Description
1. Commercial Introduction
The PREMISUT PRIME polypropylene suture is the reference choice for surgery departments, purchasing centres and tenders looking for a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating tissue with full control. This presentation in USP 4/0 calibre, with a ⅜ circle reverse cutting triangular point needle of 12 mm (DS 12 Prime profile) and a 75 cm thread in blue, is specially indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery, cuticular surgery and soft tissue approximation.
Supplied sterile and ready for single use in a box of 12 units with batch traceability, facilitating hospital stock management and presentation to public tenders. Available at Cahnos under the factory reference P732DS1240 (SKU AMP732DS1240), kept unchanged.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, does not favour bacterial adhesion or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength over time, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, supporting the wound for more than three months.
The DS 12 Prime needle (⅜ circle, 12 mm reverse cutting triangular point, non-ribbed) penetrates soft and poorly distensible tissues with a clean, stable cut: the reverse cutting geometry supports the cutting edge towards the outer part of the curve, which reduces the risk of tearing in firm tissues and allows controlled passage. Its contained 12 mm length makes it ideal for reduced suture planes, short incisions and delicate access areas. Sterilisation by ethylene oxide (EO); single-use product, not resterilisable.
3. Technical Specifications
| Parameter | Specification |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament, non-grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 4/0 (metric EP 1.5); conforms to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm per unit |
| Thread colour | Identification blue (phthalocyanine) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Reverse cutting triangular point (DS profile) |
| Needle size | 12 mm (DS 12 Prime profile) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DS1240 |
| Reference Cahnos (SKU) | AMP732DS1240 |
DS family (⅜ circle reverse cutting) in DS 12 Prime profile:
| Needle profile | USP | Presentation | Reference |
| DS 12 Prime | 4/0 | 1 × 75 cm | P732DS1240 |
| DS 12 Prime | 5/0 | 1 × 45 cm | P731DS1250 |
| DS 12 Prime | 6/0 | 1 × 45 cm | P731DS1260 |
| DS 12 Prime | 7/0 | 1 × 45 cm | P731DS1270 |
4. Equivalences and Cross-References
The reference P732DS1240 corresponds to the official nomenclature of the Premisut Prime range (DS 12 Prime profile, single 75 cm thread). Cahnos markets the product keeping the factory reference unchanged; the DS needle profile (reverse cutting) is only interchangeable within the Premisut system itself, varying needle size or gauge. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tender or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range (Cahnos) | Polypropylene DS 12 Prime, USP 4/0, blue, 75 cm | P732DS1240 / AMP732DS1240 | Direct product reference | Product analysed in this data sheet |
| Premisut Prime range (Cahnos) | Polypropylene DS 12 Prime, USP 4/0, blue, 45 cm | P731DS1240 | Configuration equivalent within the same system | Same needle and gauge; changes presentation to 45 cm |
| Premisut range (Cahnos) | Polypropylene DS 16, USP 4/0, blue, 75 cm | 732DS1640 | Comparable within the same system | Same gauge and length; 16 mm needle vs 12 mm |
| Premisut Prime range (Cahnos) | Polypropylene DS 19 Prime, USP 4/0, blue, 75 cm | P732DS1940 | Comparable within the same system | Same gauge and length; 19 mm needle vs 12 mm |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, USP 4/0, 3/8 circle reverse cutting needle 13 mm, 45 cm | NW879 | Functional equivalence by specifications (no official cross-reference table) | Matches in material, gauge, colour and needle geometry (3/8, reverse cutting); differ in needle size (13 mm vs 12 mm) and thread length (45 cm vs 75 cm). Confirm presentation and lot against IFU |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® PS-2 – blue polypropylene, USP 4/0, 3/8 circle precision reverse cutting needle 19 mm (cuticular/plastic) | 8682G | Comparable by category | Same polypropylene base and gauge; 19 mm precision needle aimed at cuticular use, not 1:1 interchangeable with DS 12 |
| B. Braun | Premilene® / Optilene® (blue polypropylene monofilament, Easyslide needles) | C20xxxx line – pending confirmation of 1:1 code for DS 12 USP 4/0 | Comparable by category / pending confirmation | Same blue polypropylene base; the exact combination of 12 mm reverse cutting needle + USP 4/0 + 75 cm has not been verified in public sources |
| Medtronic (Covidien) | Surgipro™ II (polypropylene with polyethylene, blue monofilament) | SP series – pending confirmation for USP 4/0 | Comparable by category / pending confirmation | Copolymer with polyethylene; confirm reference and needle geometry against IFU |
| Serag-Wiessner | SERAPREN® (blue polypropylene monofilament, USP 8/0 to 0) | Consult code according to gauge and needle | Comparable by category / pending confirmation | Non-absorbable blue polypropylene monofilament; verify gauge, size and needle geometry with the distributor |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®/Optilene®, Surgipro™ or SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tender. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Tissue to suture: the DS 12 mm needle is a short reverse cutting needle, suitable for soft tissues and reduced suture planes requiring firm and controlled penetration (skin, cuticular, ophthalmology, microsurgery and cardiovascular surgery). For lax or vascular tissues, consider round point profiles (HR or DR) from the same Premisut Prime range.
Needle size: the DS 12 mm is reserved for delicate access areas; if you need greater reach in the same USP 4/0 gauge, you have the DS 16 (732DS1640) or the DS 19 Prime (P732DS1940) with 75 cm thread.
Gauge: USP 4/0 (metric EP 1.5) offers medium-low tension, indicated for soft tissues under low tension and superficial planes; for more demanding planes consider USP 3/0 (P732DS1930) or USP 2/0 (P732DS1920) within the same DS family.
Presentation: this single-thread format of 75 cm is the standard in the operating theatre; if you need to reduce packaging openings, the Premisut Prime range offers double-thread versions (2 × 75 cm) in other DS profiles.
Sterility verification: product sterilised by ethylene oxide, single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DS1240 and the batch number for traceability in the operating theatre and in the event of a claim.





Reviews