverse cutting triangular point, DS profile |
| Needle size | 12 mm (DS12 Prime profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P731DS1270 |
| Reference Cahnos (SKU) | AMP731DS1270 |
Premisut Prime DS12 family (⅜ circle needle, reverse cutting triangular point, blue):
| Needle profile | USP size | Thread | Reference |
|---|---|---|---|
| DS12 Prime | 6/0 | 45 cm | P731DS1260 / AMP731DS1260 |
| DS12 Prime | 7/0 | 45 cm | P731DS1270 / AMP731DS1270 (this product) |
| DS12 Prime | 5/0 | 45 cm | P731DS1250 / AMP731DS1250 |
| DS10 Prime | 6/0 | 45 cm | P731DS1060 / AMP731DS1060 |
| DS16 Prime | 6/0 | 45 cm | P731DS1660 / AMP731DS1660 |
| DS16 Prime | 6/0 | 75 cm | P732DS1660 / AMP732DS1660 |
4. Equivalences and Cross-References
Reference P731DS1270 corresponds to the official nomenclature of the Premisut Prime range (DS12 Prime profile, single 45 cm strand, USP 7/0 gauge). Cahnos markets the product keeping the factory reference unchanged. There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene DS12 Prime, USP 6/0, blue, 45 cm | AMP731DS1260 | Direct range equivalent | Same DS12 needle, quality and length; 6/0 gauge with larger diameter for microsurgery |
| Cahnos (Premisut Prime) | Polypropylene DS12 Prime, USP 5/0, blue, 45 cm | AMP731DS1250 | Direct range equivalent | Same DS12 needle and length; 5/0 gauge for delicate tissues with greater resistance |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, 7/0, 45 cm, P-1 ⅜ circle precision reverse cutting needle, 11 mm | 8696G | Comparable by category, not interchangeable 1:1 | Code verified in official Ethicon catalogue and authorised distribution: same material, gauge, colour and length; P-1 needle of 11 mm versus DS12 of 12 mm. Confirm CE/MDR traceability against IFU |
| Medtronic (Covidien) | Surgipro™ II – polypropylene/polyethylene copolymer blue monofilament, 7/0, 45 cm, P-10 ⅜ circle premium reverse cutting needle | SP1696G | Comparable by category, not interchangeable 1:1 | Code verified in official Medtronic catalogue and authorised distribution: same needle configuration and gauge; copolymer material (not pure polypropylene) and shorter P-10 needle length, pending confirmation in IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 7/0 | 7/0 code not verified in this consultation | Comparable by category, not verified | Same base material and gauge confirmed in official catalogue (USP range 1 to 10/0); confirm needle geometry and exact reference in official catalogue before use |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | 7/0 code not verified in this consultation | Comparable by category, not verified | Same base material confirmed (blue polypropylene monofilament, USP 8/0 to 1); confirm code, needle and presentation in official catalogue before use |
Mandatory technical note: there is no equivalence table validated by the manufacturer cross-referencing this reference with other brands; comparisons with PROLENE®, Surgipro™ II, Premilene® or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or substitution. The DS12 reverse cutting needle geometry is only safely interchangeable within the Premisut system itself. Consult the Cahnos technical department to validate any equivalence before use.
5. Selection tips and variants of interest
Tissue to suture: the DS reverse cutting needle is suitable for soft tissues and skin planes requiring firm, controlled penetration in very restricted access areas (cardiovascular surgery, ophthalmology, neurosurgery and general surgery). The USP 7/0 gauge (metric 0.5) is of maximum fineness for microsurgery and microcosmetics. For lax or vascular tissues, consider conical point profiles (DR/HR) from the same Premisut Prime range.
Needle size: the 12 mm DS12 is compact, ideal for superficial planes and limited surgical fields. If the protocol requires an even shorter needle in 6/0, the DS10 (AMP731DS1060) is available; if a longer needle is required in the same 6/0 gauge, the DS16 (AMP731DS1660 / AMP732DS1660) or DS19 (AMP731DS1960).
Alternative gauges with the same DS12 needle: USP 6/0 (AMP731DS1260) and USP 5/0 (AMP731DS1250) allow supplier consolidation across the entire range of precision permanent sutures.
Length and presentation: this 45 cm reference is a compact, economical presentation for short passes or limited fields; for sutures with longer reach, 75 cm versions of the range are available (e.g. AMP732DS1660) and, as a cost alternative, the standard Premisut quality that maintains needle and gauge.
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep reference P731DS1270 and the batch number for traceability in the operating theatre. For special B2B conditions by volume, hospital supply agreements or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews