We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Non-absorbable polypropylene suture Premisut Prime, double ½-circle needle with trocar point (Tapercut) 2×HRT17 of 17 mm, USP 4/0, blue, 90 cm – Box of 12 units (Ref. P733HRT1740-2 · SKU AMP733HRT1740-2)

83,01 €

Non-absorbable monofilament polypropylene surgical suture Premisut Prime, with double ½-circle needle, cylindrical body and trocar point (Tapercut) of 17 mm (profile 2xHRT17 Prime). USP gauge 4/0 (metric EP 1.5), blue non-grooved thread of 90 cm, uncoated and with gradual encapsulation that maintains wound support for more than three months. Sterilised by ethylene oxide and single-use, presented in a box of 12 individual sachets with batch traceability. Indicated for approximation and ligation of soft tissues, cardiovascular surgery, ophthalmology and neurosurgery. Manufacturer reference P733HRT1740-2 · SKU Cahnos AMP733HRT1740-2.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP733HRT1740-2

Description

1. Commercial Introduction

The polypropylene suture Premisut Prime with double ½-circle needle with trocar point (Tapercut) of 17 mm is the reference solution for surgical services, purchasing centres and tenders seeking a high-performance non-absorbable thread with predictable behaviour and minimal tissue reaction. This presentation in USP 4/0 gauge (metric EP 1.5), blue colour and 90 cm strand armed at both ends, allows unifying criteria in procedures for approximation and ligation of soft tissues, as well as in demanding specialties such as cardiovascular surgery, ophthalmology and neurosurgery.

It is supplied sterile, ready for immediate use in the operating theatre, in a box of 12 units with individual envelopes and full batch traceability. Available at Cahnos under the factory reference P733HRT1740-2 (SKU AMP733HRT1740-2), maintained without altering characters.

2. Technical Explanation

The thread is manufactured from isotactic polypropylene, a linear synthetic polyolefin with high chemical inertia that is presented as an uncoated, non-grooved monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, reduces tissue drag, avoids the saw effect on delicate tissues and minimises bacterial adherence. As it is non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.

The HRT ½-circle needle with cylindrical body and trocar point (Tapercut) combines the firm penetration of a three-edged cutting point with the minimal aggression of a round-point needle: it passes through slightly fibrous tissues, vascular adventitia or calcified walls with less resistance and without tearing the suture bed. The double-needle configuration (2×HRT17) allows continuous sutures or anchors with two armed ends without re-threading, optimising surgical time in reduced fields. The blue colour guarantees optimal visibility over the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

Parameter Specification
Brand / line Premisut Prime (premium range, improved finish needle)
Thread material Polypropylene monofilament, uncoated, dyed blue (phthalocyanine blue)
Thread structure Non-grooved monofilament (without grooves)
Absorption Non-absorbable; gradual encapsulation; wound support for over 3 months
USP gauge / size USP 4/0 (metric EP 1.5)
Approximate thread diameter 0.150 – 0.199 mm (indicative per USP Pharmacopoeia, non-absorbable suture)
Thread length 90 cm (1 thread per unit, armed at both ends)
Thread colour Blue (high visibility in the surgical field)
Needle shape ½ circle (1/2 circle)
Needle body / tip Cylindrical body, trocar point (Tapercut), non-grooved
Needle configuration and size Double needle 2×HRT 17, 17 mm (stainless steel, Prime finish)
Number of needles 2 (double needle)
Sterilisation Ethylene oxide (EO); sterile, single-use, non-resterilisable
Commercial presentation Box of 12 units (individual sterile sachets)
Indications Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery
Storage Below 30 °C, away from moisture and direct sunlight
Factory reference P733HRT1740-2
SKU Cahnos AMP733HRT1740-2

Gauge equivalence (indicative according to USP/EP Pharmacopoeia):

USP size Metric size Approximate diameter
4/0 1.5 (EP) 0.150 – 0.199 mm (non-absorbable suture)

Family Premisut HRT 17 Prime (½ circle, cylindrical body, trocar point) and range variants:

Needle profile USP size Presentation Reference Cahnos
2xHRT 17 Prime 4/0 2 × 90 cm (product analysed) AMP733HRT1740-2
2xHRT 17 Prime 3/0 2 × 90 cm AMP733HRT1730-2
2xHRT 17 Prime 2/0 2 × 90 cm AMP733HRT1720-2
2xHRT 17 Prime 5/0 2 × 90 cm AMP733HRT1750-2
HRT 17 Prime (single needle) 3/0 1 × 75 cm AMP732HRT1730

4. Equivalences and Cross-References

The blue non-absorbable polypropylene monofilament is one of the most standardised permanent suture families on the market (commercially known as type «Prolene»). There is no official equivalence table validated by the manufacturer that cross-references this specific reference against other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution. Always consult the technical department of Cahnos to validate any equivalence.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Cahnos (Premisut Prime) Polypropylene 1/2 circle trocar point 2×HRT17, USP 4/0, blue, 90 cm P733HRT1740-2 (AMP733HRT1740-2) Exact reference equivalence (identical) Same product; official factory reference and Cahnos distribution SKU
Cahnos (Premisut Prime) Polypropylene 1/2 circle trocar point 2×HRT17, USP 3/0, blue, 90 cm AMP733HRT1730-2 Range equivalence (not interchangeable 1:1) Same needle 2×HRT17, colour and length; gauge varies (USP 3/0, finer)
Cahnos (Premisut Prime) Polypropylene 1/2 circle trocar point 2×HRT17, USP 2/0, blue, 90 cm AMP733HRT1720-2 Range equivalence (not interchangeable 1:1) Same needle 2×HRT17, colour and length; gauge varies (USP 2/0, larger diameter)
Cahnos (Premisut Prime) Polypropylene 1/2 circle trocar point 2×HRT17, USP 5/0, blue, 90 cm AMP733HRT1750-2 Range equivalence (not interchangeable 1:1) Same needle 2×HRT17, colour and length; USP 5/0 gauge for more delicate planes
Cahnos (Premisut Prime) Polypropylene 1/2 circle trocar point HRT17, USP 3/0, blue, 75 cm (single needle) AMP732HRT1730 Range equivalence (not interchangeable 1:1) Same needle geometry and point; 75 cm thread and single needle versus double 90 cm
Ethicon (J&J MedTech) PROLENE® blue polypropylene monofilament, USP 4/0 (1.5), 90 cm, double or single V-5 ½-circle trocar point (Tapercut) needle of 17 mm W8935 (EMEA, box of 12) / 8935H (box of 36) Functional equivalence by specifications (no official cross-reference table) Matches material, gauge, colour, length (90 cm), ½-circle arc and trocar point (Tapercut) of 17 mm. Codes verified in Ethicon catalogue and authorised distribution; confirm presentation and batch against IFU
B. Braun (Aesculap) Premilene® blue polypropylene monofilament, USP 4/0 (1.5), 90 cm, double needle 2×HR17 of 17 mm (½ circle, round body) C2090902 Comparable by category (not interchangeable 1:1) Matches material, gauge, colour, double needle, length and needle size (17 mm); the HR has a conical point (taper point) versus the trocar point (tapercut) of Premisut. Reference verified in GUDID / B. Braun catalogues
Medtronic / Covidien Surgipro™ II polypropylene with polyethylene, USP 4/0, 90 cm, conical point ½-circle needle VP-521-X Comparable by category (not interchangeable 1:1) Matches gauge, colour and length; copolymer material (polypropylene with polyethylene) and conical point, composition and penetration profile different from the Premisut strand

Mandatory technical note: before substituting in a tender or operating theatre, verify one by one: exact gauge, thread length, needle shape and point (trocar vs. conical), needle size, material (pure polypropylene vs. copolymer), double-needle configuration and regulatory classification (CE/MDR) of each manufacturer’s actual product. There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department of Cahnos before using this information in tendering or direct substitution.

5. Selection tips and variants of interest

Trocar point (Tapercut): choose this configuration when the tissue presents some resistance or fibrosis (vascular, cardiovascular, fascia, adventitia); the cutting point facilitates entry and the cylindrical body minimises trauma. For very friable tissues, consider the conical point (taper point) variant of the same Premisut family.

Double needle 2×HRT17: ideal for continuous suture techniques or anastomosis with two armed ends without re-threading, especially in reduced surgical fields in ophthalmology and neurosurgery. If the approach requires a longer needle path, the 2×HRT25 variant is available (AMP733HRT2540-2, same USP 4/0 gauge).

Gauge: USP 4/0 (metric 1.5) offers an excellent balance between strength and handling for fine tissues or moderate tension. With the same HRT17 needle, the USP 5/0 (AMP733HRT1750-2), USP 3/0 (AMP733HRT1730-2) and USP 2/0 (AMP733HRT1720-2) variants are available.

Presentation: the double-needle version 2 × 90 cm optimises thread utilisation and facilitates continuous sutures; if your protocol prefers a single needle, AMP732HRT1730 (1 × 75 cm, USP 3/0) is available.

Prime range: improved needle finish and superior penetration compared to the standard Premisut line; keep the reference P733HRT1740-2 and the batch number for traceability in the operating theatre and in case of complaint. Verification before use: always check the integrity of the blister and the expiry date. Sterile single-use product, not re-sterilisable. For high-volume orders, purchasing centres or tenders, consult our technical-commercial team.

Additional information

Material

Polypropylene monofilament, uncoated, dyed blue (phthalocyanine blue)

Thread structure

Non-grooved monofilament (without grooves)

Absorption

Non-absorbable; gradual encapsulation; wound support for over 3 months

USP size

4/0 (metric EP 1.5)

Metric gauge (EP)

1.5 (EP)

Thread colour

Blue (high visibility)

Needle shape

½ circle (1/2 circle)

Needle type

Cylindrical body with trocar point (Tapercut)

Needle size

2xHRT17, 17 mm (Prime finish)

Configuration

Double needle (2 × HRT)

Manufacturing quality

Prime (premium range)

Sterilisation

Ethylene oxide (EO); sterile, single-use, non-resterilisable

Presentation

Box of 12 units (individual sterile sachets)

Indications

Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery

Manufacturer reference

P733HRT1740-2

Brand

Premisut Prime (premium range)

Approximate suture diameter

0.150 – 0.199 mm (non-absorbable suture, USP)

Number of threads

1 strand per unit, armed at both ends

Number of needles

2 (double needle)

Medida de aguja

2xHRT 17 prime

Usp

4/0

Color

Blue

Medida de hilo

2 × 90 cm, 90 cm

Tipo de aguja

Cylindrical trocar tip

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Non-absorbable polypropylene suture Premisut Prime, double ½-circle needle with trocar point (Tapercut) 2×HRT17 of 17 mm, USP 4/0, blue, 90 cm – Box of 12 units (Ref. P733HRT1740-2 · SKU AMP733HRT1740-2)”