Description
1. Commercial Introduction
The polypropylene suture Premisut Prime in double-needle presentation is the choice of the professional who needs a high-performance non-absorbable thread for delicate and precise surgical planes. This reference combines an uncoated polypropylene monofilament, dyed blue for high visibility, with two ½-circle needles, cylindrical body and 10 mm Taperpoint conical point (2xHR10 Prime profile), in USP gauge 5/0 and 60 cm thread: a configuration designed for approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery.
Sterile, single-use product with batch traceability, presented in a box of 12 units in individual sachets, it is ideal for surgical services, purchasing centres, public tenders and hospital supply agreements that seek consistent quality and excellent value for money. It is marketed keeping the factory reference P736HR1050-2 (SKU Cahnos AMP736HR1050-2) without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) that is presented as an uncoated, non-grooved monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, supporting the wound for more than three months.
The ½-circle needle with cylindrical body and 10 mm Taperpoint conical point passes through tissue separating the fibres without cutting them, which reduces trauma to delicate and thin-walled vascular structures. The ½-circle radius offers excellent control in reduced and deep surgical fields, while the double-needle configuration allows continuous sutures or repositioning of the strand without rethreading, reducing the opening of packaging per intervention. Sterilisation is carried out by ethylene oxide (EO); the product is single-use and not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut Prime range (Cahnos S.L.).
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue (≥ 99.5% polypropylene, ≤ 0.5% phthalocyanine blue) |
| Thread structure | Monofilament, non-channeled |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 5/0 (metric EP 1.0); conforming to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.100 – 0.149 mm (according to USP Pharmacopeia, synthetic non-absorbable suture) |
| Thread length | 60 cm |
| Thread colour | Identification blue (high visibility in the surgical field) |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Taperpoint conical point (cylindrical body), HR profile |
| Needle size | 10 mm – double-needle presentation (2xHR10 Prime) |
| Configuration | Double needle (2 armed needles) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P736HR1050-2 |
| Reference Cahnos (SKU) | AMP736HR1050-2 |
Family Premisut Prime 2xHR10 (double needle ½ circle, 10 mm Taperpoint conical point, blue thread):
| USP size | Thread | Reference |
| 5/0 | 60 cm (double needle) | P736HR1050-2 / AMP736HR1050-2 (this product) |
| 6/0 | 60 cm (double needle) | P736HR1060-2 / AMP736HR1060-2 |
| 7/0 | 60 cm (double needle) | P736HR1070-2 / AMP736HR1070-2 |
4. Equivalences and Cross-References
Reference P736HR1050-2 corresponds to the official nomenclature of the Premisut Prime range (2xHR10 profile, double ½-circle needle with 10 mm Taperpoint conical point, USP gauge 5/0, blue 60 cm thread). There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. This short needle geometry (10 mm) is only safely interchangeable within the Premisut system itself.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut Prime range (Cahnos) | Polypropylene 2xHR10 Prime, USP 5/0, blue, 60 cm | P736HR1050-2 / AMP736HR1050-2 | Reference of the analysed product | This data sheet; double ½-circle Taperpoint needle of 10 mm and double 60 cm thread |
| Premisut Prime range (Cahnos) | Polypropylene 2xHR10 Prime, USP 6/0, blue, 60 cm | AMP736HR1060-2 | Direct range equivalent | Same HR10 needle, Prime quality, radius and colour; only the gauge changes (6/0 vs 5/0) |
| Premisut Prime range (Cahnos) | Polypropylene 2xHR10 Prime, USP 7/0, blue, 60 cm | AMP736HR1070-2 | Direct range equivalent | Same HR10 needle and presentation; 7/0 gauge for microsurgery of maximum fineness |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 5/0, double needle RB-1 ½ circle Taper Point 17 mm, 90 cm | 8556H | Comparable by category, not interchangeable 1:1 | Code verified in Ethicon catalogue and authorised distribution: material, gauge, colour, ½-circle radius, Taper Point point and double-needle configuration match; needle of 17 mm versus 10 mm and length of 90 cm versus 60 cm. Confirm CE/MDR traceability against IFU |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 5/0, double needle RB-2 ½ circle Taper Point 13 mm, 75 cm | 8710H | Comparable by category, not interchangeable 1:1 | Code verified in Ethicon catalogue and authorised distribution: material, gauge, colour, radius and point match; needle of 13 mm versus 10 mm and length of 75 cm versus 60 cm |
| Medtronic (Covidien) | Surgipro™ II – blue polypropylene/polyethylene copolymer, 5/0, Taper Point needle | 5/0 code to be confirmed | Comparable by category, not verified | Copolymeric material (not pure polypropylene) and different needle geometry; confirm exact reference, radius and needle size against IFU before use |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 5/0 | 5/0 code to be confirmed | Comparable by category, not verified | Same base material and family confirmed in official B. Braun catalogue; confirm exact reference, needle and presentation (single/double needle) before use |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Surgipro™ II or Premilene® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Tissue to suture: USP gauge 5/0 (metric 1.0) offers the balance between fineness and strength for soft tissues, vascular planes and thin skin. The Taperpoint conical needle separates the fibres without cutting them, ideal for lax, friable and well-irrigated tissues; for firm or poorly distensible tissues consider trocar point (Tapercut) or reverse cutting profiles from the same Premisut range.
Needle size: the 10 mm HR is a short needle of maximum precision, ideal for very reduced surgical fields (cardiovascular, ophthalmology, microsurgery). If the protocol allows a slightly larger needle, the same family offers the HR13 profile in 5/0 (AMP736HR1350-2, 60 cm; AMP732HR1350-2, 75 cm) or with VisiBlack black needle finish (AMP732HR1350-2VB).
Presentation: the double-needle version of this data sheet reduces the opening of packaging per intervention and provides two 60 cm threads for continuous sutures or repositioning without rethreading. For greater thread travel with a longer needle, reference AMP733HR1650-2 (2xHR16, 90 cm) extends the useful length in extensive continuous sutures.
Other geometries of interest: if the protocol requires a ⅜-circle radius with conical point, the 2xDR13 family (AMP736DR1350-2) or the 2xDR9 VisiBlack for fine gauges (AMP736DR960-2VB, AMP736DR970-2VB) is available, allowing supplier consolidation across the entire permanent suture portfolio.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P736HR1050-2 and the batch number for traceability in the operating theatre and in case of complaint. For special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team of Cahnos.