Description
1. Commercial Introduction
The polypropylene suture Premisut is the reference choice for surgical departments, procurement centres and tenders seeking a non-absorbable suture with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation includes double ½ circle trocar point (Tapercut) needle of 25 mm (profile 2xHRT 25), USP size 0 and a blue thread of 90 cm, a configuration particularly valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
It is supplied sterile, ready for immediate use, in a box of 12 units with individual sachets and batch traceability. Available at Cahnos with the factory reference 733HRT2510-2 (SKU AM733HRT2510-2), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence nor the formation of sinuses in wounds at risk of contamination and minimises suture extrusion. As it is non-absorbable, it is not degraded by tissue enzymes: it becomes gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HRT needle (½ circle, cylindrical body) with trocar or Tapercut point combines the firm penetration of a cutting point with a non-cutting body, allowing it to pass through slightly fibrous tissues, vascular adventitia or fascias with less resistance and without tearing the suture bed. The double needle format (2x) allows continuous suture techniques and anastomosis with two armed ends, without re-threading, optimising surgical time. The highly visible blue thread facilitates identification of the suture and the knot on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / line | Premisut (polypropylene, standard range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament (fluted surface for high visibility) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 0 (EP metric 3.5; diameter 0.35 – 0.399 mm); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Identification blue |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Trocar (Tapercut), HRT profile |
| Needle size | 25 mm (2xHRT 25) |
| Configuration | Double needle (2 × HRT) |
| Manufacturing quality | Normal (standard) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | 733HRT2510-2 |
| Reference Cahnos (SKU) | AM733HRT2510-2 |
3.2. Premisut HRT 25 family (1/2 circle, cylindrical body, trocar point) and range variants
| Needle profile | Presentation | Reference |
|---|---|---|
| 2xHRT 25 (standard) | 2 × 90 cm, USP 0 (analysed product) | 733HRT2510-2 / AM733HRT2510-2 |
| 2xHRT 25 (standard) | 2 × 90 cm, USP 2/0 | 733HRT2520-2 / AM733HRT2520-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 0 (non-grooved) | P733HRT2510-2 / AMP733HRT2510-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 2/0 | P733HRT2520-2 / AMP733HRT2520-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 3/0 | P733HRT2530-2 / AMP733HRT2530-2 |
| 2xHRT 25 Prime | 2 × 90 cm, USP 4/0 | P733HRT2540-2 / AMP733HRT2540-2 |
| 2xHRT 30 (standard) | 2 × 90 cm, USP 2/0 | 733HRT3020-2 / AM733HRT3020-2 |
| 2xHRT 30 (standard) | 2 × 90 cm, USP 3/0 | 733HRT3030-2 / AM733HRT3030-2 |
4. Equivalences and Cross-References
The reference 733HRT2510-2 corresponds to the official nomenclature of the Premisut range (profile 2xHRT 25, double needle, USP size 0, blue thread 90 cm). There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut (Cahnos) | Polypropylene 1/2 circle trocar point 2xHRT25, USP 0, blue, 90 cm | 733HRT2510-2 / AM733HRT2510-2 | Exact reference equivalence (identical) | Official reference of the analysed product |
| Premisut Prime (Cahnos) | Polypropylene 1/2 circle trocar point 2xHRT25, USP 0, blue, 90 cm | P733HRT2510-2 / AMP733HRT2510-2 | Direct equivalent (same system) | Same needle geometry, size, colour and length; the premium needle finish varies (Prime version, non-grooved thread) |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, USP 0, 90 cm, double V-7 TAPERCUT needle 1/2 circle 26 mm | 8978H (verified in authorised distribution and reference catalogues; box of 36 units) | Comparable at category level (not interchangeable 1:1) | Matches material, size, colour, double needle, trocar point 1/2 circle and length (90 cm); V-7 needle of 26 mm versus HRT of 25 mm and packaging of 36 units. Confirm IFU and CE/MDR traceability |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, USP 0, 90 cm, 1/2 circle TAPERCUT needle | NW894 (verified in authorised distribution; box of 12 units) | Comparable at category level (not interchangeable 1:1) | Matches material, size, colour and length; TAPERCUT needle of heavy profile and armed (single vs. double) to be confirmed in IFU versus HRT of 25 mm |
| Medtronic (Covidien) | Surgipro™ II – polypropylene monofilament with polyethylene, blue, USP 0, 90 cm (36″), KV-7 tapercutting needle 1/2 circle 26 mm | VP978 (verified in authorised distribution; box of 36 units) | Comparable by category, not interchangeable 1:1 | Copolymer material (not pure polypropylene); KV-7 needle of 26 mm versus HRT of 25 mm and packaging of 36 units. Verify IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 0, 90 cm, 1/2 circle needle | Series C209xxxx – pending confirmation of 1:1 code for trocar point USP 0 | Comparable by category / pending confirmation | Premilene range confirmed with HRT trocar point (e.g. C2090340, 4/0 HRT26); for USP 0 of 90 cm verify in the official technical data sheet the needle profile (conical HR vs. trocar HRT) and the measurement in mm |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Surgipro™ II or Premilene® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Trocar point (Tapercut): choose this configuration when the tissue presents some resistance or fibrosis (vascular, cardiovascular, adventitial); the cutting point facilitates entry and the cylindrical body minimises trauma. For very friable tissues, consider the conical point variant (HR, Taperpoint) of the same Premisut family, e.g. reference AM733HR2510-2 (USP 0, 90 cm).
- USP size 0: offers high strength and is widely used in cardiovascular, vascular and soft tissue under tension. If greater strength is required, the same 2xHRT25 needle is available in larger sizes; for finer tissues, consider the 2/0 (AM733HRT2520-2), 3/0 (AMP733HRT2530-2) and 4/0 (AMP733HRT2540-2) versions of the range.
- Needle length: the 25 mm HRT offers a good balance between control and penetration in deep fields. For deeper approaches, consider the 30 mm HRT in 2/0 and 3/0 (733HRT3020-2 / 733HRT3030-2).
- Prime range: the Premisut Prime line maintains the same needle geometry with non-grooved thread and improved needle finish; use reference AMP733HRT2510-2 when the protocol requires a premium finish.
- Prior verification: always confirm the full reference (needle 2xHRT 25, USP gauge 0 and length 90 cm) on the packaging; check the integrity of the blister and the expiry date before each use and keep the batch number for traceability in the operating theatre. Single-use product, not re-sterilisable.