Description
1. Commercial Introduction
The polypropylene suture PREMISUT is a consolidated reference in surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that penetrates tissue with total control. This presentation in gauge USP 2, with a ½ circle conical point Taperpoint needle of 40 mm (HR 40 profile) and a 75 cm blue thread, is especially indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
It is supplied sterile, ready for single use, in a box of 12 units with batch traceability, facilitating hospital stock management and presentation to public tenders. Available at Cahnos under the factory reference 732HR4002 (SKU AM732HR4002).
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (molecular formula (C3H6)n) that is presented as uncoated monofilament, dyed blue with phthalocyanine. Lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is neither absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, helping the wound for more than three months.
The HR 40 needle (½ circle, cylindrical body and 40 mm conical Taperpoint point) separates and displaces tissue fibres without cutting them, making it ideal for soft, vascular and poorly distensible planes that require controlled penetration and minimal injury. The fluted finish of the needle body facilitates smooth delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / Line | PREMISUT – standard quality (standard manufacturing) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue (phthalocyanine); ≥ 99.5 % polypropylene / ≤ 0.5 % phthalocyanine |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 2 (EP metric 5; approximate diameter 0.50 – 0.599 mm); in accordance with USP and European Pharmacopoeia gauges |
| Thread length | 1 thread of 75 cm per unit |
| Thread colour | Identifying blue, high visibility |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Taperpoint conical point (cylindrical body), grooved (HR profile) |
| Needle size | 40 mm (HR 40 profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | 732HR4002 |
| Reference Cahnos (SKU) | AM732HR4002 |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
Gauge equivalence (USP/EP standard): USP gauge 2 corresponds to metric size 5, with an approximate thread diameter of 0.50 – 0.599 mm.
4. Equivalences and Cross-References
Reference 732HR4002 corresponds to the official nomenclature of the PREMISUT range (HR 40 profile, 1 thread of 75 cm, USP gauge 2, blue colour), verified against the manufacturer’s technical data sheet. Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tendering or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| PREMISUT (Cahnos) | Polypropylene HR 40, USP 2, blue, 1 × 75 cm (standard) | 732HR4002 / AM732HR4002 | Direct product reference | Product analysed in this data sheet |
| PREMISUT Prime (Cahnos) | Polypropylene HR 40 Prime, USP 2, blue, 1 × 75 cm | P732HR4002 / AMP732HR4002 | Direct equivalent within the same family | Same measurements and material; Prime quality needle (PREMILLOY steel, improved penetration) versus standard |
| PREMISUT Prime (Cahnos) | Polypropylene HR 40 Prime, USP 2, blue, 2 × 75 cm | P732HR4002.2 / AMP732HR4002.2 | Configuration equivalent within the same system | Same HR 40 needle and USP gauge 2; the presentation changes to double thread |
| PREMISUT (Cahnos) | Polypropylene HR 40, USP 1 and USP 0, blue, 1 × 75 cm | 732HR4001 / AM732HR4001 · 732HR4010 / AM732HR4010 | Comparable within the same system | Same HR 40 needle and length; the USP gauge changes (1 and 0) |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament (USP 2, ½ circle needle, conical point 40 mm) | Pending confirmation of 1:1 code (NW846 and 8690H verified in USP 0 calibre) | Comparable by category, not interchangeable 1:1 | Same blue polypropylene base; confirm in IFU the exact combination of 40 mm conical needle + USP 2 + 75 cm |
| B. Braun | Premilene® / Optilene® – blue polypropylene monofilament | Series C2090 – pending confirmation for HR 40, USP 2 | Pending confirmation | Verify needle geometry and size, calibre and presentation in official catalogue |
| Medtronic (Covidien) | Surgipro™ II – polypropylene with polyethylene, blue monofilament | CP-424 verified in USP 0; pending for USP 2 | Comparable by category / pending confirmation | Copolymer with polyethylene; confirm reference, calibre and needle geometry against IFU |
| Laboratory Aragó | Blue polypropylene monofilament, ½ circle cylindrical (conical) needle 40 mm, USP 1 | 37096 (C30, 1 × 100 cm) | Comparable by category (verified in USP 1 calibre) | Material, colour and needle geometry match; the calibre (USP 1 vs USP 2) and length differ |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | Consult code according to gauge and needle | Pending confirmation | Sector family with same clinical indication; not interchangeable 1:1 without technical verification |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands. Comparisons with PROLENE®, Premilene®/Optilene®, Surgipro™ and SERAPREN® are functional, at category level, and must be confirmed against the technical data sheet or the IFU of each manufacturer before use in tendering. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Tissue to suture: the HR needle with conical Taperpoint point is suitable for soft, vascular and poorly distensible planes that require non-cutting penetration (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider triangular point profiles (reverse cutting) from the same PREMISUT range.
- Needle size: the 40 mm HR is a needle of generous length, indicated for wide suture planes or deep tissue; for smaller areas, needles from the same family are available (HR 35, HR 30…).
- Gauge: USP 2 offers high tension for tissues that require larger diameter and load-bearing ligatures; for less demanding planes, USP 1 (AM732HR4001) or USP 0 (AM732HR4010) is available with the same HR 40 needle.
- Presentation: if you prefer a single-intervention package opening and a needle with improved penetration, consider the Prime version with single thread P732HR4002 (AMP732HR4002) or the double-thread version P732HR4002.2 (AMP732HR4002.2).
- Sterility verification: sterile product by ethylene oxide, single-use; check the integrity of the blister and the expiry date before each use and keep the reference 732HR4002 and the batch number for traceability in the operating theatre and in case of complaint.





Reviews