Description
1. Product Presentation
The PREMISUT PRIME polypropylene suture is the reference choice for surgery departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation incorporates double needle ½ circle, conical point (Taperpoint), 25 mm (profile 2xHR25), USP 3/0 gauge and ribbed blue thread of 90 cm per side (2 x 90 cm), a configuration especially valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
It is supplied sterile, ready for immediate use, in a box of 12 units with individual envelopes and batch traceability. Available at Cahnos under the factory reference P733HR2530.2-2 (SKU AMP733HR2530.2-2), kept unchanged.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as a non-coated monofilament: lacking interstices and wick effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. As it is non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR needle (½ circle, cylindrical body) with Taperpoint conical point allows traversing soft and friable tissues with minimal trauma, without cutting the suture bed: it is the ideal geometry for parenchyma, fatty tissue and thin-walled vascular structures. The double needle format (2x) allows continuous suture techniques and anastomosis with two armed ends, without re-threading, optimising surgical time. The high-visibility ribbed blue thread facilitates identification of the thread and the knot on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable. The Prime quality adds a premium needle finish with a ribbed body and improved penetration compared to the standard Premisut quality.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / line | Premisut Prime (polypropylene, premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament (fluted surface for high visibility) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 3/0 (metric EP 2; diameter 0.20 – 0.249 mm); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 2 x 90 cm (2 threads per unit, double-armed) |
| Thread colour | Ribbed identification blue |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Taperpoint conical, HR profile |
| Needle size | 25 mm (2 x HR 25) |
| Configuration | Double needle (2 x HR) |
| Manufacturing quality | Prime (premium needle finish) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P733HR2530.2-2 |
| Reference Cahnos (SKU) | AMP733HR2530.2-2 |
3.2. Premisut 2xHR25 family (½ circle, cylindrical body, conical point) and range variants
| Needle profile | Presentation | Reference |
|---|---|---|
| 2xHR 25 (Prime) | 2 x 90 cm, USP 3/0 (product analysed) | P733HR2530.2-2 / AMP733HR2530.2-2 |
| 2xHR 25 (standard) | 2 x 90 cm, USP 3/0 | 733HR2530-2 / AM733HR2530-2 |
| 2xHR 25 (standard) | 2 x 90 cm, USP 4/0 | 733HR2540-2 / AM733HR2540-2 |
| 2xHR 25 (standard) | 2 x 90 cm, USP 2/0 | 733HR2520-2 / AM733HR2520-2 |
| HR 25 (standard, single needle) | 1 x 75 cm, USP 3/0 | 732HR2530 / AM732HR2530 |
4. Equivalences and Cross-References
The reference P733HR2530.2-2 corresponds to the official nomenclature of the Premisut Prime range (profile 2xHR25, double needle, USP 3/0 gauge, blue thread 2 x 90 cm). Below are detailed the references from the Cahnos catalogue with identical or very close configuration, as well as families from other manufacturers in the sector. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons between brands are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Differences / Notes |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene 1/2 circle 2xHR25, USP 3/0, blue, 90 cm | P733HR2530.2-2 / AMP733HR2530.2-2 | Exact reference equivalence (current product) | Official reference of the analysed product |
| Cahnos (Premisut) | Polypropylene 1/2 circle 2xHR25, USP 3/0, blue, 90 cm | 733HR2530-2 / AM733HR2530-2 | Direct equivalent (same system) | Same needle geometry, gauge, colour and length; the premium needle finish varies (Prime version vs. standard) |
| Cahnos (Premisut) | Polypropylene 1/2 circle 2xHR25, USP 4/0, blue, 90 cm | 733HR2540-2 / AM733HR2540-2 | Configuration equivalent (same system) | Same needle 2xHR25 and length; gauge changes to USP 4/0 |
| Cahnos (Premisut) | Polypropylene 1/2 circle 2xHR25, USP 2/0, blue, 90 cm | 733HR2520-2 / AM733HR2520-2 | Configuration equivalent (same system) | Same needle 2xHR25 and length; gauge changes to USP 2/0 |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 3/0, 90 cm, double needle ½ circle conical point | Code for 2×25 mm format pending confirmation | Comparable by category (not interchangeable 1:1) | Same clinical indication and double needle type; verify needle length and point in official catalogue before substituting |
| B. Braun | Optilene® / Premilene® – blue polypropylene (and polyethylene in Optilene) monofilament, double needle ½ circle | Pending confirmation for 2xHR25 USP 3/0 (in range: C3090002 for 2xHR30 USP 2/0) | Comparable by category (not interchangeable 1:1) | Matches material, colour, gauge and double needle in range variants; validate needle size, composition (copolymer) and Racepack packaging against IFU |
| Medtronic (Covidien) | Surgipro™ II – polypropylene with polyethylene monofilament, blue | Pending confirmation | Pending confirmation | Copolymer material (not pure polypropylene); no public code has been verified for double conical needle 2×25 mm USP 3/0 2×90 cm |
Mandatory technical note: there is no equivalence table validated by the manufacturer for the Premisut line compared to other brands. Consult the technical department of Cahnos before using any substitution in tenders or surgical protocols.
5. Selection tips and variants of interest
Conical point (Taperpoint): choose this configuration for soft, friable or delicate tissues (parenchyma, fat, thin-walled vascular structures); the cylindrical body and conical point minimise tissue trauma. For tissues with some fibrosis or resistance, consider trocar point (tapercut) variants from the same family.
USP 3/0 gauge: offers an excellent balance between strength and fineness, widely used in cardiovascular, vascular, ophthalmology and soft tissue surgery. For finer tissues, the 4/0 is available on the same needle (ref. 733HR2540-2) and for greater strength the 2/0 (ref. 733HR2520-2).
Needle length: the 25 mm HR is ideal for superficial and medium-thickness planes; if greater reach is needed in deep fields, consider the 30 mm HR from the same Prime range (ref. P733HR3020-2).
Double needle 2×90 cm: designed for continuous sutures and anastomoses with two armed ends, without re-threading; if you prefer a single 75 cm thread with a single needle, choose the 732HR2530 variant.
Prime range: maintains the same needle geometry as the standard version with a premium finish (improved sharpening, ribbed body and penetration). Always verify the full reference (needle 2xHR25, USP gauge 3/0 and length 2×90 cm) on the packaging, as well as the integrity of the blister and the expiry date before each use. Single-use product, not re-sterilisable.





Reviews
There are no reviews yet.