Description
1. Commercial Introduction
The polypropylene suture Premisut Prime P732HR1740 is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, maximum tensile strength and minimal tissue reaction. This presentation in USP 4/0 gauge incorporates a ½ circle needle with a cylindrical body and Taperpoint conical point of 17 mm (HR17 Prime profile) and a 75 cm grooved blue strand: a classic and versatile configuration, highly valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
It is supplied sterile, ready for single use, in a box of 12 units with individual sachets and batch traceability. Cahnos markets it keeping the factory reference P732HR1740 (SKU AMP732HR1740) without altering characters: no digit may be added, removed or reordered when ordering or tendering.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer, (C₃H₆)ₙ) extruded as uncoated monofilament and dyed blue for maximum visibility in the surgical field. Lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it becomes gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR17 needle (½ circle, cylindrical body) with Taperpoint conical point separates and displaces tissue fibres without cutting them, making it ideal for soft, friable tissues and thin-walled vascular structures requiring controlled penetration and minimal injury. The Prime finish (grooved-body needle with improved penetration) facilitates grip in the needle holder and smooth, consistent delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / Line | Premisut Prime (polypropylene, premium range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface (knot grip) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| Gauge / USP size | USP 4/0 (metric EP 1.5); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.15 – 0.199 mm (indicative according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 75 cm (1 thread per sachet) |
| Thread colour | Grooved blue identifier, high visibility in the surgical field |
| Needle shape | ½ circular (1/2 circle), cylindrical body |
| Tip type | Conical Taperpoint, fluted (HR17 profile) |
| Needle size | 17 mm (HR17 Prime profile) |
| Configuration | Single needle (1 × HR17) |
| Manufacturing quality | Prime (premium finish, fluted needle with improved penetration) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Factory reference | P732HR1740 |
| Reference Cahnos (SKU) | AMP732HR1740 |
3.2. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | Metric size | Approximate thread diameter |
|---|---|---|
| 4/0 | 1.5 | 0.15 – 0.199 mm |
3.3. Family Premisut HR17 Prime (½ circle, cylindrical body, Taperpoint conical point) and range variants
| Profile / Quality | USP size | Presentation | Reference Cahnos |
|---|---|---|---|
| HR17 PRIME (this product) | 4/0 | 1 × 75 cm | P732HR1740 / AMP732HR1740 |
| HR17 PRIME | 3/0 | 1 × 75 cm | P732HR1730 / AMP732HR1730 |
| HR17 PRIME | 5/0 | 1 × 75 cm | P732HR1750 / AMP732HR1750 |
| HR17 (standard) | 4/0 | 1 × 75 cm | 732HR1740 / AM732HR1740 |
| HR17 (standard) | 3/0 | 1 × 75 cm | 732HR1730 / AM732HR1730 |
| HRT 17 PRIME (trocar point) | 4/0 | 1 × 75 cm | P732HRT1740 / AMP732HRT1740 |
4. Equivalences and Cross-References
The reference P732HR1740 corresponds to the official nomenclature of the Premisut Prime range (HR17 profile, single 75 cm thread, USP 4/0 gauge, blue colour). Blue non-absorbable polypropylene monofilament is one of the most standardised permanent suture families on the market (type ‘Prolene’). There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands; comparisons between brands are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or the IFU of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene ½ circle HR17 Prime, USP 4/0, blue, 75 cm | P732HR1740 / AMP732HR1740 | Exact reference equivalence (current product) | Official reference of the product analysed in this data sheet |
| Cahnos (Premisut) | Polypropylene ½ circle HR17, USP 4/0, blue, 75 cm (standard) | 732HR1740 / AM732HR1740 | Direct equivalent (same system) | Same HR17 needle, gauge, colour and length; only the premium finish of the needle varies (Prime versus standard) |
| Cahnos (Premisut) | Polypropylene ½ circle HRT 17, USP 4/0, blue, 75 cm – trocar point | 732HRT1740 / AM732HRT1740 | Comparable by category (not interchangeable 1:1) | Same gauge, colour, length and 17 mm needle; the point differs: trocar (Tapercut) versus conical (Taperpoint). Different penetration profile for fibrous tissue |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 4-0, 75 cm, RB-1 needle of 17 mm, ½ circle, conical point | 8871H (verified at authorised distributors) | Comparable at category level (not interchangeable 1:1) | Material, gauge, colour, length (75 cm), needle size (17 mm), ½ circle arc and conical point (Taper Point) match. Needle finish and commercial presentation differ (box of 36 units); verify IFU |
| B. Braun (Aesculap) | Premilene® – blue polypropylene, 4/0 (1.5), 75 cm, HRT 17 needle, ½ circle, trocar point | C2090315 (GUDID GTIN 04046963632243; PREMILENE 4/0 (1.5) 75CM HRT17 (M)) | Comparable at category level (not interchangeable 1:1) | Material, gauge (EP 1.5), 75 cm length and 17 mm needle in ½ circle match; the point differs (trocar versus conical) and the commercial presentation. Verify IFU |
| B. Braun | Optilene® – copolymer of polypropylene with polyethylene, blue, 4/0 (1.5), 75 cm, HR17 needle conical point | C3090013 (verified in B. Braun catalogue) | Comparable at category level (not interchangeable 1:1) | Gauge, colour, length and conical point match; but the material is a copolymer (not pure polypropylene), so it is not interchangeable 1:1. Confirm IFU |
| Medtronic (Covidien) | Surgipro™ II – copolymer of polypropylene with polyethylene, blue, 4-0, 75 cm, CV-23 needle, ½ circle, conical point | VP-871-X (verified at authorised distributors) | Comparable at category level (not interchangeable 1:1) | Same gauge, colour and length; CV-23 needle with conical point. Copolymer material (polypropylene with polyethylene), composition different from the Premisut strand |
Mandatory technical note: before substituting in a specification, protocol or operating theatre, verify one by one the exact gauge, thread length, needle shape and point (conical vs. trocar), needle size, material (pure polypropylene vs. copolymer) and regulatory classification (CE/MDR) of each manufacturer’s actual product. Consult the technical department of Cahnos before using this information in tendering or direct substitution.
5. Selection tips and variants of interest
Tissue to suture: the HR17 Prime needle with Taperpoint conical point is indicated for soft, friable tissues and thin-walled vascular structures where the aim is to separate fibres without cutting them (cardiovascular surgery, ophthalmology, neurosurgery). For somewhat more fibrous tissues or vascular adventitia, consider the trocar point (Tapercut) variant of the same family (AM732HRT1740).
Gauge: USP 4/0 (metric 1.5) offers an excellent balance between strength and handling for soft tissues of medium tension and ligatures. With the same HR17 Prime needle, the 3/0 (AMP732HR1730) is available for greater strength and the 5/0 (AMP732HR1750) for finer tissues; in standard quality, references AM732HR1730, AM732HR1740 and AM732HR1750.
Needle size: the 17 mm HR is ideal for surgical fields of medium depth and delicate tissues, very common in ophthalmology and microsurgery. For smaller fields, the HR15 (AM732HR1540) is available, and for deeper approaches, the HR20 (AM732HR2040), HR25 (AM732HR2540) or HR35 needles within the Premisut range.
Prime range: the Premisut Prime line maintains the same technical configuration with improved needle finish and superior penetration compared with standard quality; useful when the protocol demands premium quality. If you prefer a double armed needle, please refer to the 2×90 cm series (series 733) from the same family.
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P732HR1740 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews