Description
1. Product Presentation
The PREMISUT polypropylene suture is the reliable choice for approximating and closing soft tissues in demanding procedures. Its uncoated monofilament design, highly visible blue colour and ½ circle needle with a 35 mm conical point offer excellent mechanical performance, smooth tissue passage and minimal inflammatory reaction. This presentation in USP 1 gauge and 75 cm thread is particularly indicated for surgical departments, purchasing centres and tenders that require a non-absorbable thread with predictable and durable behaviour. It is supplied sterile, single-use, in a box of 12 units with batch traceability, facilitating hospital stock management.
2. Technical Explanation
Polypropylene is a linear synthetic polymer (polyolefin) extruded as an uncoated monofilament. Being non-absorbable, the thread is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, making it the classic choice in cardiovascular, vascular, ophthalmic and neurosurgery. Its smooth structure, without interstices or wicking effect, reduces friction, minimises the sawing effect and does not favour bacterial adherence or the formation of sinuses in wounds.
The ½ circle needle with cylindrical body and conical point (taperpoint) of 35 mm (model HR35) penetrates soft tissues and vascular structures with minimal trauma, separating the fibres rather than cutting them, making it especially suitable for delicate tissues, vascular walls and internal structures. The blue colour (phthalocyanine) ensures optimal visibility in the surgical field. Sterilisation by ethylene oxide (EO) ensures the sterility of the single-use device; not re-sterilisable.
3. Technical Specifications
| Characteristic | Specification |
| Brand / Line | PREMISUT (Polypropylene) – standard quality |
| Material | Polypropylene (polypropylene), monofilament, uncoated |
| Absorption | Non-absorbable (gradual encapsulation, no loss of tension) |
| Colour | Blue (high visibility in the surgical field) |
| Gauge | USP 1 (metric EP 4) |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint) |
| Needle size | 35 mm (model HR35) |
| Thread length | 75 cm (1 strand) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Line reference | 732HR3501 |
| Reference Cahnos (SKU) | AM732HR3501 |
Calibre equivalence according to USP/EP standard (non-absorbable suture):
| USP size | Metric size | Approximate thread diameter |
| 1 | 4 | 0.40 – 0.499 mm |
4. Equivalences and Cross-References
There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or substitution. Consult the technical department of Cahnos to validate any equivalence.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (PREMISUT Prime) | Polypropylene HR35, USP 1, blue, 1×75 cm | P732HR3501 / AMP732HR3501 | Direct equivalent within the same family | Same dimensions, gauge, colour and material; needle from the Prime range (PREMILLOY steel, improved penetration) versus standard quality. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 1, CT-1 ½ circle taper point needle | 8425H | Comparable by category (not 1:1) – confirmed code | Same material, USP 1 gauge, 30″ ≈ 75 cm and colour; CT-1 needle of 36 mm (not grooved HR35) versus HR35 of 35 mm. Presentation in box of 36 units. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene with polyethylene, blue monofilament, conical point ½ circle | CP435 (GS-24 needle, 40 mm) | Comparable by category (not 1:1) | Same USP 1 gauge, 30″ ≈ 75 cm and colour; the needle differs (GS-24 of 40 mm versus HR35) and the copolymer composition (adds polyethylene). Verified in catalogues of authorised Medtronic distributors. |
| B. Braun (Aesculap) | Premilene® / Optilene® – blue polypropylene monofilament | C2090153 (Premilene®) / C3090153 (Optilene®) – HR37S needle, 37 mm | Comparable by category (not 1:1) | Same material, USP 1 gauge (EP 4), 75 cm and colour; ½ circle round bodied taper point needle of 37 mm (HR37S) versus HR35 of 35 mm. Codes verified in the official B. Braun catalogue and authorised distributors. |
| Cahnos (PREMISUT) | Polypropylene HR35, USP 0, blue, 75 cm | AM732HR3510 | Comparable within the same family | Same HR35 needle and colour; USP 0 gauge (finer), for thinner tissues. |
| Cahnos (PREMISUT Prime) | Polypropylene HR35 Prime, USP 1, blue, 2×75 cm | P732HR3501.2 / AMP732HR3501.2 | Configuration equivalent within the same system | Same HR35 needle and USP 1 gauge; double thread presentation (2×75 cm) for continuous sutures. |
Mandatory technical note: cross-references with PROLENE®, Surgipro™ II and Premilene®/Optilene® are functional category comparisons; not interchangeable 1:1 without verification of needle geometry, gauge, thread length and presentation.
5. Selection tips and variants of interest
Tissue to suture: the HR needle with conical taperpoint tip is indicated for soft, vascular and slightly distensible planes that require penetration without cutting (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider trocar or triangular tip profiles from the same PREMISUT family.
Needle size: the 35 mm HR is ideal for fields of medium depth. If a shorter needle is required, the HR 30 or HR 25 are available in USP 1 gauge and 75 cm; for wider planes, the HR 40 from the same family.
Gauge: USP 1 offers high tension for vascular ligatures, retention and tissues requiring maximum resistance. If the protocol requires a smaller diameter, the same HR35 family offers USP 0 (ref. AM732HR3510), 2/0 (ref. AM732HR3520) or 3/0 (ref. AM732HR3530).
Presentation: if you need two strands per unit for continuous sutures or anastomosis, consider the double thread version 2×75 cm (ref. AMP732HR3501.2); for greater strand length, the USP 0 version of 90 cm (ref. AM733HR3510).
Prime range: the PREMISUT Prime line maintains the geometry of the standard version with improved needle finish (PREMILLOY steel and superior penetration), useful when the protocol requires premium quality on delicate tissues. Always verify USP gauge, colour, thread length and needle size before placing the order, and keep the reference 732HR3501 and the batch number for traceability in the operating theatre.





Reviews
There are no reviews yet.