Description
1. Commercial Introduction
The polypropylene suture Premisut Prime is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle capable of penetrating tissues of moderate consistency with total control. This presentation in USP 5/0 gauge, with a ⅜ circle needle, cylindrical body and trocar point (tapercut) of 17 mm (DRT 17 Prime profile) and blue thread of 75 cm, is indicated for approximation of soft tissues, ligatures and high-demand procedures in general, cardiovascular, ophthalmology and neurosurgery.
It is supplied sterile and ready for individual use in a box of 12 units with batch traceability, facilitating hospital stock management and presentation to public tenders. Available at Cahnos with factory reference P732DRT1750 (SKU AMP732DRT1750), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence nor the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, helping the wound for more than three months.
The DRT 17 Prime needle (⅜ circle, cylindrical body with trocar point type Tapercut of 17 mm) combines the precise penetration of a sharp point with a non-cutting body that separates fibres without cutting them: it passes through dense or slightly fibrous tissues with less resistance and without cutting effect on adjacent tissue, reducing trauma and bleeding. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Non-grooved monofilament |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 5/0 (metric EP 1.0); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm per unit |
| Thread colour | Identification blue |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle body | Cylindrical |
| Tip type | Trocar (Tapercut), DRT profile |
| Needle size | 17 mm (DRT 17 Prime) |
| Configuration | Single needle (1 × DRT) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P732DRT1750 |
| Reference Cahnos (SKU) | AMP732DRT1750 |
DRT 17 family (⅜ circle, cylindrical body, trocar point) within the Premisut Prime range:
| Needle profile | USP size | Presentation | Reference Cahnos |
| DRT 17 Prime | 3/0 | 1 × 75 cm | AMP732DRT1730 |
| DRT 17 Prime | 4/0 | 1 × 75 cm | AMP732DRT1740 |
| DRT 17 Prime | 5/0 | 1 × 75 cm | AMP732DRT1750 (analysed product) |
| 2xDRT 17 Prime | 4/0 | 2 × 75 cm | AMP732DRT1740-2 |
| 2xDRT 17 Prime | 5/0 | 2 × 75 cm | AMP732DRT1750-2 |
| 2xDRT 17 Prime | 4/0 | 2 × 90 cm | AMP733DRT1740-2 |
| HRT 17 Prime (½ circle, trocar point) | 5/0 | 1 × 75 cm | AMP732HRT1750 |
4. Equivalences and Cross-References
The reference P732DRT1750 corresponds to the official nomenclature of the Premisut Prime range (DRT 17 Prime profile, single needle, USP 5/0 gauge, 75 cm thread). Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range (Cahnos) | Polypropylene DRT 17 Prime, USP 5/0, blue, 75 cm | P732DRT1750 / AMP732DRT1750 | Direct product reference | Product analysed in this data sheet |
| Premisut Prime range (Cahnos) | Polypropylene 2xDRT 17 Prime, USP 5/0, blue, 2 × 75 cm | AMP732DRT1750-2 | Configuration equivalent within the same system | Same DRT 17 needle and USP 5/0 gauge; double needle format instead of single needle |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue monofilament polypropylene, 5-0, 75 cm, V-4 TAPERCUT 17 mm needle, ⅜ circle | F2829 (verified in catalogues of authorised distributors) | Functional equivalence by specifications (no official cross-reference table) | Matches in material, gauge, colour, length (75 cm) and needle geometry (17 mm, ⅜, trocar point); reference F2829 is marketed in double needle version and box of 36 units versus single needle and box of 12 units |
| B. Braun (Aesculap) | Premilene® – blue monofilament polypropylene, USP 5/0 | C2090319 (verified in RevMed / GUDID device database) | Comparable by category / pending 1:1 confirmation | Same blue polypropylene base and EP 1 gauge; confirm in the technical data sheet the exact measurement, arc and point type of the needle (17 vs 18 mm) and the number of needles |
| Medtronic (Covidien) | Surgipro™ II – polypropylene monofilament with polyethylene, blue, 5/0 | VP580X (confirm needle profile in tender) | Comparable by category, not interchangeable 1:1 | Copolymer with polyethylene (different material); strand of 90 cm versus 75 cm; verify exact measurement, number of needles and presentation against IFU |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | 2x DR-17 blue profile, USP 5/0, 75 cm – consult order code according to catalogue | Comparable by category / pending confirmation | Trocar needle profile 17 mm very close; confirm needle arc, number of needles and official code with the distributor |
| Vitrex / Chirana | Chiralen – blue monofilament polypropylene | 4022PP 5310 (Chiralen 5/0, DRT13, 75 cm, 3/8 trocar needle of 13 mm) | Comparable by category / not interchangeable 1:1 | Same material, gauge and length (75 cm) with 3/8 trocar point; 13 mm needle versus 17 mm and box of 24 units; verify needle format |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®, Surgipro™ II, SERAPREN® or Chiralen are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Tissue to suture: the DRT needle with trocar point (Tapercut) is suitable for tissues of moderate or slightly fibrous consistency that require firm penetration with minimal aggression (skin, mucosa, subcutaneous tissue, vascular planes and ophthalmology). For very friable tissues consider conical point profiles (DR) from the same Premisut Prime range.
Needle size: the 17 mm DRT is a medium-length needle, ideal for reduced surgical fields; if you need a shorter needle, the 13 mm DRT family is available in the same gauge (AMP732DRT1350 / AMP732DRT1350-2).
Gauge: USP 5/0 (metric 1.0) offers the balance between strength and manageability for fine tissues or moderate tension; for greater support consider USP 4/0 (AMP732DRT1740) or USP 3/0 (AMP732DRT1730) with the same DRT 17 needle.
Configuration: if your protocol prefers double-needle thread (continuous suture or anastomosis techniques), the same family is available in 2xDRT 17 (AMP732DRT1750-2, 2 × 75 cm) and in 2 × 90 cm (AMP733DRT1740-2).
Alternative curvature: for a ½ circle arc with a 17 mm trocar point in 5/0, see the HRT variant of the same range (AMP732HRT1750); for conical point (Taperpoint), the DR 17 variant (AMP732DR1750). The choice of arc depends on the approach and the depth of the surgical field.
Sterility verification: product sterile by ethylene oxide, single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732DRT1750 and the batch number for traceability in the operating theatre and in case of claim.





Reviews