Description
1. Commercial Introduction
The Premisut Prime polypropylene suture is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation incorporates a double ½-circle trocar-point (Tapercut) needle of 25 mm (profile 2xHRT25), USP 3/0 gauge and a blue non-ribbed strand of 90 cm, a configuration especially indicated for cardiovascular surgery, ophthalmology and neurosurgery, as well as for approximation and ligation of soft tissues.
It is supplied sterile, ready for immediate use, in a box of 12 units with individual envelopes and batch traceability. Available at Cahnos with the factory reference P733HRT2530-2 (SKU AMP733HRT2530-2), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. As it is not absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HRT needle (½ circle, cylindrical body) with trocar point or Tapercut combines the firm penetration of a cutting point with a non-cutting body, allowing it to pass through slightly fibrous tissues, vascular adventitia or fasciae with less resistance and without tearing the suture bed. The double-needle format (2x) allows continuous suture techniques and anastomosis with two armed ends, without re-threading, optimising surgical time. The blue non-ribbed strand ensures optimal visibility over the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / line | Premisut Prime (premium range, polypropylene) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Non-grooved monofilament |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 3/0 (EP metric 2); conforms to USP and European Pharmacopoeia gauges |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Identification blue |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Trocar (Tapercut), HRT profile |
| Needle size | 25 mm (2xHRT 25) |
| Configuration | Double needle (2 × HRT) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P733HRT2530-2 |
| Reference Cahnos (SKU) | AMP733HRT2530-2 |
3.2. Premisut HRT 25 family (1/2 circle, cylindrical body, trocar point) and range variants
| Needle profile | Presentation | Reference |
| 2xHRT 25 Prime | 2 × 90 cm, USP 3/0 (product analysed) | P733HRT2530-2 / AMP733HRT2530-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 4/0 | P733HRT2540-2 / AMP733HRT2540-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 2/0 | P733HRT2520-2 / AMP733HRT2520-2 |
| 2xHRT 25 (standard) | 2 × 90 cm, USP 2/0 (ribbed) | 733HRT2520-2 / AM733HRT2520-2 |
| HRT 25 Prime (single needle) | 1 × 75 cm, USP 3/0 | P732HRT2530 / AMP732HRT2530 |
4. Equivalences and Cross-References
The reference P733HRT2530-2 corresponds to the official nomenclature of the Premisut Prime range (profile 2xHRT 25 Prime, double needle, USP 3/0 gauge, blue thread of 90 cm). There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut (Cahnos) | Polypropylene Prime 1/2 circle trocar point 2xHRT25, USP 3/0, blue, 90 cm | P733HRT2530-2 / AMP733HRT2530-2 | Exact reference equivalence (identical) | Official reference of the analysed product |
| Premisut (Cahnos) | Polypropylene 1/2 circle tapercut 2xHRT25, USP 3/0, blue, 90 cm | 733HRT2530-2 / AM733HRT2530-2 | Direct equivalent (same system) | Same needle geometry, gauge, colour and length; the premium finish of the needle varies (Prime vs. standard version) |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue monofilament polypropylene, 3-0, 90 cm, double needle CC-30 TAPERCUT 1/2 circle | W8849 (verified in Ethicon EMEA catalogue and authorised distribution; box of 12 units) | Comparable at category level (not interchangeable 1:1) | Matches material, gauge, colour, double needle, trocar point 1/2 circle and length (90 cm); CC-30 needle of 31 mm versus HRT of 25 mm. Confirm CE/MDR traceability against IFU |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue monofilament polypropylene, 3-0, 90 cm, double needle V-7 TAPERCUT 1/2 circle | 8976H (verified in authorised distribution; box of 36 units) | Comparable at category level (not interchangeable 1:1) | Same material, gauge, colour and length; V-7 TAPERCUT needle of 26 mm versus HRT of 25 mm and packaging of 36 units. Confirm exact profile in IFU |
| B. Braun (Aesculap) | Premilene® – blue monofilament polypropylene, 3/0, 90 cm, 1/2 circle needle | Series C209xxxx (e.g. profile HR26) – pending confirmation of 1:1 code | Comparable by category / pending confirmation | Same blue polypropylene base, gauge and length; verify in the technical data sheet the exact measurement and point type (trocar vs. conical) of the needle |
| Medtronic (Covidien) | Surgipro™ II – polypropylene/polyethylene copolymer, blue, 3/0 | VP558X (confirm needle profile in tender) | Comparable by category, not interchangeable 1:1 | Copolymer material (not pure polypropylene) and conical point according to distribution; verify number of needles, measurement and presentation against IFU |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene® or Surgipro™ II are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Trocar point (Tapercut): choose this configuration when the tissue presents some resistance or fibrosis (vascular, cardiovascular, fascia); the cutting point facilitates entry and the cylindrical body minimises trauma. For very friable tissues, consider the conical point variant (HR, Taperpoint) of the same Premisut Prime family.
Gauge: USP 3/0 (metric EP 2) is very versatile for vascular, cardiovascular and general soft tissue surgery. If greater strength is required, the same 2xHRT25 needle is available in USP 2/0 (P733HRT2520-2); for finer tissues, 4/0 gauges of the range (P733HRT2540-2).
Needle length: the 25 mm HRT offers a good balance between control and penetration in deep fields. For deeper approaches, consider the 30 mm HRT (P733HRT3030-2, USP 3/0) and for more restricted fields the 17 mm HRT (P733HRT1730-2, USP 3/0).
Presentation: the double-needle version 2 × 90 cm optimises thread utilisation and facilitates continuous sutures and anastomosis; if your protocol prefers a single needle, P732HRT2530 (1 × 75 cm, USP 3/0) is available.
Sterility verification: sterile product by ethylene oxide, single-use; check the integrity of the blister and the expiry date before each use and keep the reference P733HRT2530-2 and the batch number for traceability in the operating theatre and in case of claim.





Reviews