1. Commercial Introduction
The polypropylene suture PREMISUT PRIME is the reference choice for operating theatres, purchasing departments and tenders that require a non-absorbable thread with predictable behaviour, high tensile strength and minimal tissue reaction. This presentation in USP 1 gauge incorporates a ½ circle needle with cylindrical body and conical point (Taperpoint) of 40 mm (HR 40 Prime profile) and a blue strand of 75 cm: a solid and versatile configuration, highly valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues with medium-high tension.
It is supplied sterile, ready for single use, in a box of 12 units with individual envelopes and batch traceability. It is marketed under the factory reference P732HR4001 (SKU AMP732HR4001), kept without altering characters.
2. Technical Explanation
Polypropylene is a linear synthetic polyolefin (isotactic polymer) presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. As it is non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR 40 Prime needle (½ circle, cylindrical body with taperpoint conical point of 40 mm) penetrates soft and poorly distensible tissues by separating the fibres without cutting them, which reduces tissue trauma and is especially valuable in vascular structures, arterial adventitia and deep planes. The USP 1 gauge (metric EP 4) provides high tensile strength, suitable for areas subjected to medium-high tension such as the abdominal wall, fascia or vascular ligatures. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range, needle with improved finish) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament (smooth surface, without interstices) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| Gauge / USP size | USP 1 (metric EP 4); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.350 – 0.399 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Conical (Taperpoint), HR profile |
| Needle size | 40 mm (HR 40 Prime profile) |
| Configuration | Single needle (1 × HR 40) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P732HR4001 |
| Reference Cahnos (SKU) | AMP732HR4001 |
4. Equivalences and Cross-References
The blue non-absorbable polypropylene monofilament is one of the most standardised permanent suture families on the market (type ‘Prolene’). Reference P732HR4001 corresponds to the official nomenclature of the Premisut Prime range (HR 40 Prime profile, single needle, USP 1 gauge, 75 cm thread) and Cahnos markets it without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1 without prior technical validation against the technical data sheet and IFU of each manufacturer.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime (Cahnos) | Polypropylene Prime – ½ circle conical point HR 40, USP 1, blue, 75 cm | P732HR4001 / AMP732HR4001 | Exact reference equivalence (identical) | Official reference of the product analysed in this data sheet. |
| Premisut Prime (Cahnos) | Polypropylene Prime – HR 35, USP 2/0, blue, 75 cm | P732HR3520 / AMP732HR3520 | Configuration equivalent within the same system | Same family, colour and length; HR 35 mm needle and 2/0 calibre for less demanding tissues. |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, USP 1 (EP 4), 75 cm, HR 40 needle of 40 mm, ½ circle, conical point | C2090200 (premilene 1 HR40S BL) | Functional equivalence by specifications (no official cross-reference table) | High match: material, gauge (EP 4), length of 75 cm, HR 40 needle of 40 mm in ½ circle with conical point (round bodied, taper point). They differ in needle finish and commercial presentation (box of 12 vs. 36 units); verify batch and IFU. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 1, 75 cm, CT-1 needle of ½ circle, conical point | 8425H | Comparable at category level (not interchangeable 1:1) | Material, gauge, colour and length match; the CT-1 needle is 36.4 mm compared to the HR 40 of 40 mm and the presentation is 36 units. Confirm needle measurement and CE/MDR traceability against IFU. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene copolymer with polyethylene, blue | 1:1 reference not verified in this consultation | Comparable by category / pending confirmation | Same clinical indication; copolymeric material (not pure polypropylene). Confirm gauge, length and needle geometry in the official catalogue before any substitution. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene® or Surgipro™ II are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
- Tissue to suture: the HR needle with conical point (taperpoint) is indicated for soft, vascular and delicate structures where the aim is to separate the fibres without cutting them (cardiovascular surgery, ophthalmology, anastomosis and neurosurgery). For planes requiring firmer penetration (skin, fascia), consider trocar or triangular point profiles from the same Premisut Prime range.
- Needle measurement: the HR 40 of 40 mm is suitable for surgical fields of medium depth and tissues of moderate tension. If you require a shorter needle with the same conical point criterion, the HR 35 variant is available (ref. AMP732HR3520) and smaller needles of the family; for deep planes, the range offers HR 48 in single or double needle presentations (2×HR48, ref. AMP733HR4801-2 / AMP733HR4810-2).
- Gauge: USP 1 (metric 4) provides high tensile strength for thick tissues, fascias and vascular ligatures. If the protocol requires a smaller diameter, the same polypropylene family Premisut Prime offers smaller gauges (2/0, 3/0, 4/0, 5/0 and smaller) with the same point criterion.
- Prime range: the Premisut Prime line maintains the geometry of the standard version with improved needle finish (superior penetration); useful when the protocol requires premium penetration quality in delicate tissues.
- Prior verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference P732HR4001 and the batch number for traceability in the operating theatre and in case of complaint. For special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team of Cahnos.