Description
1. Product Presentation
The PREMISUT PRIME polypropylene suture is the reference choice in the operating theatre when a high-performance non-absorbable suture is required: maximum knot security, minimal tissue reaction and a superior precision needle. This presentation with a ½ circle 35 mm needle in ribbed conical point (taperpoint) and two 75 cm threads in USP 1 gauge is designed for cardiovascular surgery, ophthalmology and neurosurgery procedures where each stitch must offer predictable and durable behaviour. It is supplied in a box of 12 sterile units, ready for immediate use.
2. Technical Explanation
The thread is made of uncoated polypropylene monofilament, a synthetic, biologically inert linear polyolefin that is neither absorbed nor degraded by tissue enzymes: it maintains its tensile strength permanently and exceeds the requirements of the USP and EP pharmacopoeias. Its smooth, interstice-free monofilament structure minimises the sawing effect and reduces the risk of infection or sinus formation in wounds. It causes minimal initial inflammation, followed by gradual encapsulation by fibrous connective tissue that preserves structural integrity for more than three months.
The ½ circle ribbed conical point (taperpoint) needle of 35 mm from the Prime range, manufactured in PREMILLOY steel, penetrates by separating tissue fibres without cutting them; the grooves on the point facilitate initial grip and controlled passage, making it ideal for soft tissues, ligatures and anastomoses. The blue colour (phthalocyanine) guarantees excellent visibility on the surgical field. Ethylene oxide sterilisation ensures the sterility of the single-use device.
3. Technical Specifications
| Parameter | Specification |
| Brand / Line | Premisut Prime (Polypropylene) |
| Material | Polypropylene (polypropylene), monofilament, uncoated |
| Structure | Monofilament |
| Absorption | Non-absorbable; gradual encapsulation, maintains tensile strength for more than three months |
| Thread colour | Ribbed blue (phthalocyanine), high visibility |
| Gauge | USP 1 (metric 4) |
| Needle shape | ½ circle, cylindrical body |
| Needle tip | Taperpoint |
| Needle size | 35 mm (model HR35 / RHR 35 Ribbed Prime) |
| Needle steel | PREMILLOY (Prime range) |
| Thread length | 2 strands of 75 cm (2×75 cm) |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 12 sterile single-use units |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Line reference | P732HR3501.2 |
| Reference Cahnos (SKU) | AMP732HR3501.2 |
4. Equivalences and Cross-References
There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; the following comparisons have been verified against official catalogues and authorised distributors and are functional category comparisons, not 1:1 interchangeable. Always verify needle geometry and size, gauge, length and thread presentation before substituting.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, ½ circle conical point needle CT-1 | 8425H | Comparable by category (not 1:1) | Same USP 1 gauge and 75 cm thread, but CT-1 taper point needle of 36 mm (not ribbed HR35) and presentation of 1 thread versus 2×75 cm. Code confirmed in catalogues of authorised Ethicon distributors. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, ½ circle non-cutting curved needle 35 mm | A-8425 | Comparable by category (not 1:1) – pending confirmation | Same USP 1 gauge, 35 mm needle and 75 cm thread, but not ribbed and presentation of 1 thread. Code located at distributor; confirm with official Ethicon catalogue before use in tenders. |
| Medtronic (Covidien) | Surgipro™ II – blue polypropylene monofilament, taper point ½ circle | GS / VP series (exact code pending confirmation) | Comparable by category (not 1:1) | Same clinical indication and USP 1 gauge, but taper point needle of another size and presentation of 1 thread; no specific code with USP 1 + 35 mm + 2×75 cm was found in the public official catalogue. |
| B. Braun | Premilene® / Optilene® – blue polypropylene monofilament | C3090xxx series (pending confirmation) | Comparable by category (not 1:1) | Same indication and material; C series codes in 75 cm with HRC/DR needles, without exact match with HR35 ribbed taperpoint USP 1 in the official catalogue consulted. Verify with manufacturer. |
| DemeTECH | DemeLENE® – blue polypropylene monofilament, round body ½ circle | Consult official catalogue (pending confirmation) | Comparable by category (not 1:1) | Same clinical indication and material; round body needle and different sizes. Not 1:1 interchangeable without technical verification. |
Important: there is no manufacturer-validated equivalence table Premisut for this reference; consult our technical department before using these cross-references in tenders or closed surgical protocols.
5. Selection tips and variants of interest
Before substituting this suture always verify: needle geometry and size (HR35 ribbed taperpoint), USP gauge, thread length and presentation (2 threads versus 1 thread). This variant in 2×75 cm and USP 1 is ideal for continuous sutures and cardiovascular surgery procedures and ligatures where two strands per unit are required. In the same HR35 Prime family, the following alternatives are available in the catalogue:
- USP 1, 1 thread of 75 cm (ref. AMP732HR3501) for single-thread interrupted sutures.
- USP 0, 2×75 cm (ref. AMP732HR3510.2) and USP 2/0, 2×75 cm (ref. AMP732HR3520.2) for thinner tissues.
- USP 0, 2×90 cm (ref. AMP733HR3510.2) when a longer strand length is needed.
If the protocol requires a trocar point for dense or fibrous tissues, consider the HRT range; for microsurgery and fine gauges, the Prime family offers needles from 13 mm to 20 mm with double needle. The Prime line provides a PREMILLOY steel needle with improved penetration compared to standard Premisut quality, maintaining identical mechanical performance of the thread.





Reviews