Description
1. Commercial Introduction
The polypropylene suture Premisut is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation incorporates a double needle, half circle, conical point (Taperpoint) of 30 mm (profile 2xHR30), USP 3/0 gauge and a blue grooved thread of 90 cm, a configuration especially valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
It is supplied sterile, ready for immediate use, in a box of 12 units with individual sachets and batch traceability. Available at Cahnos with the factory reference 733HR3030-2 (SKU AM733HR3030-2), maintained unchanged.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through the tissue, does not favour bacterial adherence nor the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. As it is non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR30 needle (half circle, cylindrical body) with grooved Taperpoint conical point separates and displaces tissue fibres without cutting them, making it ideal for soft and vascular tissues that require controlled penetration and minimal injury. The double needle format (2x) allows continuous suture techniques and anastomosis with two armed ends without rethreading, optimising surgical time. The highly visible blue thread facilitates identification of the thread and knot on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / line | Premisut (polypropylene, standard range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament (fluted surface for high visibility) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 3/0 (metric EP 2); diameter 0.20 – 0.249 mm; conforming to USP gauges and European Pharmacopoeia. |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Identification blue (fluted) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Conical Taperpoint (grooved), HR profile |
| Needle size | 30 mm (2xHR30) |
| Configuration | Double needle (2 × HR30) |
| Manufacturing quality | Normal (standard) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | 733HR3030-2 |
| Reference Cahnos (SKU) | AM733HR3030-2 |
3.2. Gauge equivalence according to USP/EP standard (non-absorbable suture)
| USP size | Metric size | Approximate thread diameter |
| 3/0 | 2 | 0.20 – 0.249 mm |
3.3. Family Premisut HR 30 (1/2 circle, cylindrical body, conical point) and related variants.
| Needle profile | Presentation | Reference |
| 2xHR30 (standard) | 2 × 90 cm, USP 3/0 (product analysed) | 733HR3030-2 / AM733HR3030-2 |
| 2xHR30 (standard) | 2 × 90 cm, USP 2/0 | 733HR3020-2 / AM733HR3020-2 |
| 2xHR30 Prime | 2 × 90 cm, USP 3/0 | P733HR3030-2 / AMP733HR3030-2 |
| 2xHR30 Prime | 2 × 90 cm, USP 2/0 | P733HR3020-2 / AMP733HR3020-2 |
| 2xHR30 Prime | 2 threads of 90 cm, USP 3/0 (2×90 cm) | P733HR3030.2 / AMP733HR3030.2-2 |
| 2xHR25 (standard) | 2 × 90 cm, USP 3/0 | 733HR2530-2 / AM733HR2530-2 |
| 2xHR20 (standard) | 2 × 90 cm, USP 3/0 | 733HR2030-2 / AM733HR2030-2 |
4. Equivalences and Cross-References
The reference 733HR3030-2 corresponds to the official nomenclature of the Premisut range (profile 2xHR30, double needle conical point, USP 3/0 gauge, blue thread of 90 cm). There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1 without prior technical validation against the technical data sheet and IFU of each manufacturer.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut (Cahnos) | Polypropylene 1/2 circle conical point 2xHR30, USP 3/0, blue, 90 cm | 733HR3030-2 / AM733HR3030-2 | Exact reference equivalence (identical) | Official reference of the analysed product |
| Premisut Prime (Cahnos) | Polypropylene 1/2 circle conical point 2xHR30, USP 3/0, blue, 90 cm | P733HR3030-2 / AMP733HR3030-2 | Direct equivalent (same system) | Same needle geometry, gauge, colour and length; only the premium needle finish varies (Prime version) |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 3/0, 90 cm, double needle SH with half-circle Taperpoint point | 8522H (verified in Ethicon catalogue and authorised distribution; USA presentation 36 units / EMEA 12 units) | Comparable at category level (not interchangeable 1:1) | Matches material, gauge, colour, double needle, half-circle conical point and length (90 cm); SH needle of 26 mm versus HR30 of 30 mm. Confirm IFU and packaging. |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, USP 3/0 (2), 90 cm, double needle HR26 cylindrical/conical point | C2090908 (verified in B. Braun catalogue) | Comparable at category level (not interchangeable 1:1) | Matches material, gauge, colour, double needle and length; HR26 needle of 26 mm versus HR30 of 30 mm and needle finish (Easyslide) to be confirmed in IFU. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene monofilament with polyethylene, blue, USP 3/0, 90 cm, V-20 taper point needle, half circle, 26 mm | VP522X (verified in authorised distribution; box of 36 units) | Comparable by category, not interchangeable 1:1 | Copolymer material (polypropylene with polyethylene, not pure polypropylene); V-20 needle of 26 mm versus HR30 of 30 mm and packaging of 36 units. Verify IFU. |
| DemeTECH | DemeLENE™ – polypropylene, USP 3/0, blue, double needle DSH half circle round body conical point, 90 cm | DT-522-1 (pending confirmation of 1:1 detail in official data sheet) | Comparable by category / pending confirmation | Same gauge, colour and length; DSH needle of 26 mm round body, without grooved channel. Confirm needle size and finish in official catalogue before use. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Premilene®, Surgipro™ II or DemeLENE™ are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Conical point (Taperpoint): choose this configuration for soft, vascular and friable tissues that require penetration without cutting (cardiovascular surgery, ophthalmology, neurosurgery). For tissues with some fibrosis or resistance, consider the trocar point variant (HRT, Tapercut) of the same Premisut family, e.g. AM733HRT3030-2 (USP 3/0, 90 cm).
- USP 3/0 gauge: offers an excellent balance between manageability and strength for vascular ligatures and soft tissue. If greater strength is required, the same 2xHR30 needle is available in USP 2/0 (AM733HR3020-2); for finer tissues, gauges 4/0 and above from the range.
- Needle length: the 30 mm HR is ideal for medium-depth fields. If a shorter needle is required, the 2xHR25 (AM733HR2530-2) or 2xHR20 (AM733HR2030-2) are available in 3/0; for wider planes, the HR 35 from the same family.
- Prime range: the Premisut Prime line (AMP733HR3030-2) maintains the same needle geometry with a premium penetration finish; useful when the protocol requires superior quality in delicate tissues.
- Prior verification: always confirm the full reference (2xHR30 needle, USP 3/0 gauge and 90 cm length) on the packaging; check the integrity of the blister and the expiry date before each use and keep the batch number for traceability in the operating theatre. Single-use product, not re-sterilisable.





Reviews