Description
1. Commercial Introduction
The polypropylene suture Premisut Prime VisiBlack that Cahnos makes available to surgical departments, purchasing centres and tenders is the reference solution when a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction is required. This presentation incorporates a double ½ circle taper point needle (Taperpoint) of 20 mm in VisiBlack technology (black needle), USP 4/0 gauge and a blue strand of 90 cm: a versatile, high-visibility configuration widely used in soft tissue approximation, ligatures and cardiovascular, ophthalmology, vascular and neurosurgery procedures.
It is supplied sterile, ready for single use and with batch traceability, facilitating hospital stock management and submission to public tenders. Available under the factory reference P733HR2040-2VB (SKU Cahnos AMP733HR2040-2VB), kept unchanged: no digit may be added, removed or reordered when ordering or tendering. Price per box of 12 units.
2. Technical Explanation
Polypropylene is a linear synthetic polyolefin (propylene polymer) presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.
The ½ circular needle with taper point (Taperpoint) and cylindrical body penetrates soft and lax tissues by separating the fibres without cutting them, making it especially suitable for vascular, cardiovascular tissue and delicate structures. The HR20 profile of 20 mm offers excellent control in superficial and medium-thickness surgical fields. VisiBlack technology incorporates a black needle that dramatically improves its contrast against the surgical field, even in environments with high lighting or bleeding, facilitating visualisation of the tip and the penetration path. The double-needle format (2×HR20) allows continuous suture techniques and anastomosis with two armed ends without re-threading, optimising surgical time. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut Prime range (Cahnos S.L.).
| Parameter | Specification |
|---|---|
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament, smooth high-visibility surface |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| Gauge / USP size | USP 4/0 (metric 1.5); diameter 0.15 – 0.199 mm (according to USP Pharmacopoeia) |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Blue (high visibility) |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Taper point (Taperpoint), cylindrical body |
| Needle size | 20 mm (HR20 Prime profile) × 2 needles |
| Configuration | Double needle (2 × HR20) |
| Needle technology | VisiBlack – high-visibility black needle |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology, vascular and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P733HR2040-2VB |
| Reference Cahnos (SKU) | AMP733HR2040-2VB |
Gauge equivalence according to USP (indicative):
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 4/0 | 1.5 | 0.15 – 0.199 mm (non-absorbable suture) |
Variants of the Premisut Prime family – polypropylene 1/2 circle taper point, 90 cm, blue:
| Configuration | Cahnos / factory reference | Observations |
|---|---|---|
| 2×HR20 – 90 cm, 4/0, black VisiBlack needle | AMP733HR2040-2VB (P733HR2040-2VB) | Product of this data sheet |
| 2×HR25 – 90 cm, 4/0, black VisiBlack needle | AMP733HR2540-2VB (P733HR2540-2VB) | HR25 needle of 25 mm for medium-depth fields |
| 2×HR16 – 90 cm, 4/0, black VisiBlack needle | AMP733HR1640-2VB (P733HR1640-2VB) | HR16 needle of 16 mm for reduced or paediatric fields |
| 2×HR25 – 90 cm, 4/0, standard Prime needle | AMP733HR2540-2 (P733HR2540-2) | Same product; needle without VisiBlack finish |
| 2×HR25 – 90 cm, 4/0, normal quality | AM733HR2540-2 (733HR2540-2) | Standard range with grooved needle |
| HR25 – 75 cm, single needle, 4/0 | AM732HR2540 (732HR2540) | Single HR25 needle and 75 cm thread |
| 2×HRT25 – 90 cm, trocar point (tapercut) | AMP733HRT2540-2 (P733HRT2540-2) | Trocar point for tissues with greater resistance |
| 2×HR20 – 90 cm, 5/0, black VisiBlack needle | AMP733HR2050-2VB (P733HR2050-2VB) | Finer gauge for microsurgery |
4. Equivalences and Cross-References
The reference P733HR2040-2VB corresponds to the official nomenclature of the Premisut Prime range (2×HR20 profile, double 20 mm needle with VisiBlack technology, USP 4/0 gauge and blue 90 cm thread). Cahnos markets the product keeping the factory reference unchanged. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | 1/2 circle taper point 2×HR25, 4/0, blue, 90 cm (black VisiBlack needle) | AMP733HR2540-2VB (P733HR2540-2VB) | Direct range equivalent | Same material, gauge, colour and length; only the needle size varies (HR25 of 25 mm versus HR20 of 20 mm for this reference) |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, 4/0, 90 cm, double needle SH half circle taper point of 26 mm | 8521H | Comparable by category, not interchangeable 1:1 | Code verified in Ethicon catalogue and authorised distribution: material, gauge, colour, double needle and 90 cm match; SH needle of 26 mm versus HR20 of 20 mm; presentation in box of 36 units |
| B. Braun (Aesculap) | Premilene® – blue monofilament polypropylene, 4/0 (1.5), 90 cm, 2×HR26 CV | C2090907 (G2090907) | Comparable by category, not interchangeable 1:1 | Code verified in B. Braun catalogue and medical device registration (GUDID): same material, gauge, colour and double taper point needle; HR26 needle of 26 mm versus HR20 of 20 mm |
| B. Braun (Aesculap) | Optilene® – polypropylene-polyethylene copolymer, blue, 4/0 (1.5), 90 cm, 2×HR26 CV RCP | C3090907 | Comparable by category, not interchangeable 1:1 | Code verified in B. Braun catalogue: same gauge and double needle configuration; differs in material (copolymer of polypropylene and polyethylene versus pure polypropylene) and 26 mm needle |
| DemeTECH | DemeLENE™ – polypropylene, DSH half circle round body 26 mm, blue, USP 4-0, 36 in (90 cm) | PM1094026C0P | Comparable by category, not interchangeable 1:1 | SKU verified in official DemeTECH store: same material, gauge, colour and 90 cm; DSH needle of 26 mm round body versus HR20 of 20 mm |
| Serag-Wiessner | SERAPREN® – blue monofilament polypropylene, USP 4/0 (EP 1.5), 90 cm, double needle 2×HR-26 | CP15443C | Comparable by category, not interchangeable 1:1 | Reference verified in official SERAPREN catalogue: same material, gauge and length; HR26 needle of 26 mm versus HR20 of 20 mm; presentation in box of 24 units |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references the reference P733HR2040-2VB with other brands; comparisons with PROLENE®, Premilene®, Optilene®, DemeLENE™ or SERAPREN® are functional, at category level, and not interchangeable 1:1 without prior technical validation against the technical data sheet or IFU of each manufacturer before use in tendering or direct substitution. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
Tissue to suture: the conical point needle (Taperpoint) with cylindrical body is the choice for soft, lax and vascular tissues, as it separates the fibres without cutting them (optimal in cardiovascular and vascular surgery). If the protocol requires passing through more fibrous tissues or calcified adventitia, consider the Tapercut trocar point variant from the same range (AMP733HRT2540-2 in 4/0).
Needle size: the HR20 of 20 mm is indicated for more superficial, reduced or paediatric fields, with excellent tip control. If you need greater reach in medium-depth planes, the HR25 (AMP733HR2540-2VB) from the same VisiBlack family is available; for even more reduced fields, the HR16 (AMP733HR1640-2VB).
Double needle format: the 2×HR20 presentation allows continuous suture and anastomosis techniques with two armed ends without re-threading, optimising surgical time and material consumption.
Gauge: USP 4/0 (metric 1.5) is very versatile for soft, vascular and cardiovascular tissue. For greater mechanical demands, the same VisiBlack family is available in USP 3/0 (AMP733HR2530-2VB) and 2/0 (AMP733HR2520-2VB); for delicate tissues or microsurgery, in 5/0 (AMP733HR2050-2VB and AMP733HR2550-2VB).
VisiBlack technology: the black needle of this reference offers superior contrast on the surgical field, reducing needle localisation time and improving precision in deep planes or with intense lighting; it is the recommended choice when needle visibility is critical.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P733HR2040-2VB and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.