Description
1. Commercial Introduction
The polypropylene suture PREMISUT PRIME is the reference choice for surgical departments, purchasing centres and tenders that require a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that penetrates tissue with full control. This presentation in USP 3/0 gauge mounts a ½ circle needle with cylindrical body and grooved Taperpoint conical point of 35 mm (HR 35 Prime profile) and a highly visible blue thread of 75 cm, designed for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
It is supplied sterile and ready for individual use in a box of 12 units with batch traceability, facilitating hospital stock management and presentation for public tenders. Available under the factory reference P732HR3530 (SKU Cahnos AMP732HR3530), kept without altering characters: no digit may be added, removed or reordered when ordering or bidding.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) presented as an uncoated monofilament, dyed blue. Lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The HR 35 Prime needle (½ circle, cylindrical body and grooved Taperpoint conical point of 35 mm) penetrates soft tissues by separating and displacing fibres without cutting them, making it ideal for vascular tissue and delicate structures. The grooved finish of the needle body and the Prime range steel improve grip in the needle holder and facilitate smooth and consistent delivery during knotting. The blue colour ensures optimal visibility over the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the Premisut range (Cahnos S.L.).
| Parameter | Specification |
| Brand / Line | Premisut Prime – polypropylene (premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| Gauge / USP size | USP 3/0 (EP metric 2); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.200 – 0.249 mm (indicative, according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 75 cm (1 thread per unit) |
| Thread colour | High-visibility blue |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Cylindrical body with tapered Taperpoint point, ribbed (HR 35 Prime profile) |
| Needle size | 35 mm |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P732HR3530 |
| Reference Cahnos (SKU) | AMP732HR3530 |
Gauge equivalence according to USP (indicative):
| USP size | Metric size | Approximate thread diameter |
| 3/0 | 2 | 0.200 – 0.249 mm (non-absorbable suture) |
Variants of the Premisut Prime HR 35 family (blue thread):
| Needle profile | USP size | Presentation | Reference |
| HR 35 Prime | 3/0 | 1 × 75 cm | AMP732HR3530 (this product) |
| HR 35 Prime | 3/0 | 2 × 75 cm | AMP732HR3530.2 |
| HR 35 Prime | 3/0 | 1 × 90 cm | AMP733HR3530 |
| HR 35 Prime | 2/0 | 1 × 75 cm | AMP732HR3520 |
| HR 35 Prime | 0 | 1 × 75 cm | AMP732HR3510 |
| HR 35 Prime | 1 | 1 × 75 cm | AMP732HR3501 |
4. Equivalences and Cross-References
The reference P732HR3530 corresponds to the official nomenclature of the Premisut Prime range (HR 35 Prime profile, single needle, USP 3/0 gauge, blue thread of 75 cm) and Cahnos markets it without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos – Premisut Prime | Polypropylene HR 35 Prime, USP 3/0, blue, 1 × 90 cm | P733HR3530 / AMP733HR3530 | Configuration equivalent within the same system | Same HR 35 ribbed needle and gauge; thread of 90 cm instead of 75 cm |
| Cahnos – Premisut Prime | Polypropylene HR 35 Prime, USP 3/0, blue, 2 × 75 cm | P732HR3530.2 / AMP732HR3530.2 | Configuration equivalent within the same system | Same needle and gauge; double thread 2 × 75 cm |
| Cahnos – Premisut | Polypropylene HR 35, USP 3/0, blue, 1 × 75 cm (standard) | 732HR3530 / AM732HR3530 | Direct equivalent within the same family (not Prime) | Same measurements and material; standard quality needle versus the Prime range |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 3/0, 75 cm, SH taper needle ½ circle | 8832T | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution: same material, gauge, colour and length; SH needle of 26 mm versus HR 35 of 35 mm; packaging of 24 units. Confirm CE/MDR traceability against IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, USP 3/0, 75 cm, HR26 needle with round body ½ circle | C2090041 | Comparable by category, not interchangeable 1:1 | Code verified in distribution sources: same material, gauge and length; HR26 needle of 26 mm and non-grooved finish versus grooved HR 35 of 35 mm. Confirm geometry in official catalogue |
| Medtronic (Covidien) | Surgipro™ II – polypropylene/polyethylene copolymer, blue, USP 3/0, 75 cm, GS-21 taper point needle of ½ circle | CP-422 | Comparable by category, not interchangeable 1:1 | Code verified in authorised distribution: same gauge, colour and length; copolymeric material (not pure polypropylene) and GS-21 needle of 37 mm versus HR 35 of 35 mm; packaging of 36 units |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the previous comparisons are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tendering or direct substitution. Consult the technical department of Cahnos to validate any equivalence before use.
5. Selection tips and variants of interest
- Tissue to suture: the HR needle with grooved Taperpoint conical point is indicated for soft, vascular and low-distensibility flat tissues that require penetration without cutting (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider trocar point profiles (HRT) or triangular from the same Premisut Prime range.
- Needle size: the HR of 35 mm offers an excellent balance between control and penetration in medium-depth fields. If a shorter needle is required, the HR 30 (ref. AMP732HR3030 in 3/0 and 75 cm) or HR 25 (ref. AMP732HR2530) is available; for wider planes, the HR 40 from the same family.
- Gauge: USP 3/0 (metric 2) is very versatile for soft, vascular and cardiovascular tissue. For greater mechanical demand, the same HR 35 Prime family is available in USP 2/0 (ref. AMP732HR3520) or USP 0 (ref. AMP732HR3510) and, for delicate tissues or microsurgery, gauges 4/0, 5/0 and 6/0 within the Premisut Prime catalogue.
- Presentation: the single thread version of this data sheet is the most economical option per unit for occasional uses; if the protocol requires double strand, the 2 × 75 cm version (ref. AMP732HR3530.2) optimises utilisation per procedure and reduces the opening of packaging for continuous sutures and anastomoses.
- Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732HR3530 and the batch number for traceability in the operating theatre and in case of complaint.
- B2B conditions: for hospital supply agreements, public tenders or equivalences from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews