Description
1. Product Presentation
The PREMISUT PRIME polypropylene suture is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation incorporates a double ½ circular needle with conical point (Taperpoint) of 30 mm (profile 2xHR30), gauge USP 2/0 and a fluted blue thread of 90 cm per side (2 x 90 cm), a configuration especially valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
It is supplied sterile, ready for immediate use, in a box of 12 units with individual sachets and batch traceability. Available at Cahnos with the factory reference P733HR3020-2 (SKU AMP733HR3020-2), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as a non-coated monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. As it is non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR needle (½ circle, cylindrical body) with a Taperpoint conical point allows soft and friable tissues to be traversed with minimal trauma, without cutting the suture bed: it is the ideal geometry for parenchyma, fatty tissue and thin-walled vascular structures. The double needle format (2x) allows continuous suture techniques and anastomosis with two armed ends, without re-threading, optimising surgical time. The highly visible fluted blue thread facilitates identification of the thread and knot on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / line | Premisut Prime (polypropylene, premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament (fluted surface for high visibility) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 2/0 (metric EP 3); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 2 x 90 cm (1 thread per unit, double-armed) |
| Thread colour | Ribbed identification blue |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Taperpoint conical, HR profile |
| Needle size | 30 mm (2 x HR 30) |
| Configuration | Double needle (2 x HR) |
| Manufacturing quality | Prime (premium needle finish) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | P733HR3020-2 |
| Reference Cahnos (SKU) | AMP733HR3020-2 |
3.2. Family Premisut 2xHR30 (½ circle, cylindrical body, conical point) and range variants
| Needle profile | Presentation | Reference |
|---|---|---|
| 2xHR 30 (standard) | 2 x 90 cm, USP 2/0 | 733HR3020-2 / AM733HR3020-2 |
| 2xHR 30 (Prime) | 2 x 90 cm, USP 2/0 (analysed product) | P733HR3020-2 / AMP733HR3020-2 |
| 2xHR 30 (standard) | 2 x 90 cm, USP 3/0 | 733HR3030-2 / AM733HR3030-2 |
| HR 30 (standard, single needle) | 1 x 75 cm, USP 2/0 | 732HR3020 / AM732HR3020 |
| 2xHRT 30 (standard, trocar point) | 2 x 90 cm, USP 2/0 | 733HRT3020-2 / AM733HRT3020-2 |
4. Equivalences and Cross-References
Reference P733HR3020-2 corresponds to the official nomenclature of the Premisut Prime range (profile 2xHR30, double needle, USP 2/0 gauge, blue thread of 2 x 90 cm). The following details the references of the Cahnos catalogue itself with identical or very similar configuration, as well as families from other manufacturers in the sector. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons between brands are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Differences / Notes |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene 1/2 circle 2xHR30, USP 2/0, blue, 90 cm | P733HR3020-2 / AMP733HR3020-2 | Exact reference equivalence (current product) | Official reference of the analysed product |
| Cahnos (Premisut) | Polypropylene 1/2 circle 2xHR30, USP 2/0, blue, 90 cm | 733HR3020-2 / AM733HR3020-2 | Direct equivalent (same system) | Same needle geometry, gauge, colour and length; the premium finish of the needle varies (Prime version versus standard) |
| Cahnos (Premisut) | Polypropylene 1/2 circle 2xHR30, USP 3/0, blue, 90 cm | 733HR3030-2 / AM733HR3030-2 | Configuration equivalent (same system) | Same 2xHR30 needle and length; the gauge changes to USP 3/0 |
| B. Braun | Optilene® – blue monofilament, USP 2/0 (metric 3), 90 cm, double needle 2xHR30 Easyslide ½ circle | C3090002 (verified in catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | Material, gauge, colour, double needle and HR30 needle size match; Racepack packaging system; validate IFU and CE/MDR traceability |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 2/0, 90 cm, double needle CC-30 TAPERCUT ½ circle of 31 mm | W8850 (verified in authorised distribution; box of 12 units) | Comparable by category (not interchangeable 1:1) | Double needle and length match; trocar point (Tapercut) versus conical point (Taperpoint) and 31 mm needle versus 30 mm |
| Medtronic (Covidien) | Surgipro™ II – polypropylene monofilament with polyethylene, blue, USP 2/0, 90 cm (36 inches) | VP977 (verified in authorised distribution; box of 36 units) | Comparable by category (not interchangeable 1:1) | Copolymer material (polypropylene with polyethylene, not pure polypropylene); KV-7 tapercutting needle with trocar point versus conical point; pack of 36 units |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 2/0, 75 cm, HR30 Easyslide needle ½ circle conical point | C2090047 (verified in B. Braun catalogue; 75 cm variant) | Pending confirmation for 2×90 cm | 75 cm variant with conical HR30 needle confirmed; code for double needle 2×90 cm USP 2/0 pending validation with the manufacturer |
Mandatory technical note: there is no equivalence table validated by the manufacturer for the Premisut line versus other brands. Consult the technical department of Cahnos before using any substitution in tenders or surgical protocols.
5. Selection tips and variants of interest
Conical point (Taperpoint): choose this configuration for soft, friable or delicate tissues (parenchyma, fat, thin-walled vascular structures); the cylindrical body and conical point minimise tissue trauma. If the tissue presents some fibrosis or resistance (vascular adventitia, fascia), consider the trocar point variant of the same family (ref. AM733HRT3020-2).
USP 2/0 gauge: offers an excellent balance between strength and manageability, widely used in cardiovascular, vascular and soft tissue surgery under moderate tension. For finer tissues, the 3/0 is available on the same needle (733HR3030-2).
Needle length: the 30 mm HR is ideal for deep fields and medium-thickness tissue; for more superficial planes consider the 20 or 25 mm HR from the range, and for bulky tissues the 35 mm HR.
Double needle 2×90 cm: designed for continuous sutures and anastomosis with two armed ends, without re-threading; if you prefer a single 75 cm thread with a single needle, choose the 732HR3020 variant.
Prime range: the Prime line maintains the same needle geometry with a premium finish (improved sharpness and penetration). Always verify the full reference (2xHR30 needle, USP 2/0 gauge and 2×90 cm length) on the packaging, as well as the integrity of the blister and the expiry date before each use. Single-use product, not re-sterilisable.





Reviews