Description
1. Commercial Introduction
The Premisut Prime polypropylene suture in double needle presentation is the choice of the professional who needs a high-performance non-absorbable thread for delicate and precise surgical planes. This reference combines an uncoated polypropylene monofilament, dyed in high-visibility blue, with two ½ circle needles, cylindrical body and 8 mm Taperpoint conical point (2xHR8 Prime profile), in USP 7/0 gauge and 60 cm thread: a configuration of maximum fineness designed for cardiovascular surgery, ophthalmology, neurosurgery and microsurgery.
Sterile, single-use product, with batch traceability and presented in a box of 12 units in individual sachets, it is ideal for surgical services, purchasing centres, public tenders and hospital supply agreements that seek constant quality and excellent value for money. It is marketed keeping the factory reference P736HR870-2 (SKU Cahnos AMP736HR870-2) without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) that is presented as an uncoated monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period according to USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months. The fluted blue colour guarantees optimal visibility on the surgical field.
The ½ circle needle with cylindrical body and 8 mm Taperpoint conical point passes through tissue separating fibres without cutting them, reducing trauma to delicate and thin-walled vascular structures, being especially suitable for microsurgery and very restricted surgical fields. The ½ circle radius offers excellent control in depth, while the double needle configuration allows continuous sutures or repositioning of the thread without rethreading, reducing the opening of packaging per intervention. Sterilisation is carried out by ethylene oxide (EO); the product is single-use and not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut Prime range (Cahnos S.L.).
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament, uncoated (≥ 99.5% polypropylene, ≤ 0.5% phthalocyanine blue) |
| Thread structure | Monofilament, fluted blue |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 7/0 (metric EP 0.5); conforming to USP gauges and European Pharmacopoeia |
| Thread diameter | 0.050 – 0.069 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture) |
| Thread length | 60 cm (double needle on the same strand) |
| Needle shape | ½ circular (1/2 circle), cylindrical body |
| Needle type | Taperpoint conical point (HR profile) |
| Needle size | 8 mm – double needle presentation (2xHR8 Prime) |
| Configuration | Double needle (2 armed needles) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P736HR870-2 |
| Reference Cahnos (SKU) | AMP736HR870-2 |
Family Premisut Prime 2xHR8 (double needle ½ circle, 8 mm Taperpoint conical point, 60 cm fluted blue thread):
| USP size | Thread | Reference |
| 6/0 | 60 cm (double needle) | P736HR860-2 / AMP736HR860-2 |
| 7/0 | 60 cm (double needle) | P736HR870-2 / AMP736HR870-2 (this product) |
| 8/0 | 60 cm (double needle) | P736HR880-2 / AMP736HR880-2 |
4. Equivalences and Cross-References
Reference P736HR870-2 corresponds to the official nomenclature of the Premisut Prime range (2xHR8 profile, double ½ circular needle with 8 mm Taperpoint conical point, USP 7/0 gauge, 60 cm fluted blue thread). There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tenders or direct substitution. This short needle geometry (8 mm) is only fully safely interchangeable within the Premisut system itself.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 7-0, double needle RB-3 Taper Point ½ circle 11 mm, 60 cm | 8206H | Comparable by category (not interchangeable 1:1) | Code verified in official Ethicon catalogue: material, gauge, colour, ½ circle radius, Taper Point point, double needle and 60 cm length match; 11 mm needle vs 8 mm. Confirm CE/MDR traceability against IFU |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 7-0, double needle BV175-8 (BV-1) Taper Point ⅜ circle 9.3 mm, 60 cm | 8747H / EP8747H | Comparable by category (not interchangeable 1:1) | Code verified in official Ethicon catalogue: material, gauge, colour, conical point, double needle and 60 cm length match; ⅜ radius vs ½ circle and 9.3 mm needle vs 8 mm |
| Medtronic (Covidien) | Surgipro™ II – blue polypropylene/polyethylene copolymer, 7-0, double needle CVL ⅜ circle Taper Point, 60 cm | VP652MX | Comparable by category (not interchangeable 1:1) | Code verified in authorised distribution: gauge, colour, double needle and 60 cm match; copolymer material (not pure polypropylene), ⅜ circle radius and CVL needle vs HR8 |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 7/0 (0.5), double needle 2×DR10 CV, 60 cm | C2090714 (GUDID 04046963691356) | Comparable by category (not interchangeable 1:1) | Reference verified in GUDID/FDA and Aesculap catalogue: material, gauge, colour, double needle and length match; 10 mm needle and DR geometry vs HR8. Confirm arc in technical data sheet before substitution |
There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; comparisons with PROLENE®, Surgipro™ II or Premilene® are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tenders or direct substitution. Consult Cahnos’s technical department to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Tissue to suture: USP 7/0 gauge (metric 0.5) is one of the finest in the range, indicated for microsurgery and very delicate planes (ophthalmology, neurosurgery, cardiovascular surgery) and thin skin. The Taperpoint conical needle separates fibres without cutting them, ideal for lax, vascular and well-irrigated tissues; for firm or poorly distensible tissues consider trocar point (Tapercut) or reverse cutting profiles from the same Premisut range.
Needle size: the 8 mm HR is the shortest needle in the ½ circle family, designed for very restricted surgical fields. If the protocol allows a slightly larger needle, the same family offers the HR10 profile in 7/0 (P736HR1070-2 / AMP736HR1070-2) or the HR13 in 6/0.
Range variants in Cahnos: the same HR8 needle available in USP 6/0 (AMP736HR860-2) and USP 8/0 (AMP736HR880-2); if you prefer a ⅜ circle radius in 7/0 with conical point, see reference AMP736DR870-2; for maximum needle visibility in bleeding fields, the VisiBlack DR9 variant (AMP736DR970-2VB). Consolidating the supplier across the entire permanent suture portfolio enables volume B2B terms.
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P736HR870-2 and the batch number for traceability in the operating theatre and in case of complaint. For special B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.