Description
1. Presentation
The Premisut Prime VisiBlack polypropylene suture is the reference choice for surgical departments that demand precision, safety and sustained performance in soft tissue approximation. Its design of double needle mounted on a 1/2 circle trajectory, with cylindrical body and conical point (taperpoint) of 25 mm, attached to a 90 cm monofilament thread without fluting dyed blue, make it a versatile solution for both continuous sutures and ligatures in highly demanding procedures.
2. Technical explanation
Monofilament polypropylene is one of the classic non-absorbable suture materials: chemically inert, it generates minimal tissue reaction and offers very smooth passage through tissue thanks to its smooth surface. As it is not absorbed, it gradually encapsulates and maintains optimal tensile strength for more than three months, providing permanent structural support to the sutured plane.
The VisiBlack technology integrates the high-visibility black needle, ideal for surgical fields with high lighting or bleeding, improving contrast during the penetration manoeuvre. The combination of cylindrical body (which slides the thread without cutting) with conical point favours initial penetration in soft tissues reducing tissue trauma. The presentation with double needle (2xHR 25) allows bidirectional continuous sutures without rethreading, optimising surgical times in cardiovascular surgery, ophthalmology, neurosurgery, ligatures and general soft tissue approximation.
3. Technical Specifications
| Parameter | Value |
| Material | Polypropylene monofilament, uncoated |
| Structure | Monofilament, non-fluted thread |
| Absorption | Non-absorbable (gradual encapsulation) |
| Gauge | USP 2/0 (metric 3; approx. diameter 0.30 mm) |
| Thread colour | Blue VisiBlack |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint |
| Needle size | 2xHR 25 mm (double needle) |
| Thread length | 90 cm |
| Sterilisation | Ethylene oxide (EO) |
| Manufacturer reference | P733HR2520-2VB |
| Reference Cahnos (SKU) | AMP733HR2520-2VB |
| Presentation | Box of 12 units |
Gauge variants of the same family (needle 2xHR 25 VisiBlack Prime, thread 90 cm, blue)
| USP size | Colour | Reference Cahnos |
| 3/0 | Blue | AMP733HR2530-2VB |
| 4/0 | Blue | AMP733HR2540-2VB |
| 5/0 | Blue | AMP733HR2550-2VB |
| 2/0 (needle 2xHR 20) | Blue | AMP733HR2020-2 |
4. Equivalences and Cross-References
Methodological note: no published cross-reference table validated by the manufacturer has been found that would allow declaring 1:1 equivalents with other brands. The references indicated below are classified by verified equivalence level and must always be confirmed against the official technical data sheet before substitution in protocol or tender.
| Brand / Line | Reference | Equivalence level | Observations |
| Cahnos – Premisut Prime conical point (without VisiBlack) | AMP733HR2520-2 | Functional category equivalence (not 1:1) | Same gauge 2/0, 90 cm, blue colour and Prime quality; differs in needle technology: standard instead of VisiBlack. |
| Cahnos – Premisut Prime trocar point (tapercut) | AMP733HRT2520-2 | Functional category equivalence (not 1:1) | Same needle 2xHRT 25, gauge 2/0, 90 cm and colour; differs in point type: trocar (tapercut) instead of conical. |
| B.Braun – Optilene (polypropylene-polyethylene, blue) | C3090909 (OPTILENE 2/0 (3) 90CM 2XHR26 CV RCP) | Comparable by category (not 1:1) | Verified in official B.Braun catalogue: gauge USP 2/0 (EP 3), 90 cm, double needle 1/2 circle (2xHR26). Differences: 26 mm needle and copolymer material of polypropylene and polyethylene. |
| Ethicon / Johnson & Johnson MedTech – Prolene (blue monofilament polypropylene) | NW844 (USP 2-0, 1/2 circle round body, 30 mm, 90 cm) | Comparable by category (not 1:1) | Same material, gauge 2-0 and 90 cm, verified in authorised distributors and Ethicon catalogue; differs: single 30 mm needle versus double 25 mm needle. |
Note: there is no equivalence table validated by the manufacturer; consult the technical department of Cahnos before using these references as a direct 1:1 substitute in tenders or surgical protocols.
5. Selection tips and variants of interest
If the protocol does not require VisiBlack needle, the reference AMP733HR2520-2 from the same Prime line offers identical performance with standard needle at a lower cost. For tissues requiring greater initial penetration power, consider the version with trocar point (tapercut) AMP733HRT2520-2.
For finer gauges in ophthalmic or microvascular surgery, we have 3/0 (AMP733HR2530-2VB), 4/0 (AMP733HR2540-2VB) and 5/0 (AMP733HR2550-2VB). For fields requiring larger gauge or shorter needle, request the 2xHR 20 family (e.g. AMP733HR2020-2). There is also the double thread presentation 2×90 cm (AMP733HR2520.2-2) for high-consumption surgeries.
Always verify on the technical data sheet the number of needles (2x), the needle size in mm, the USP gauge and the thread length before formalising the order.