Description
1. Commercial Introduction
The polypropylene suture Premisut Prime is the reference choice for surgical departments, purchasing centres and tenders looking for a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation incorporates a double ½ circle trocar point (Tapercut) needle of 25 mm (profile 2xHRT25 Prime), gauge USP 0 (metric EP 3.5) and a blue non-grooved strand of 90 cm, a configuration especially indicated for approximation and ligation of soft tissues under some tension, as well as for cardiovascular surgery, ophthalmology and neurosurgery.
It is supplied sterile, ready for immediate use, in a box of 12 units with individual pouches and batch traceability. Available at Cahnos under the factory reference P733HRT2510-2 (SKU AMP733HRT2510-2), kept with characters unchanged.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: lacking interstices and wick effect, it offers very smooth passage through tissue, does not promote bacterial adhesion or sinus formation in wounds at risk of contamination, and minimises thread extrusion. As it is non-absorbable, it is not degraded by tissue enzymes: it becomes gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HRT needle (½ circle, cylindrical body) with trocar point or Tapercut combines the firm penetration of a cutting point with a non-cutting body, allowing it to pass through slightly fibrous tissues, vascular adventitia or fascia with less resistance and without tearing the suture bed. The double needle format (2x) allows continuous suture techniques and anastomosis with two armed ends, without re-threading, optimising surgical time. The blue non-grooved strand ensures optimal visibility over the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / line | Premisut Prime (premium range, polypropylene) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Non-grooved monofilament |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Identification blue |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Trocar (Tapercut), HRT profile |
| Needle size | 25 mm (2xHRT 25) |
| Configuration | Double needle (2 × HRT) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P733HRT2510-2 |
| Reference Cahnos (SKU) | AMP733HRT2510-2 |
3.2. Premisut HRT 25 family (1/2 circle, cylindrical body, trocar point) and range variants
| Needle profile | Presentation | Reference |
|---|---|---|
| 2xHRT 25 Prime | 2 × 90 cm, USP 0 (product analysed) | P733HRT2510-2 / AMP733HRT2510-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 2/0 | P733HRT2520-2 / AMP733HRT2520-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 3/0 | P733HRT2530-2 / AMP733HRT2530-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 4/0 | P733HRT2540-2 / AMP733HRT2540-2 |
| HRT 25 Prime (single needle) | 1 × 75 cm, USP 4/0 | P732HRT2540 / AMP732HRT2540 |
| HRT 25 Prime (single needle) | 1 × 75 cm, USP 3/0 | P732HRT2530 / AMP732HRT2530 |
4. Equivalences and Cross-References
The reference P733HRT2510-2 corresponds to the official nomenclature of the Premisut Prime range (profile 2xHRT 25 Prime, double needle, gauge USP 0, blue thread 90 cm). There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut Prime (Cahnos) | Polypropylene 1/2 circle trocar point 2xHRT25, USP 0, blue, 90 cm | P733HRT2510-2 / AMP733HRT2510-2 | Exact reference equivalence (identical) | Official reference of the analysed product |
| Premisut Prime (Cahnos) | Polypropylene 1/2 circle trocar point 2xHRT25, USP 2/0, blue, 90 cm | P733HRT2520-2 / AMP733HRT2520-2 | Configuration equivalent within the same system | Same 2xHRT 25 needle and length; gauge changes to USP 2/0 |
| Premisut Prime (Cahnos) | Polypropylene 1/2 circle tapercut 2xHRT25, USP 3/0, blue, 90 cm | P733HRT2530-2 / AMP733HRT2530-2 | Configuration equivalent within the same system | Same 2xHRT 25 needle and length; gauge changes to USP 3/0 |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue monofilament polypropylene, 0, 90 cm, double needle V-7 TAPERCUT 1/2 circle 26 mm | 8978H (verified in Ethicon catalogue and authorised distribution; box of 36 units) | Comparable at category level (not interchangeable 1:1) | Matches material, gauge, colour, double needle, trocar point 1/2 circle and length (90 cm); V-7 needle of 26 mm vs HRT of 25 mm and packaging of 36 units. Confirm IFU and CE/MDR traceability |
| Medtronic (Covidien) | Surgipro™ II – monofilament of polypropylene with polyethylene, blue, 0, 90 cm, KV-7 tapercutting needle 1/2 circle 26 mm | VP978 (verified in authorised distribution; box of 36 units) | Comparable by category, not interchangeable 1:1 | Copolymer material (not pure polypropylene); KV-7 needle of 26 mm vs HRT of 25 mm and packaging of 36 units. Verify IFU |
| B. Braun (Aesculap) | Premilene® – blue monofilament polypropylene, 0, 90 cm | Series C209xxxx – pending confirmation of 1:1 code for trocar point USP 0 | Comparable by category / pending confirmation | Same blue polypropylene base, gauge and length; verify in official data sheet the needle profile (HR conical point vs. HRT trocar) and the measurement in mm |
| Degasa | DemeLENE™ – blue non-absorbable polypropylene | Pending confirmation (no presentation 0 trocar 90 cm 1:1 was found) | Comparable by category / pending confirmation | Range with varied gauges and geometries (tapered, reverse cutting); confirm trocar point, double needle and length in official data sheet |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Surgipro™ II, Premilene® or DemeLENE™ are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Trocar point (Tapercut): choose this configuration when the tissue presents some resistance or fibrosis (vascular, cardiovascular, fascia); the cutting point facilitates entry and the cylindrical body minimises trauma. For very friable tissues consider the conical point (Taperpoint) variant from the same Premisut family.
Gauge USP 0: offers high mechanical support, ideal for ligatures and approximation of moderately tense tissues or those with higher strength requirements. If you need finer gauges for microsurgery or delicate tissue, the same 2xHRT25 needle is available in USP 2/0 (P733HRT2520-2), USP 3/0 (P733HRT2530-2) or USP 4/0 (P733HRT2540-2).
Needle length: the 25 mm HRT offers a good balance between control and penetration in deep fields. For deeper approaches consider the 30 mm HRT (e.g. AMP733HRT3030-2, USP 3/0) and for smaller fields the 17 mm HRT (AMP733HRT1730-2, USP 3/0).
Presentation: the double needle version 2 × 90 cm optimises thread utilisation and facilitates continuous sutures and anastomosis; if your protocol prefers a single needle, the variant P732HRT2540 (1 × 75 cm, USP 4/0) is available.
Sterility verification: product sterile by ethylene oxide, single-use; check the integrity of the blister and the expiry date before each use and keep the reference P733HRT2510-2 and the batch number for traceability in the operating theatre and in case of complaint.





Reviews