Description
1. Commercial Introduction
The polypropylene suture Premisut Prime is the reference choice for operating theatres, purchasing departments and tenders that need a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that penetrates tissue with total control. This presentation in calibre USP 0, with a ½ circle needle with a ribbed conical point of 35 mm (HR 35 Prime profile) and a blue thread of 90 cm, is especially indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
It is supplied sterile and ready for individual use in a box of 12 units with batch traceability, facilitating the management of hospital stocks and presentation to public tenders. Factory reference P733HR3510, marketed by Cahnos as SKU AMP733HR3510, maintaining the manufacturer’s official nomenclature without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin that is presented as an uncoated monofilament, dyed blue with phthalocyanine. As it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period and is gradually encapsulated by connective tissue, helping the wound for more than three months, in accordance with USP and European Pharmacopoeia calibres.
The HR 35 Prime needle (½ circle, cylindrical body and ribbed taperpoint conical point of 35 mm, in PREMILLOY steel) separates and displaces tissue fibres without cutting them, making it ideal for soft and vascular tissues that require controlled penetration and minimal injury. The ribbed finish of the needle body facilitates smooth delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
| Brand / Line | Premisut – Prime quality |
| Thread material | Polypropylene monofilament, uncoated, dyed blue (synthetic linear polyolefin) |
| Thread structure | Monofilament with ribbed needle (RHR 35 Prime profile) |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 90 cm (1 thread) |
| Thread colour | Blue (phthalocyanine), high visibility in the surgical field |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Taperpoint conical point (cylindrical body), ribbed (HR 35 profile) |
| Needle size | 35 mm (HR 35 Prime profile / RHR 35 ribbed prime) |
| Needle steel | PREMILLOY (Prime range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P733HR3510 |
| Reference Cahnos (SKU) | AMP733HR3510 |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
Calibre equivalence according to USP/EP standard (non-absorbable suture):
| USP size | Metric size | Approximate thread diameter |
| 0 | 3.5 | 0.35 – 0.399 mm |
4. Equivalences and Cross-References
The reference P733HR3510 corresponds to the official nomenclature of the Premisut Prime range (ribbed HR 35 Prime profile, 90 cm thread, USP 0 calibre, blue colour) and Cahnos markets it without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos (Premisut) | Polypropylene HR 35, USP 0, blue, 1×90 cm (standard) | 733HR3510 / AM733HR3510 | Direct equivalent within the same family | Same measurements and material; standard quality needle compared to the Prime range (improved steel and penetration) |
| Cahnos (Premisut Prime) | Polypropylene HR 35 Prime, USP 0, blue, 2×90 cm | P733HR3510.2 / AMP733HR3510.2 | Configuration equivalent within the same system | Same ribbed HR 35 needle and USP 0 calibre; the presentation changes to double thread (2×90 cm) |
| Cahnos (Premisut Prime) | Polypropylene HR 35 Prime, USP 0, blue, 1×75 cm | P732HR3510 / AMP732HR3510 | Configuration equivalent within the same system | Same ribbed HR 35 needle and calibre; 75 cm thread instead of 90 cm |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 0, 90 cm, RB needle of 30 mm | NW846 | Comparable by category (not interchangeable 1:1) | Material, calibre, colour and length (90 cm) match; the RB needle is 30 mm and not ribbed compared to the ribbed HR 35 of 35 mm. Verified in official Ethicon catalogue |
| Medtronic (Covidien) | Surgipro™ II – polypropylene with polyethylene, blue monofilament, conical point ½ circle | CP-424 (USP 0, blue, 30″ ≈ 76 cm, GS-21 needle of 37 mm) | Comparable by category (not interchangeable 1:1) | Same calibre and conical point; copolymeric material (adds polyethylene) and different lengths; verify in official Medtronic catalogue |
| B. Braun | Premilene® / Dafilon® – blue polypropylene monofilament | Series C2090 (pending confirmation) | Pending confirmation | Sector family with same clinical indication; confirm needle geometry and length in official B. Braun catalogue |
| Assut Europe | Assupro® – blue polypropylene monofilament | Consult official catalogue | Pending confirmation | Same clinical indication; not interchangeable 1:1 without technical verification |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Surgipro™ II, Premilene®/Dafilon® or Assupro® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
Tissue to suture: the HR needle with ribbed Taperpoint conical point is indicated for soft, vascular and poorly distensible flat tissues that require penetration without cutting (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider trocar point profiles (HRT) or triangular profiles from the same Premisut Prime range.
Needle size: the 35 mm HR is ideal for medium-depth fields. If you need a shorter needle, the HR 30 (ref. AMP733HR3010) or HR 25 (ref. AMP733HR2510) is available; for wider planes, the HR 40 from the same family.
Gauge: USP 0 offers a very balanced medium-high tension for vascular ligatures and soft tissues. If the protocol requires a smaller diameter, the same HR 35 Prime family offers USP 2/0 (ref. AMP733HR3520) or USP 3/0 (ref. AMP733HR3530); for greater strength, USP 1 (ref. AMP733HR3501).
Presentation: the double-thread version 2×90 cm (ref. AMP733HR3510.2) optimises usage per procedure; the standard alternative without the Prime range (AM733HR3510) maintains the same measurements with a conventional-quality needle.
Prime range: the Premisut Prime line maintains the geometry of the standard version with an improved needle finish (superior penetration and PREMILLOY steel), useful when the protocol requires premium quality on delicate tissues. Always verify USP gauge, colour, thread length and needle size before placing the order; keep the reference P733HR3510 and the batch number for traceability in the operating theatre. Product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use. For special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews