Description
1. Commercial Introduction
The Premisut Prime polypropylene suture is the reference choice for surgical departments, purchasing centres and tenders that need a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This USP 4/0 presentation incorporates a ½ circle needle with cylindrical body and trocar point (Tapercut) of 17 mm (HRT 17 Prime profile) and a 75 cm blue grooved strand: a classic and versatile configuration, highly valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
It is supplied sterile and ready for single use in a box of 12 units with batch traceability. Available at Cahnos under the factory reference P732HRT1740 (SKU AMP732HRT1740), kept without altering characters.
2. Technical Explanation
Polypropylene is a linear synthetic polyolefin presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not promote bacterial adherence and minimises thread extrusion. As it is non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HRT needle (½ circle, cylindrical body) with trocar or Tapercut point combines the firm penetration of a cutting point with a non-cutting body: it passes through slightly fibrous tissues, vascular adventitia or calcified walls with less resistance and without tearing the suture bed. The blue grooved strand guarantees optimal visibility and better knot grip on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not resterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / line | Premisut Prime (polypropylene, premium range) |
| Material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface (knot grip) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 4/0 (metric EP 1.5); conforms to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Trocar (Tapercut), HRT profile |
| Needle size | 17 mm (HRT 17 Prime) |
| Configuration | Single needle (1 × HRT 17) |
| Manufacturing quality | Prime (premium needle finish) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732HRT1740 |
| Reference Cahnos (SKU) | AMP732HRT1740 |
4. Equivalences and Cross-References
Blue non-absorbable polypropylene monofilament is one of the most standardised permanent suture families on the market (“Prolene” type). There is no official equivalence table validated by the manufacturer that cross-references the P732HRT1740 reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1 without prior technical validation against each manufacturer’s technical data sheet and IFU.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut Prime (Cahnos) | Polypropylene Prime – ½ circle trocar point HRT 17, 4/0 blue, 75 cm | P732HRT1740 / AMP732HRT1740 | Exact reference equivalence (identical) | Official reference of the product analysed in this data sheet. |
| Premisut Prime (Cahnos) | Polypropylene HRT 17 Prime, USP 3/0, blue, 75 cm | P732HRT1730 / AMP732HRT1730 | Direct equivalent within the same system | Same HRT 17 needle, colour and length; the gauge changes to USP 3/0. |
| Premisut Prime (Cahnos) | Polypropylene HRT 17 Prime, USP 5/0, blue, 75 cm | P732HRT1750 / AMP732HRT1750 | Direct equivalent within the same system | Same HRT 17 needle, colour and length; USP 5/0 gauge for finer tissues. |
| B. Braun (Aesculap) | Premilene® – blue polypropylene, 4/0 (1.5), 75 cm, HRT 17 needle, ½ circle | GTIN 04046963632243 (GUDID); catalogue model C2090315 (pending confirmation) | Comparable at category level (not interchangeable 1:1) | Material, gauge (EP 1.5), 75 cm length and ½ circle HRT 17 needle match; confirmed in GUDID database (PREMILENE 4/0 (1.5) 75CM HRT17 (M)). Needle finish and commercial presentation differ (box of 12 units vs. B. Braun packaging); verify IFU. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 4-0, 75 cm, V-4 TAPERCUT needle of 17 mm, ⅜ circle | F2828H (verified in Ethicon EMEA catalogue) | Comparable at category level (not interchangeable 1:1) | Material, gauge, colour, length (75 cm), trocar point (Tapercut) and needle size (17 mm) match; the arc differs: ⅜ circle vs. ½ circle, and bi-directional presentation in a box of 36 units. Confirm contralateral profile by IFU. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene, 4-0, 75 cm, RB-1 needle of 17 mm, ½ circle, taper point | 8871H (verified at authorised distributors) | Comparable at category level (not interchangeable 1:1) | Material, gauge, colour, length and needle size (17 mm, ½ circle) match, but the RB-1 has a taper point (Taper Point) vs. the HRT’s trocar point (Tapercut): different penetration profile for fibrous or calcified tissue. |
| Medtronic (Covidien) | Surgipro™ II – copolymer of polypropylene with polyethylene, blue, 4-0, 75 cm, CV-23 needle, ½ circle, conical point | VP-871-X (verified at authorised distributors) | Comparable at category level (not interchangeable 1:1) | Same gauge, colour and length; CV-23 needle with taper point (Taper Point). Copolymer material (polypropylene with polyethylene), composition different from the Premisut strand. Confirm point profile by IFU. |
| B. Braun | Optilene® – copolymer of polypropylene with polyethylene, blue, 4/0 (1.5), 75 cm, HR17 needle conical point | C3090013 (verified in B. Braun catalogue) | Comparable at category level (not interchangeable 1:1) | Gauge, colour and length match; but HR17 needle with taper point (Taper Point) and copolymer material (not pure polypropylene), so it is not interchangeable 1:1. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; before substituting in a tender, protocol or operating theatre, verify one by one the exact gauge, thread length, needle shape and point (trocar vs. taper), needle size, material (pure polypropylene vs. copolymer) and regulatory classification (CE/MDR) of each manufacturer’s actual product. Consult the Cahnos technical department before using this information in tendering or direct substitution.
5. Selection tips and variants of interest
- Trocar point (Tapercut): choose this configuration when the tissue presents some resistance or fibrosis (vascular, cardiovascular, adventitia); the cutting point facilitates entry and the cylindrical body minimises trauma. For very friable tissues, consider the taper point (Taper Point) variant of the same family.
- Gauge: USP 4/0 (metric 1.5) is very versatile for vascular, cardiovascular and general soft tissue surgery. If greater strength is required, the same HRT 17 needle is available in USP 3/0 (AMP732HRT1730); for finer tissues, 5/0 (AMP732HRT1750).
- Needle length: the 17 mm HRT is ideal for medium-depth surgical fields and delicate tissues. For deeper approaches, consider the HRT 25 (AMP732HRT2530/2540) or HRT 36 (AMP732HRT3620) needles from the same line.
- Double needle: for continuous suture techniques or anastomosis with two armed ends, consult the 2xHRT 17 configuration in the range (which avoids re-threading and optimises surgical time).
- Prime range: the Premisut Prime line maintains the geometry of the standard version with an improved needle finish; useful when the protocol requires premium penetration quality.
- Prior verification: always confirm the full reference (HRT 17 needle, gauge 4/0 and length 75 cm) on the packaging before use in the operating theatre; check the integrity of the blister and the expiry date. Single-use product, not re-sterilisable.





Reviews