Description
1. Commercial Introduction
The polypropylene suture Premisut Prime is the reference choice for operating theatres, purchasing departments and tenders that require a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that passes through tissue with total control. This presentation in USP 2/0 gauge, with a ½ circle grooved taper point needle of 35 mm (HR 35 Prime profile) and double blue thread of 75 cm (2×75 cm), is especially indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
It is supplied sterile and ready for individual use in a box of 12 units with batch traceability, facilitating hospital stock management and presentation to public tenders. Factory reference P732HR3520.2, marketed by Cahnos as SKU AMP732HR3520.2, maintaining the manufacturer’s official nomenclature without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as uncoated monofilament, dyed blue. As it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period and is gradually encapsulated by connective tissue, helping the wound for more than three months.
The HR 35 Prime needle (½ circle, cylindrical body and grooved taper point (taperpoint) of 35 mm) separates and displaces tissue fibres without cutting them, making it ideal for soft and vascular tissues that require controlled penetration and minimal injury; the grooved finish of the needle body and the Prime range steel facilitate smooth delivery during knotting. The double thread presentation allows optimal use per procedure. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Line | Premisut – Prime quality |
| Thread material | Polypropylene monofilament, uncoated, dyed blue (synthetic linear polyolefin, (C3H6)n) |
| Thread structure | Monofilament with ribbed needle (RHR 35 Prime profile) |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 2/0 (metric EP 3); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 2 threads of 75 cm per unit (2×75 cm) |
| Thread colour | Identifying blue, high visibility on the surgical field |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Taperpoint conical point (cylindrical body), ribbed (HR 35 profile) |
| Needle size | 35 mm (HR 35 Prime profile / RHR 35 ribbed prime) |
| Manufacturing quality | Prime (premium range, improved penetration needle) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P732HR3520.2 |
| Reference Cahnos (SKU) | AMP732HR3520.2 |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
Gauge equivalence according to USP/EP standard (non-absorbable suture):
| USP size | Metric size | Approximate thread diameter |
| 2/0 | 3 | 0.30 – 0.349 mm |
4. Equivalences and Cross-References
Reference P732HR3520.2 corresponds to the official nomenclature of the Premisut Prime range (grooved HR 35 Prime profile, double thread of 75 cm, USP 2/0 gauge, blue colour) and Cahnos markets it without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this product with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene HR 35 Prime, USP 2/0, blue, 1×75 cm | P732HR3520 / AMP732HR3520 | Configuration equivalent within the same system | Same grooved HR 35 needle and USP 2/0 gauge; the presentation changes to a single thread (1×75 cm). |
| Cahnos (Premisut) | Polypropylene HR 35, USP 2/0, blue, 1×75 cm (standard) | 732HR3520 / AM732HR3520 | Direct equivalent within the same family | Same measurements and material; standard quality needle versus Prime. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 2/0, 75 cm, CT-1 ½ circle taper point needle | 8423H | Comparable by category (not interchangeable 1:1) | Material, gauge, colour and length match (75 cm); the CT-1 needle is 36 mm and not grooved versus the grooved HR 35 of 35 mm. Verified in official Ethicon catalogue. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene, USP 2/0, 75 cm, CT-2 taper point needle | 8411H | Comparable by category (not interchangeable 1:1) | Same gauge, colour and length; CT-2 needle of 26 mm versus HR 35 of 35 mm. Confirm needle measurement and finish in IFU. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene, USP 2/0, blue, V-26 ½ circle taper point | VP843 | Comparable by category (not interchangeable 1:1) | Same gauge and taper point; V-26 needle of 26 mm and 90 cm thread (not 2×75 cm). Copolymer material; verify in official Medtronic catalogue. |
| Corza Medical | Sharpoint – blue polypropylene, USP 2/0, 75 cm, CT-2 taper point of 26 mm | J8411N | Comparable by category (not interchangeable 1:1) | Same gauge, colour and length; shorter needle (26 mm) and presentation of 12/24 units. Verify CE/MDR traceability. |
| DemeTECH | DemeLENE® – polypropylene, USP 2/0, blue thread of 75 cm, DCT-2 round body ½ circle needle | PM292026B1P | Comparable by category (not interchangeable 1:1) | Same gauge and length; DCT-2 needle of 26 mm round body, without grooved channel. Verified in official DemeTECH store. |
| B. Braun | Dafilon® / Premilene® – blue polypropylene, USP 2/0, 75 cm | C0935360 (Dafilon DS24) | Comparable by category (not interchangeable 1:1) | Same gauge, colour and length; confirm DS24 needle geometry and length in official B. Braun catalogue before use. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this product with other brands; comparisons with PROLENE®, Surgipro™ II, Sharpoint, DemeLENE® or Dafilon®/Premilene® are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Tissue to suture: the grooved taper point HR needle is indicated for soft, vascular and flat tissues with low distensibility that require penetration without cutting (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider trocar point (HRT) or triangular profiles from the same Premisut Prime range.
- Needle size: the 35 mm HR is ideal for medium-depth fields. If a shorter needle is required, the HR 30 (ref. AMP732HR3020.2) or HR 25 (ref. AMP732HR2520.2) is available in 2/0 and double thread 2×75 cm; for larger planes, the HR 40 (ref. AMP732HR4001.2 / AMP732HR4002.2).
- Gauge: USP 2/0 offers a balance between handling and strength for vascular ligatures and soft tissues. If the protocol requires a smaller diameter, the same Premisut Prime family offers HR 35 in 3/0 (ref. AMP732HR3530.2) or in 0 (ref. AMP732HR3510.2).
- Presentation: the double-thread 2×75 cm version optimises usage per procedure. If you prefer one package opening per use, consider the single-thread version P732HR3520 (SKU AMP732HR3520) or the standard alternative without the Prime range AM732HR3520.
- Prime range: the Premisut Prime line maintains the geometry of the standard version with an improved needle finish (superior penetration); useful when the protocol requires premium quality in delicate tissues.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732HR3520.2 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews