Description
1. Commercial Introduction
The polypropylene suture PREMISUT is the reference choice for surgical departments, purchasing centres and tenders that require a non-absorbable thread with predictable behaviour, high tensile strength and minimal tissue reaction. This presentation incorporates a double ½ circle taper point needle of 20 mm (profile 2×HR20), USP 3/0 gauge and a 90 cm blue fluted strand, a configuration especially valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
It is supplied sterile and ready for individual use, in a box of 12 units with individual sachets and batch traceability, which facilitates hospital stock management and presentation to public tenders. Available at Cahnos with factory reference 733HR2030-2 (SKU AM733HR2030-2), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) that is presented as an uncoated monofilament dyed blue: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. As it is non-absorbable, it is not degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR needle (½ circle, cylindrical body) with Taperpoint conical point passes through soft and friable tissues by separating the fibres without cutting them, minimising trauma to the suture bed: it is the ideal geometry for parenchyma, fatty tissue and thin-walled vascular structures. The 20 mm HR20 profile offers excellent control in superficial and medium-thickness surgical fields. The double needle format (2×) allows continuous suture techniques and anastomosis with two armed ends without rethreading, optimising surgical time. The highly visible fluted blue strand facilitates identification of the thread and knot on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / line | PREMISUT (polypropylene, standard range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with highly visible fluted surface |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 3/0 (EP metric 2); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.20 – 0.249 mm |
| Thread length | 90 cm (1 thread per unit, double-armed) |
| Thread colour | Identification blue (fluted) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Taperpoint conical, HR profile |
| Needle size | 20 mm (2 × HR20, double needle) |
| Configuration | Double needle (2 × HR20) |
| Manufacturing quality | Normal (standard) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 733HR2030-2 |
| Reference Cahnos (SKU) | AM733HR2030-2 |
3.2. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | Metric size | Approximate thread diameter |
|---|---|---|
| 3/0 | 2 | 0.20 – 0.249 mm |
3.3. PREMISUT family 2×HR20 (½ circle, cylindrical body, taper point) and range variants
| Needle profile | Presentation | Reference |
|---|---|---|
| 2×HR20 (standard) | 2 × 90 cm, USP 3/0 (product analysed) | 733HR2030-2 / AM733HR2030-2 |
| 2×HR20 Prime | 2 × 90 cm, USP 3/0, premium finish | P733HR2030-2 / AMP733HR2030-2 |
| 2×HR20 (standard) | 2 × 90 cm, USP 2/0 | 733HR2020-2 / AM733HR2020-2 |
| 2×HR20 Prime | 2 × 90 cm, USP 4/0 | P733HR2040-2 / AMP733HR2040-2 |
| HR20 (standard, single needle) | 1 × 75 cm, USP 3/0 | 732HR2030 / AM732HR2030 |
| 2×HR25 (standard) | 2 × 90 cm, USP 3/0 | 733HR2530-2 / AM733HR2530-2 |
| 2×HR30 (standard) | 2 × 90 cm, USP 3/0 | 733HR3030-2 / AM733HR3030-2 |
4. Equivalences and Cross-References
Reference 733HR2030-2 corresponds to the official nomenclature of the PREMISUT range (profile 2×HR20, double taper point needle, USP 3/0 gauge, blue 90 cm thread). There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons between brands are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (PREMISUT Prime) | Polypropylene 1/2 circle 2×HR20, USP 3/0, blue, 90 cm | P733HR2030-2 / AMP733HR2030-2 | Direct equivalent (same system) | Same needle geometry, gauge, colour and length; the premium finish of the needle varies (Prime version) |
| Cahnos (PREMISUT) | Polypropylene 1/2 circle 2×HR20, USP 2/0, blue, 90 cm | 733HR2020-2 / AM733HR2020-2 | Configuration equivalent (same system) | Same needle 2×HR20 and length; gauge changes to USP 2/0 |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 3/0, 90 cm, double SH ½ circle taper point needle of 26 mm | 8522H | Comparable by category (not interchangeable 1:1) | Matches material, gauge, colour, double needle and length; SH needle of 26 mm versus HR20 of 20 mm; usual box of 36 units. Verified in official Ethicon catalogue and authorised distribution. |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, USP 3/0 (metric 2), 90 cm, double 2×HR26 CV taper point needle | C2090908 | Comparable by category (not interchangeable 1:1) | Matches material, gauge, colour, double needle and length; HR26 needle of 26 mm versus HR20 of 20 mm; RacePack packaging. Verified in B. Braun catalogue. |
| B. Braun (Aesculap) | Optilene® – polypropylene-polyethylene copolymer, blue, USP 3/0, 90 cm, double HR26 taper point needle | C3090908 | Comparable by category (not interchangeable 1:1) | Copolymeric composition (PP/PE) versus pure polypropylene; HR26 needle of 26 mm. Verified in official B. Braun catalogue. |
| DemeTECH | DemeLENE™ – polypropylene, USP 3/0, blue, double DSH ½ circle round body needle, 90 cm | DT-522-1 | Comparable by category (not interchangeable 1:1) | Same gauge, colour and length; DSH needle of 26 mm round body without fluted surface. Verified in official DemeTECH store. |
| Medtronic (Covidien) | Surgipro™ II – polypropylene monofilament with polyethylene, blue, USP 3/0, 90 cm, V-20 taper point ½ circle needle of 26 mm | VP522X | Comparable by category (not interchangeable 1:1) | Copolymeric material (not pure polypropylene); V-20 needle of 26 mm versus HR20 of 20 mm; pack of 36 units. Verified in authorised distribution. |
Mandatory technical note: there is no equivalence table validated by the manufacturer for the PREMISUT line versus other brands. Before substituting in tender documents, protocols or operating theatre, verify one by one the exact gauge, thread length, needle shape and point (taper point versus cutting), needle size, material (pure polypropylene versus copolymer) and regulatory classification (CE/MDR) of the actual product from each manufacturer. Consult the technical department of Cahnos before using any substitution in tenders or surgical protocols.
5. Selection tips and variants of interest
Taper point (Taperpoint): choose this configuration for soft, friable or delicate tissues (parenchyma, fat, thin-walled vascular structures); the cylindrical body and taper point minimise tissue trauma. For tissues with some fibrosis or resistance (vascular adventitia, fascia), consider the tapercut point variant (Tapercut) of the same family (e.g. AM733HRT2030-2, USP 3/0, 90 cm).
USP gauge 3/0 (metric EP 2): offers an excellent balance between strength and manageability, widely used in cardiovascular, vascular, ophthalmology and soft tissue surgery. For finer tissues, the same 2×HR20 needle is available in gauges 4/0 (AMP733HR2040-2) and 5/0 (AMP733HR2050-2); for greater strength, in USP 2/0 (AM733HR2020-2).
Needle length: the 20 mm HR is ideal for superficial and medium-thickness surgical fields, very common in ophthalmology and vascular microsurgery. If you need greater reach in deeper planes, consider the 25 mm HR (AM733HR2530-2) or the 30 mm HR (AM733HR3030-2) from the same standard range, in USP gauge 3/0.
Double needle format 2×90 cm: designed for continuous suture and anastomosis techniques with two armed ends, without rethreading, optimising surgical time. If you prefer a single 75 cm thread with a single needle, choose the AM732HR2030 variant (HR20, USP 3/0). The premium Prime range (AMP733HR2030-2) maintains the same needle geometry with improved penetration finish.
Verification and storage: always check the full reference (2×HR20 needle, USP gauge 3/0 and 90 cm length) on the packaging, as well as the integrity of the blister and the expiry date before each use; keep the batch number for traceability in the operating theatre. Product sterile by ethylene oxide and single-use; store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews