Description
1. Commercial Introduction
The Premisut Prime polypropylene suture in double-needle presentation is the choice of the professional who needs a high-performance non-absorbable thread for delicate and precise surgical planes. This reference combines an uncoated polypropylene monofilament, dyed high-visibility blue, with two ½-circle needles, cylindrical body and 10 mm Taperpoint conical point (profile 2xHR10 Prime), in USP 6/0 gauge and a 60 cm suture: an ultra-fine configuration designed for approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery.
Sterile, single-use product with batch traceability, supplied in a box of 12 units in individual sachets, it is ideal for surgical departments, purchasing centres, public tenders and hospital supply agreements seeking consistent quality and excellent value for money. It is marketed under the factory reference P736HR1060-2 (SKU Cahnos AMP736HR1060-2) without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) supplied as an uncoated, non-grooved monofilament: as it has no interstices or wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence or sinus formation in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength over time in accordance with USP and European Pharmacopoeia gauges, and becomes gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months. The blue colour ensures optimal visibility on the surgical field.
The ½-circle needle with cylindrical body and 10 mm Taperpoint conical point passes through tissue by separating fibres without cutting them, reducing trauma to delicate, thin-walled vascular structures. The ½-circle radius offers excellent control in confined and deep surgical fields, while the double-needle configuration allows continuous sutures or repositioning of the strand without rethreading, reducing the number of packs opened per procedure. Sterilisation is by ethylene oxide (EO); the product is single-use and not resterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut Prime range (Cahnos S.L.).
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue (≥ 99.5% polypropylene, ≤ 0.5% phthalocyanine blue) |
| Thread structure | Monofilament, non-channeled |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 6/0 (metric 0.7); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.070 – 0.099 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture) |
| Thread length | 60 cm |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Taperpoint conical point (cylindrical body), HR profile |
| Needle size | 10 mm – double-needle presentation (2xHR10 Prime) |
| Configuration | Double needle (2 armed needles) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P736HR1060-2 |
| Reference Cahnos (SKU) | AMP736HR1060-2 |
Family Premisut Prime 2xHR10 (double needle ½ circle, Taperpoint conical point of 10 mm, blue thread):
| USP size | Thread | Reference |
| 5/0 | 60 cm (double needle) | P736HR1050-2 / AMP736HR1050-2 |
| 6/0 | 60 cm (double needle) | P736HR1060-2 / AMP736HR1060-2 (this product) |
| 7/0 | 60 cm (double needle) | P736HR1070-2 / AMP736HR1070-2 |
4. Equivalences and Cross-References
Reference P736HR1060-2 corresponds to the official nomenclature of the Premisut Prime range (profile 2xHR10, double ½-circle needle with 10 mm Taperpoint conical point, USP 6/0 gauge, 60 cm blue suture). There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tenders or direct substitution. This short needle geometry (10 mm) can only be safely interchanged within the Premisut system itself.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range (Cahnos) | Polypropylene 2xHR10 Prime, USP 6/0, blue, 60 cm | P736HR1060-2 / AMP736HR1060-2 | Reference of the analysed product | This data sheet; double ½-circle Taperpoint needle of 10 mm and double 60 cm thread |
| Premisut Prime range (Cahnos) | Polypropylene 2xHR10 Prime, USP 5/0, blue, 60 cm | P736HR1050-2 / AMP736HR1050-2 | Direct range equivalent | Same HR10 needle, Prime quality, radius and colour; only the gauge changes (5/0 versus 6/0) |
| Premisut Prime range (Cahnos) | Polypropylene 2xHR10 Prime, USP 7/0, blue, 60 cm | P736HR1070-2 / AMP736HR1070-2 | Direct range equivalent | Same HR10 needle and presentation; 7/0 gauge for microsurgery of maximum fineness |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 6/0, double needle RB-2 ½ circle Taper Point 13 mm, 75 cm | 8711H / EPM8711 | Comparable by category, not interchangeable 1:1 | Code verified in Ethicon catalogue and authorised distribution: material, gauge, colour, ½-circle radius, Taper Point point and double-needle configuration match; needle 13 mm vs 10 mm and length 75 cm vs 60 cm. Confirm CE/MDR traceability against IFU |
| Medtronic (Covidien) | Surgipro™ II – blue polypropylene/polyethylene copolymer, 6/0, Taper Point needle of 13 mm | VP706X / VP706X-2 | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution: gauge, colour and Taper Point point match; copolymer material (not pure polypropylene), 13 mm needle and presentation to be confirmed against IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 6/0 | Code 6/0 not verified in this query. | Comparable by category, not verified | Same base material and family confirmed in official B. Braun catalogue; confirm exact reference, needle radius and presentation (single/double needle) before use |
| Serag-Wiessner | SERAPREN® – blue polypropylene monofilament | Code 6/0 not verified in this query. | Not verified | Same base material; confirm code, needle and presentation in official catalogue before use |
Mandatory technical note: there is no equivalence table validated by the manufacturer cross-referencing this reference with other brands; comparisons with PROLENE®, Surgipro™ II, Premilene® or SERAPREN® are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tenders or direct substitution. Consult the Cahnos technical department to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Tissue to suture: USP 6/0 gauge (metric 0.7) is the microsurgery choice for very delicate planes (ophthalmology, neurosurgery, cardiovascular surgery) and thin skin. The Taperpoint conical needle separates fibres without cutting them, ideal for lax, vascular and well-perfused tissues; for firm or poorly distensible tissues consider trocar point (Tapercut) or reverse cutting profiles from the same Premisut range.
Needle size: the 10 mm HR is a short needle of maximum precision, ideal for very confined surgical fields. If the protocol allows a slightly larger needle, the same family offers the HR13 profile in 6/0 (AMP736HR1360-2, 60 cm; AMP732HR1360-2, 75 cm) or the shorter HR8 needle variant (AMP736HR860-2).
Presentation: the double-needle version in this data sheet reduces the number of packs opened per procedure and provides two 60 cm sutures for continuous sutures or repositioning without rethreading; if a more economical single needle per unit is required, see the 1x variants of the same range in the catalogue.
Other geometries of interest: if the protocol requires a ⅜-circle radius with conical point, the 2xDR13 family in 6/0 (AMP736DR1360-2) or the 2xDR9 VisiBlack for fine gauges (AMP736DR960-2VB, AMP736DR970-2VB) is available, allowing supplier consolidation across the entire permanent suture portfolio.
Sterility verification: sterile product by ethylene oxide and single-use; check the blister integrity and expiry date before each use and keep the reference P736HR1060-2 and batch number for traceability in the operating theatre and in case of complaint. For special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team at Cahnos.