Description
1. Commercial Introduction
The polypropylene suture Premisut Prime is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation incorporates a double ½-circle trocar-point (Tapercut) needle of 17 mm (2xHRT 17 Prime profile), USP 5/0 gauge and a 90 cm blue non-grooved strand: a configuration especially indicated for cardiovascular surgery, ophthalmology and neurosurgery, as well as for the approximation and ligation of soft tissues.
It is supplied sterile, ready for immediate use, in a box of 12 units with individual sachets and batch traceability. Available at Cahnos with the factory reference P733HRT1750-2 (SKU AMP733HRT1750-2), with the characters unchanged.
2. Technical Explanation
Polypropylene is a linear synthetic polyolefin that is presented as an uncoated monofilament: as it has no interstices and no wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. As it is non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HRT needle (½ circle, cylindrical body) with trocar or Tapercut point combines the firm penetration of a cutting point with a non-cutting body: it passes through slightly fibrous tissues, vascular adventitia or fasciae with less resistance and without tearing the suture bed. The double-needle format (2x) allows continuous suture techniques and anastomoses with two armed ends, without re-threading, optimising surgical time. The blue non-grooved strand guarantees optimal visibility over the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / line | Premisut Prime (premium range, polypropylene) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Non-grooved monofilament |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 5/0 (metric EP 1.0); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 90 cm per unit (double-armed) |
| Thread colour | Identification blue |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Trocar (Tapercut), HRT profile |
| Needle size | 17 mm (2xHRT 17) |
| Configuration | Double needle (2 × HRT 17) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P733HRT1750-2 |
| Reference Cahnos (SKU) | AMP733HRT1750-2 |
Family Premisut Prime 2xHRT 17 (1/2 circle, cylindrical body, trocar point, double needle):
| Needle profile | USP size | Presentation | Reference |
|---|---|---|---|
| 2xHRT 17 Prime | 5/0 | 2 × 90 cm | P733HRT1750-2 / AMP733HRT1750-2 (this product) |
| 2xHRT 17 Prime | 4/0 | 2 × 90 cm | P733HRT1740-2 / AMP733HRT1740-2 |
| 2xHRT 17 Prime | 3/0 | 2 × 90 cm | P733HRT1730-2 / AMP733HRT1730-2 |
| 2xHRT 17 Prime | 2/0 | 2 × 90 cm | P733HRT1720-2 / AMP733HRT1720-2 |
| HRT 17 Prime (single needle) | 5/0 | 1 × 75 cm | P732HRT1750 / AMP732HRT1750 |
4. Equivalences and Cross-References
The reference P733HRT1750-2 corresponds to the official nomenclature of the Premisut Prime range (2xHRT 17 Prime profile, double needle, USP 5/0 gauge, 90 cm blue thread). Cahnos markets the product keeping the factory reference with characters unchanged. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1 without prior technical validation against the technical data sheet or the instructions for use (IFU) of each manufacturer.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut Prime (Cahnos) | Polypropylene 1/2 circle trocar point 2xHRT17, USP 5/0, blue, 90 cm | P733HRT1750-2 / AMP733HRT1750-2 | Exact reference equivalence (identical) | Official reference of the product analysed in this data sheet. |
| B. Braun (Aesculap) | Premilene® – blue monofilament polypropylene, 5/0, 90 cm, double needle 2xHRT17 trocar point (Tapercut) 1/2 circle | C2090925 (verified in device registry and GUDID database 04046963637125: PREMILENE 5/0 (1) 90CM 2XHRT17 (M) RCP) | Functional equivalence by specifications (no official cross-reference table) | Material, gauge, colour, length (90 cm), double needle and 17 mm trocar-point geometry in 1/2 circle match; commercial presentation (box of 36 units), brand and needle finish differ. Confirm IFU. |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, 5-0, 90 cm (36″), double needle V-5 TAPERCUT of 17 mm, ½ circle | 8934H (verified in official Ethicon Product Center catalogue: “5-0 PROLENE BLUE 1X36″ V-5 DOUBLE ARMED”, box of 36 units) | Functional equivalence by specifications (no official cross-reference table) | Material, gauge, colour, length (90 cm) and needle geometry (17 mm, ½ circle, Tapercut trocar point) match; commercial presentation (box of 36 units) and needle finish differ. Confirm IFU. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene copolymer with polyethylene, blue, 5-0, 90 cm, CV-23 needle conical point | VP-660-X (confirmed in authorised distribution) | Comparable by category, not interchangeable 1:1 | Gauge, colour and length match; but copolymer material (not pure polypropylene) and conical point (Taper Point) versus trocar point. Verify IFU. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with Premilene®, PROLENE® or Surgipro™ II are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Trocar point (Tapercut): choose this configuration when the tissue presents some resistance or fibrosis (vascular, cardiovascular, fascia, adventitia); the cutting point facilitates entry and the cylindrical body minimises trauma. For very friable tissues, consider the conical point (Taper Point) variant of the same Premisut Prime family.
- USP 5/0 gauge: offers the balance between strength and manageability for fine or moderately tensioned tissues, being common in peripheral cardiovascular surgery, ophthalmology and neurosurgery. With the same 2xHRT17 needle, variants are available in USP 4/0 (AMP733HRT1740-2), 3/0 (AMP733HRT1730-2) and 2/0 (AMP733HRT1720-2) for greater mechanical support.
- Needle length: the 17 mm HRT is ideal for surgical fields of medium depth and delicate tissues. For deeper approaches, consider the 25 mm HRT in double needle (e.g. AMP733HRT2540-2 in USP 4/0).
- Double needle (2 × 90 cm): optimises thread utilisation and facilitates continuous sutures and anastomoses with two armed ends, without re-threading; if your protocol prefers a single needle, P732HRT1750 is available in 1 × 75 cm.
- Prior verification: product sterile by ethylene oxide and single-use; confirm the full reference on the packaging, the integrity of the blister, the expiry date and keep the batch number for traceability in the operating theatre and in the event of a claim.





Reviews
There are no reviews yet.