Description
Polypropylene Suture PREMISUT – Precision and reliability in every stitch
The non-absorbable polypropylene suture PREMISUT is the trusted solution for the surgical professional who demands a predictable, safe and high-performance closure. In USP size 2/0, with blue thread of 75 cm and a ½ circle needle with cylindrical body and trocar point (tapercut) of 36 mm, this reference is designed to offer clean penetration even in firm or fibrous tissues, maintaining the integrity of the approximation for months.
Technical product explanation
Polypropylene is a synthetic linear polyolefin that is processed into isotactic crystalline monofilament. This configuration provides an excellent combination of properties: minimal tissue adherence, low inflammatory response, high ductility (the thread can stretch up to 30 % before breaking, which accommodates postoperative inflammation without strangulating the tissue) and very prolonged tensile strength retention, with gradual encapsulation by fibrous tissue. The HRT 36 needle combines a cylindrical body with a trocar point (tapercut), which penetrates dense tissues without tearing, and its ½ circle geometry facilitates handling in deep planes and stitch control in minimally invasive and open surgery.
Technical specifications
| Parameter | Value |
|---|---|
| Material | Uncoated polypropylene monofilament |
| Absorption | Non-absorbable (permanent, gradual encapsulation) |
| Gauge | USP 2/0 (metric 3.0 approx.) |
| Thread colour | Ribbed blue |
| Thread length | 75 cm |
| Needle shape | ½ circle |
| Needle type | Cylindrical body, trocar point (tapercut) HRT |
| Needle size | 36 mm |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 12 sterile single-use units |
| Manufacturer reference | 732HRT3620 |
Equivalences and cross-references
Exact reference equivalence (1:1): no external reference has been found that matches in all fields (same manufacturer of the HRT 36 tapercut needle, USP size 2/0, blue thread of 75 cm) in the official catalogues consulted. The Ethicon 8444H reference (Prolene® USP 0, V-34 tapercut 36 mm, 75 cm, blue) shares the same needle pattern but in USP size 0, therefore it is not interchangeable with reference AM732HRT3620.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J) | Prolene® Polypropylene, V-7 tapercut ½ circle needle | 8977H | Comparable by category (not interchangeable 1:1) | Same USP size 2/0 and tapercut point, but V-7 needle of 26 mm and thread of 90 cm. Verified in official Ethicon catalogue. |
| Ethicon (J&J) | Prolene® Polypropylene, CT-1 taper point ½ circle needle | 8423H | Comparable by category (not interchangeable 1:1) | Same USP size 2/0, needle of 36 mm and thread of 75 cm, but conical point (taper point), not trocar. Confirm surgical technique before substituting. |
| Ethicon (J&J) | Prolene® Polypropylene, MH taper point ½ circle needle | 8843H | Comparable by category (not interchangeable 1:1) | Same USP size 2/0, MH needle of 36 mm conical point, thread of 90 cm. Neither the point nor the thread length matches. |
| Medtronic / Covidien | Surgipro™ II Polypropylene, KV-7 tapercutting needle | VP977 | Comparable by category (not interchangeable 1:1) | Same USP size 2/0 and tapercut point, but KV-7 needle of shorter length and thread of 90 cm. Verified in authorised distributors. |
| DemeTECH | DemeLENE® Polypropylene, DSH 26 mm round body needle | PM292026B0P | Comparable by category (not interchangeable 1:1) | Same USP size 2/0, blue thread of 75 cm, but DSH needle of 26 mm round body (not tapercut). Confirm technique before substituting. |
| DemeTECH | DemeLENE® Polypropylene, DCT-2 26 mm round body needle | PM292026B1P | Comparable by category (not interchangeable 1:1) | Same USP size 2/0, blue thread of 75 cm, but DCT-2 needle of 26 mm round body. Verify point geometry. |
| B.Braun | Dafilon® Polypropylene, DS24 needle | C0935360 | Comparable by category (not interchangeable 1:1) | Same USP size 2/0 and blue thread of 75 cm. Confirm geometry and length of the DS24 needle in the official B.Braun catalogue before use. |
Important: there is no equivalence table validated by the manufacturer for this reference; consult our technical department before using these cross-references in tenders or closed surgical protocols.
Selection tips and variants of interest
Before substituting this suture for another reference, always verify: point geometry (trocar/tapercut vs. conical), USP size, thread length and needle measurement. For the same HRT 36 needle configuration in USP size 0, you have reference AM732HRT3610. If you require greater hardness and precision sharpening, the PREMISUT PRIME line offers this same USP 2/0 configuration in reference AMP732HRT3620. You may also consider 25 mm trocar needles (AM732HRT2520) or conical point of 30 and 35 mm (AM732HR3020 and AM732HR3520). For procedures requiring absorbable suture with the same needle, consult reference AM222HRT3620 (PGAR RÁPIDO).





Reviews
There are no reviews yet.