Description
1. Commercial Introduction
The Premisut Prime polypropylene suture with double needle ½ circle trocar point (tapercut) 17 mm is the reference solution for surgery departments seeking a high-performance non-absorbable thread with predictable behaviour and minimal tissue reaction. Presented in USP 2/0 gauge, blue colour and 90 cm thread, it allows standardisation in soft tissue approximation and ligation procedures, as well as in demanding specialties such as cardiovascular surgery, ophthalmology and neurosurgery. It is supplied sterile, ready for immediate use in the operating theatre, in a box of 12 units with individual pouches and full batch traceability.
2. Technical explanation
The thread is made of isotactic polypropylene, a linear synthetic polymer (polyolefin) with high chemical inertness, presented as an uncoated monofilament. Being non-absorbable, it does not degrade or lose strength due to enzymatic action of the body: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase. Its uncoated monofilament structure reduces tissue drag, avoids the saw effect on delicate tissues and minimises bacterial adherence.
The ½ circle needle with cylindrical body and trocar point (tapercut) combines the penetration of a three-edged cutting point with the minimal aggression of a round-point needle: it passes through slightly fibrous tissues, vascular adventitia or calcified walls with less resistance and without tearing the suture bed. The double needle configuration (2×HRT17) allows continuous sutures or anchors with two armed ends without re-threading, optimising surgical time in confined fields. The blue colour ensures optimal visibility of the thread on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / line | Premisut Prime (premium range, improved finish needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 2/0 (metric EP 3); approx. diameter 0.30–0.34 mm |
| Thread length | 90 cm (1 thread per unit, armed at both ends) |
| Thread colour | Blue (high visibility in the surgical field) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body / tip | Cylindrical body, trocar (tapercut) point, non-grooved |
| Needle configuration and size | Double needle 2×HRT 17, 17 mm (stainless steel) |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Factory reference | P733HRT1720-2 |
| SKU Cahnos | AMP733HRT1720-2 |
Gauge equivalence (indicative according to USP/EP Pharmacopoeia):
| USP size | Metric size | Approximate diameter |
| 2/0 | 3 | 0.30 – 0.34 mm (non-absorbable suture) |
4. Equivalences and Cross-References
The blue non-absorbable monofilament polypropylene is one of the most standardised permanent suture families on the market (commercially known as the “Prolene” type). There is no official equivalence table validated by the manufacturer that cross-references this specific reference against other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution. Always consult the technical department of Cahnos to validate any equivalence.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene 1/2 circle trocar point 2×HRT17, USP 2/0, blue, 90 cm | P733HRT1720-2 (AMP733HRT1720-2) | Exact reference equivalence (identical) | Same product; it is the official factory reference and the distribution SKU of Cahnos |
| Cahnos (Premisut Prime) | Polypropylene 1/2 circle trocar point 2×HRT30, USP 2/0, blue, 90 cm | AMP733HRT3020-2 | Range equivalence (not interchangeable 1:1) | Same gauge, colour, material and double needle configuration; 30 mm needle vs 17 mm. For fields or planes with greater travel |
| Cahnos (Premisut Prime) | Polypropylene 1/2 circle trocar point HRT17, USP 3/0, blue, 75 cm (single needle) | AMP732HRT1730 | Range equivalence (not interchangeable 1:1) | Same HRT17 needle geometry; finer 3/0 gauge, 75 cm thread and single needle vs double |
| Cahnos (Premisut Prime) | Polyester 1/2 circle trocar point 2×HRT17, USP 2/0, green, 90 cm | AMP853HRT1720-2 | Comparable by category (not interchangeable 1:1) | Same 2×HRT17 needle, gauge and length; multifilament polyester material coated with silicone vs monofilament polypropylene |
| B. Braun (Aesculap) | Premilene® polypropylene, 3/0, 75 cm, HRT17 needle trocar point (tapercut) ½ circle | C2090314 | Comparable by category (not interchangeable 1:1) | Matches material, ½ circle shape and 17 mm trocar point profile; different 3/0 gauge and 75 cm length. Reference confirmed based on GUDID |
| Ethicon (J&J MedTech) | PROLENE® polypropylene, 3/0, 75 cm, RB-1 ½-circle 17 mm needle | 8872H | Comparable by category (not interchangeable 1:1) | Matches material, gauge and needle size (17 mm); the RB-1 has a conical point (taper point) vs the trocar point (tapercut) of Premisut. Different penetration profile for fibrous/calcified tissue |
| Medtronic / Covidien | Surgipro™ II polypropylene with polyethylene, 3/0, 75 cm, CV-25 ½-circle needle | VP-760-X | Comparable by category (not interchangeable 1:1) | Same gauge, colour and length; CV-25 conical point needle and copolymer material (polypropylene with polyethylene), different composition from the Premisut strand |
Mandatory technical note: before substituting in a tender or operating theatre, verify one by one: exact gauge, thread length, needle shape and point (trocar vs. conical), needle size, material (pure polypropylene vs. copolymer), double needle configuration and regulatory classification (CE/MDR) of the actual product of each manufacturer. There is no equivalence table validated by the manufacturer; consult the technical department of Cahnos before use in tendering.
5. Selection tips and variants of interest
- Trocar point (tapercut): choose this configuration when the tissue presents some resistance or fibrosis (vascular, cardiovascular, fascia, adventitia); the cutting point facilitates entry and the cylindrical body minimises trauma. For very friable tissues consider the conical point (taper point) variant of the same family.
- Double needle 2×HRT17: ideal for continuous suture techniques or anastomosis with two armed ends without re-threading, especially in confined surgical fields of ophthalmology and neurosurgery. If the approach requires greater needle travel, the 2×HRT30 variant (AMP733HRT3020-2) is available.
- Gauge: USP 2/0 (metric 3) offers an excellent balance between strength and handling for medium-tension soft tissues and cardiovascular surgery. For finer planes, the same HRT17 needle is available in gauges 3/0 (AMP732HRT1730), 4/0 and 5/0 within the range.
- Prime Range: improved needle finish and superior penetration compared to the standard Premisut line; keep the reference P733HRT1720-2 and the batch number for traceability in the operating theatre and in the event of a claim.
- Verification before use: always check the integrity of the blister and the expiry date. Sterile single-use product, not re-sterilisable. For high-volume orders, purchasing centres or tenders, consult our technical-commercial team.