Description
1. Commercial Introduction
The polypropylene suture Premisut Prime VisiBlack that Cahnos makes available to surgical services, purchasing centres and tenders is the reference solution when a non-absorbable thread with predictable behaviour, excellent handling and minimal tissue reaction is required. This presentation incorporates a double ½ circle needle with conical point (taperpoint) of 16 mm in VisiBlack technology (black needle), USP 5/0 gauge and a blue fluted strand of 90 cm: a compact, high-visibility configuration widely used in soft tissue approximation, ligatures and cardiovascular, ophthalmology, vascular and neurosurgery procedures.
It is supplied sterile, ready for single use and with batch traceability, facilitating hospital stock management and presentation to public tenders. It is marketed under the factory reference P733HR1650-2VB (SKU Cahnos AMP733HR1650-2VB), kept without altering characters: no digit may be added, removed or reordered when ordering or bidding. Price per box of 12 units.
2. Technical Explanation
Polypropylene is a linear synthetic polyolefin (propylene polymer) that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The ½ circular needle with conical point (taperpoint) and cylindrical body penetrates soft and lax tissues by separating the fibres without cutting them, making it especially suitable for vascular, cardiovascular tissue and delicate structures. The HR16 profile of 16 mm offers excellent control in reduced, paediatric or deep-access surgical fields. VisiBlack technology incorporates a black needle that dramatically improves its contrast against the surgical field, even in environments with high lighting or bleeding, facilitating visualisation of the tip and the penetration path. The double needle format (2×HR16) allows continuous suture techniques and anastomosis with two armed ends without rethreading, optimising surgical time. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut Prime range (Cahnos S.L.).
| Parameter | Specification |
| Brand / Quality | Premisut Prime (premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament, blue fluted surface for high visibility |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| Gauge / USP size | USP 5/0 (metric 1); diameter 0.10 – 0.149 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Fluted blue (high visibility) |
| Needle shape | ½ circular (1/2 circle), cylindrical body |
| Needle type | Conical point (taperpoint) |
| Needle size | 16 mm (HR16 Prime profile) × 2 needles |
| Configuration | Double needle (2 × HR16) |
| Needle technology | VisiBlack – high-visibility black needle |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single use, sterile. Do not re-sterilise. Do not use if the packaging is open or damaged. |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology, vascular and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Factory reference | P733HR1650-2VB |
| Reference Cahnos (SKU) | AMP733HR1650-2VB |
Gauge equivalence according to USP (indicative):
| USP size | Metric size | Approximate diameter |
| 5/0 | 1 | 0.10 – 0.149 mm (non-absorbable suture) |
4. Equivalences and Cross-References
The reference P733HR1650-2VB corresponds to the official nomenclature of the Premisut Prime range (2×HR16 profile, double 16 mm needle with VisiBlack technology, USP 5/0 gauge and 90 cm blue thread). Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut Prime VisiBlack) | 1/2 circle conical 2×HR16, 5/0, blue, 90 cm (black needle, current product) | P733HR1650-2VB / AMP733HR1650-2VB | Original reference | Analysed product; factory reference without altering characters |
| Cahnos (Premisut Prime) | 1/2 circle conical 2×HR16, 5/0, blue, 90 cm (standard needle) | P733HR1650-2 / AMP733HR1650-2 | Direct range equivalent | Same material, gauge, HR16 needle and length; only the VisiBlack finish (black needle) of this reference varies |
| Cahnos (Premisut Prime VisiBlack) | 1/2 circle conical 2×HR20, 5/0, blue, 90 cm (black needle) | P733HR2050-2VB / AMP733HR2050-2VB | Direct range equivalent | Same material, gauge, colour and length; HR20 needle of 20 mm versus HR16 of 16 mm |
| Cahnos (Premisut Prime VisiBlack) | 1/2 circle conical 2×HR25, 5/0, blue, 90 cm (black needle) | P733HR2550-2VB / AMP733HR2550-2VB | Direct range equivalent | Same material, gauge, colour and length; HR25 needle of 25 mm for deeper planes |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® – blue polypropylene monofilament, 5/0, 90 cm, double RB-1 taperpoint needle of 17 mm | 8556G (box of 12 units) / 8556H (box of 36 units) | Comparable by category, not interchangeable 1:1 | Code verified in Ethicon catalogue and authorised distribution: material, gauge, colour, length and double conical-point needle match; the RB-1 needle of 17 mm differs from HR16 of 16 mm |
| Ethicon (Johnson & Johnson MedTech) | PROLENE® with VISI-BLACK® needle – 5/0, 90 cm, double RB-1 needle of 17 mm (black needle) | 8356H | Comparable by category, not interchangeable 1:1 | Code verified in the Ethicon product centre: high-visibility black needle of 17 mm (1/2 circle, conical point) compared to HR16 of 16 mm; same blue polypropylene base |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 5/0 (EP 1), 90 cm, double needle 2×HR26 | C2090905 | Comparable by category, not interchangeable 1:1 | Verified in B. Braun catalogue and device data sheet (AccessGUDID): same material, gauge, colour and double conical needle; HR26 needle of 26 mm compared to HR16 of 16 mm; RacePack packaging |
| B. Braun (Aesculap) | Optilene® – polypropylene-polyethylene copolymer, blue, 5/0 (EP 1), 90 cm, double needle 2×HR26 CV RCP | C3090905 | Comparable by category, not interchangeable 1:1 | Verified in official B. Braun catalogue: same gauge and double needle configuration; differs in material (polypropylene and polyethylene copolymer compared to pure polypropylene) and the 26 mm needle |
| Medtronic (Covidien) / Serag-Wiessner / DemeTECH | Surgipro™ II / SERAPREN® / DemeLENE™ – blue polypropylene | Pending confirmation for 5/0, 90 cm, 2×HR16 | Comparable by category, not verified | Polypropylene families with similar clinical indication; confirm material (copolymer compared to pure polypropylene), geometry and needle size in official catalogue before substituting |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references the reference P733HR1650-2VB with other brands; comparisons with PROLENE®, Premilene® or Optilene® are functional, at category level, and must be validated against the technical data sheet or the IFU of each manufacturer before use in tendering or direct substitution. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
- Tissue to suture: the conical point needle (taperpoint) with cylindrical body is the choice for soft, lax and vascular tissues, as it separates the fibres without cutting them (optimal in cardiovascular and vascular surgery). If the protocol requires crossing more fibrous tissues or calcified adventitia, consider the trocar point (tapercut) variant from the same range.
- Needle size: the HR16 of 16 mm is indicated for reduced, paediatric or deep-access surgical fields, with excellent tip control. If you need greater reach in medium-depth planes, you have the HR20 (AMP733HR2050-2VB) or HR25 (AMP733HR2550-2VB) from the same VisiBlack family in 5/0.
- Double needle format: the 2×HR16 presentation allows continuous suture and anastomosis techniques with two armed ends without rethreading, optimising surgical time and material consumption.
- Gauge: the USP 5/0 (metric 1) is very fine and highly manageable, ideal for ophthalmology, microvascular and delicate soft tissue. For greater mechanical demands, the same VisiBlack family is available in USP 4/0 (AMP733HR1640-2VB), 3/0 (AMP733HR2530-2VB) and 2/0 (AMP733HR2520-2VB).
- VisiBlack technology: the black needle of this reference offers superior contrast on the surgical field, reducing needle localisation time and improving precision in deep planes or under intense lighting; it is the recommended choice when needle visibility is critical.
- Verification and storage: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P733HR1650-2VB and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews