Description
Introduction
The polypropylene suture Premisut Prime is the high-precision solution your operating theatre needs for procedures that demand superior reliability and performance. Its uncoated monofilament configuration offers optimal glide through tissues, minimal inflammatory reaction and prolonged tensile strength that maintains wound approximation for months.
Technical product explanation
Polypropylene is a synthetic linear polyolefin processed into isotactic crystalline monofilament. This structure provides high ductility (the thread can stretch up to 30% before breaking, accommodating postoperative swelling without strangulating tissue), excellent knot security and gradual encapsulation by fibrous tissue that preserves structural integrity for extended periods. The HRT 36 needle combines a cylindrical body with a trocar point (tapercut), allowing dense or fibrous tissue to be traversed with clean, controlled penetration, minimising tearing. Its ½ circle geometry facilitates handling in deep planes and stitch control, in both open and minimally invasive surgery.
Technical specifications
| Parameter | Value |
|---|---|
| Material | Uncoated polypropylene monofilament |
| Absorption | Non-absorbable (permanent, gradual encapsulation) |
| Gauge | USP 2/0 (metric 3.0 approx.) |
| Thread colour | Ribbed blue |
| Thread length | 75 cm |
| Needle shape | ½ circle |
| Needle type | Cylindrical body, trocar point (tapercut) HRT |
| Needle size | 36 mm |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 12 sterile single-use units |
| Quality | Prime (high precision and needle hardness) |
| Manufacturer reference | 732HRT3620 |
Equivalences and cross-references
No external reference matching all fields (same HRT 36 tapercut needle, USP gauge 2/0, blue thread 75 cm) has been found in the official catalogues consulted. The following references are comparable at category level, not interchangeable 1:1; always verify the point geometry, gauge and length before substituting.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson) | Prolene® Polypropylene, V-7 tapercut ½ circle needle | 8977H | Comparable by category | Same USP size 2/0 and tapercut point, but V-7 needle of 26 mm and thread of 90 cm. Verified in official Ethicon catalogue. |
| Ethicon (Johnson & Johnson) | Prolene® Polypropylene, CT-1 taper point ½ circle needle | 8423H | Comparable by category | Same USP gauge 2/0, 36 mm needle and 75 cm thread, but conical point (taper point), not trocar. Verified in official Ethicon catalogue. |
| Medtronic (Covidien) | Surgipro™ II Polypropylene, KV-7 tapercutting needle ½ circle | VP977 | Comparable by category | Same USP gauge 2/0 and tapercut point, but KV-7 needle of 26 mm and 90 cm thread. Verified in official Medtronic catalogue. |
| DemeTECH | DemeLENE® Polypropylene, DCT-2 needle round body ½ circle | PM292026B1P | Comparable by category | Same USP gauge 2/0 and 75 cm thread, but DCT-2 needle of 26 mm round body (not tapercut). Verified in official DemeTECH store. |
| B.Braun | Premilene® Polypropylene, HRC22 (M)CV needle | UDI-DI 04046963639709 | Comparable by category | Same USP gauge 2/0 and 75 cm thread, but HRC22 needle of 22 mm (premium cardiovascular needle, not 36 mm tapercut). Verified in GUDID/FDA. |
Important: there is no equivalence table validated by the manufacturer Premisut for this reference; consult our technical department before using these cross-references in tenders or closed surgical protocols.
Selection tips and variants of interest
Before substituting this suture for another reference, always verify: point geometry (trocar/tapercut vs. conical), USP gauge, thread length and needle size. In our range, you have the same HRT 36 Prime configuration in USP gauge 0 (ref. AMP732HRT3610) or in the standard range (refs. AM732HRT3620 and AM732HRT3610). For approaches with a conical needle, consider refs. AMP732HR3020 (HR30, 2/0) and AMP732HR3520 (HR35, 2/0). You may also be interested in the double-needle version of 13 mm for microsurgery (ref. AMP732HR1360-2, USP 6/0).





Reviews