Description
1. Commercial Introduction
The polypropylene suture Premisut Prime P732HR1750 is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, high tensile strength and minimal tissue reaction. This presentation in USP 5/0 gauge incorporates a ½ circle needle with cylindrical body and 17 mm Taperpoint conical point (HR17 Prime profile) and a highly visible 75 cm blue strand: a classic and versatile configuration, highly valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
It is supplied sterile, ready for single use, in a box of 12 units with individual envelopes and batch traceability, which facilitates hospital stock management and presentation to public tenders. Cahnos markets the product keeping the factory reference P732HR1750 (SKU AMP732HR1750) without altering characters: no digit may be added, removed or reordered when ordering or bidding.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer, (C₃H₆)ₙ) extruded as an uncoated monofilament and dyed blue for maximum visibility in the surgical field. Lacking interstices and wicking effect, it offers very smooth passage through tissue, does not favour bacterial adherence or the formation of sinus tracts in wounds at risk of contamination and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR17 needle (½ circle, cylindrical body) with Taperpoint conical point separates and displaces tissue fibres without cutting them, making it ideal for soft, friable tissues and thin-walled vascular structures that require controlled penetration and minimal injury. The Prime finish (fluted-body needle with improved penetration) facilitates grip in the needle holder and smooth, consistent delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Line | Premisut Prime (polypropylene, premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface (knot grip) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| Gauge / USP size | USP 5/0 (metric EP 1.0); conforming to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.100 – 0.149 mm (indicative according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 75 cm (1 thread per sachet) |
| Thread colour | Grooved blue identifier, high visibility in the surgical field |
| Needle shape | ½ circular (1/2 circle), cylindrical body |
| Tip type | Conical Taperpoint, fluted (HR17 profile) |
| Needle size | 17 mm (HR17 Prime profile) |
| Configuration | Single needle (1 × HR17) |
| Manufacturing quality | Prime (premium finish, fluted needle with improved penetration) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Factory reference | P732HR1750 |
| Reference Cahnos (SKU) | AMP732HR1750 |
3.2. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | Metric size | Approximate thread diameter |
| 5/0 | 1.0 | 0.100 – 0.149 mm |
3.3. Family Premisut HR17 Prime (½ circle, cylindrical body, Taperpoint conical point) and range variants
| Profile / Quality | USP size | Presentation | Reference |
| HR17 PRIME (this product) | 5/0 | 1 × 75 cm | P732HR1750 / AMP732HR1750 |
| HR17 PRIME | 4/0 | 1 × 75 cm | P732HR1740 / AMP732HR1740 |
| HR17 PRIME | 3/0 | 1 × 75 cm | P732HR1730 / AMP732HR1730 |
| HR17 (standard) | 5/0 | 1 × 75 cm | 732HR1750 / AM732HR1750 |
| HR17 (standard) | 4/0 | 1 × 75 cm | 732HR1740 / AM732HR1740 |
| HRT 17 PRIME (trocar point) | 5/0 | 1 × 75 cm | P732HRT1750 / AMP732HRT1750 |
4. Equivalences and Cross-References
The reference P732HR1750 corresponds to the official nomenclature of the Premisut Prime range (HR17 profile, single 75 cm thread, USP 5/0 gauge, blue colour). Blue non-absorbable monofilament polypropylene is one of the most standardised permanent suture families on the market (type “Prolene”). There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands; comparisons between brands are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime) | Polypropylene ½ circle HR17 Prime, USP 5/0, blue, 75 cm | P732HR1750 / AMP732HR1750 | Exact reference equivalence (current product) | Official reference of the product analysed in this data sheet |
| Cahnos (Premisut) | Polypropylene ½ circle HR17, USP 5/0, blue, 75 cm (standard) | 732HR1750 / AM732HR1750 | Direct equivalent (same system) | Same HR17 needle, gauge, colour and length; only the premium finish of the needle varies (Prime versus standard) |
| Ethicon (J&J MedTech) | PROLENE® – blue monofilament polypropylene, 5-0, 75 cm (30″), RB-1 ½ circle needle with 17 mm conical point | 8870H (verified in Ethicon product catalogue and authorised distributors) | Functional equivalence by specifications (without official cross-reference table) | Material, gauge, colour, length (75 cm), needle size (17 mm), ½ circle arc and conical point (Taper Point) match. Needle finish and commercial presentation differ (box of 36 units); verify IFU |
| B. Braun (Aesculap) | Premilene® – blue monofilament polypropylene, 5/0 (1), 75 cm, HR17 needle, ½ circle | PREMILENE 5/0 (1) 75CM HR17 CV (GUDID 04046963629564); order code to be confirmed with authorised distribution | Comparable at category level (not interchangeable 1:1) | Material, gauge (EP 1.0), length and 17 mm HR17 needle in ½ circle match. RacePack® presentation and Easyslide needle finish; confirm exact order code and arc in the manufacturer’s technical data sheet |
| B. Braun | Optilene® – polypropylene copolymer with polyethylene, blue, 5/0 (1), 75 cm, HR17 CV needle | C3090012 (verified in official B. Braun catalogue) | Comparable at category level (not interchangeable 1:1) | Gauge, colour, length and HR17 conical point match; but the material is a copolymer (polypropylene + polyethylene), not pure polypropylene, so it is not interchangeable 1:1. Confirm IFU |
| Medtronic (Covidien) | Surgipro™ II – polypropylene copolymer with polyethylene, blue, 5-0, 75 cm (30″), CV-23 ½ circle needle with 17 mm conical point | VP870X (verified in authorised distributors) | Comparable at category level (not interchangeable 1:1) | Same gauge, colour and length; CV-23 needle of 17 mm in ½ circle. Copolymeric material (polypropylene with polyethylene), composition different from the Premisut strand; confirm presentation (single/double needle) and IFU |
Mandatory technical note: before substituting in tender documents, protocol or operating theatre, verify one by one the exact gauge, thread length, needle shape and point (conical vs. trocar), needle size, material (pure polypropylene vs. copolymer) and regulatory classification (CE/MDR) of each manufacturer’s actual product. Consult Cahnos’s technical department before using this information in tendering or direct substitution.
5. Selection tips and variants of interest
- Tissue to suture: the HR17 Prime needle with Taperpoint conical point is indicated for soft, friable tissues and thin-walled vascular structures where the aim is to separate fibres without cutting them (cardiovascular surgery, ophthalmology, neurosurgery). For somewhat more fibrous tissues or vascular adventitia, consider the trocar point (Tapercut) variant of the same family (AMP732HRT1750).
- Gauge: USP 5/0 (metric 1.0) offers the balance between strength and manageability for fine tissues or moderate tension. With the same HR17 Prime needle, the 4/0 (AMP732HR1740) is available for slightly more support and the 3/0 (AMP732HR1730) for greater mechanical strength; in standard quality, the reference AM732HR1750 maintains the same measurements.
- Needle size: the 17 mm HR is ideal for medium-depth surgical fields and delicate tissues, very common in ophthalmology and microsurgery. For smaller fields, it is available with the HR15 (AMP732HR1550) and for deeper approaches, the HR20, HR25 or HR35 needles within the Premisut range.
- Prime range: the Premisut Prime line maintains the same technical configuration with an improved needle finish and superior penetration compared to standard quality; useful when the protocol requires premium quality.
- Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732HR1750 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
- B2B conditions: for hospital supply agreements, volume purchases or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews