Description
1. Commercial Introduction
The polypropylene suture PREMISUT in HR 40 configuration is the usual choice in surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that penetrates tissue with total control. This presentation in USP 0 gauge, with a ½ circle needle with a grooved taper point of 40 mm and a blue thread of 75 cm, is especially indicated for high-demand procedures: cardiovascular surgery, ophthalmology, neurosurgery and general surgery on soft tissues.
It is supplied sterile and ready for individual use in a box of 12 units with batch traceability, which facilitates hospital stock management and presentation to public tenders. Cahnos markets the product keeping the factory reference 732HR4010 without altering characters (SKU AM732HR4010).
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (molecular formula (C3H6)n) that is presented as an uncoated monofilament, dyed blue with phthalocyanine (composition ≥ 99.5% polypropylene, ≤ 0.5% blue dye, in accordance with the US Federal Code). As it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion.
It is not absorbed nor degraded by tissue enzymes: it maintains its tensile strength for a prolonged period in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by connective tissue, helping the wound for more than three months. The HR 40 needle (½ circle, cylindrical body and 40 mm Taperpoint taper point) separates and displaces tissue fibres without cutting them, making it ideal for soft, vascular and poorly distensible planes that require controlled penetration and minimal injury. The grooved finish of the needle body facilitates smooth delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable. Recommended storage below 30 °C, away from humidity and direct sunlight.
3. Technical Specifications
| Parameter | Specification |
| Brand / Line | Premisut (standard line, polypropylene) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue (phthalocyanine) |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 1 thread of 75 cm per unit |
| Thread colour | Identifying blue, high visibility |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Taperpoint conical point (cylindrical body), grooved (HR profile) |
| Needle size | 40 mm (HR 40 profile) |
| Manufacturing quality | Standard (not Prime) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (individual sterile sachets) |
| Factory reference | 732HR4010 |
| Reference Cahnos (SKU) | AM732HR4010 |
Gauge equivalence (USP/EP standard):
| USP size | Metric size | Approximate thread diameter |
| 0 | 3.5 | 0.35 – 0.399 mm |
Variants of the HR 40 family (½ circle, Taperpoint conical point, 40 mm needle):
| Needle profile | USP size | Presentation | Reference |
| HR 40 (standard) | 0 | 1 × 75 cm | 732HR4010 / AM732HR4010 |
| HR 40 (standard) | 1 | 1 × 75 cm | 732HR4001 / AM732HR4001 |
| HR 40 (standard) | 2 | 1 × 75 cm | 732HR4002 / AM732HR4002 |
| HR 40 Prime | 0 | 1 × 75 cm | P732HR4010 / AMP732HR4010 |
| HR 40 Prime | 0 | 2 × 75 cm | P732HR4010.2 / AMP732HR4010.2 |
| HR 40 Prime | 1 | 2 × 75 cm | P732HR4001.2 / AMP732HR4001.2 |
| HR 40 Prime | 2 | 2 × 75 cm | P732HR4002.2 / AMP732HR4002.2 |
4. Equivalences and Cross-References
Reference 732HR4010 corresponds to the official nomenclature of the Premisut range (standard HR 40 profile, 1 thread of 75 cm, USP 0 gauge, blue colour), verified against the manufacturer’s technical data sheet. Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Premisut (Cahnos) | Polypropylene HR 40, USP 0, blue, 1 × 75 cm (standard) | 732HR4010 / AM732HR4010 | Direct product reference | Product analysed in this data sheet |
| Premisut Prime (Cahnos) | Polypropylene HR 40 Prime, USP 0, blue, 1 × 75 cm | P732HR4010 / AMP732HR4010 | Configuration equivalent within the same system | Same measurements, material and HR 40 needle; Prime range steel needle (improved penetration) vs standard |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 0, 75 cm, CT-1 needle ½ circle taper point 36.4 mm | 8424T | Comparable by category (not 1:1) | Code verified in official Ethicon catalogue and authorised distributors; same blue polypropylene base and gauge, but needle of 36.4 mm versus HR 40 of 40 mm; verify IFU before substituting |
| Medtronic / Covidien | Surgipro™ II – polypropylene (with polyethylene) blue monofilament, USP 0, 30″ (75 cm), GS-21 ½ circle taper point needle 37 mm | CP-424 | Comparable by category (not 1:1) | Code verified in GUDID/FDA (Covidien LP, class II, polypropylene monofilament); needle of 37 mm versus 40 mm and copolymer with polyethylene; not interchangeable 1:1 |
| Laboratory Aragó | Blue polypropylene monofilament, C26 ½ circle cylindrical needle of 40 mm, USP 0, 100 cm | 37090 | Comparable by category (not 1:1) | Code verified in official catalogue of Laboratorio Aragó; material, colour, geometry and needle size (40 mm) match; thread length differs (100 cm versus 75 cm) |
| B. Braun | Premilene® / Optilene® – blue polypropylene monofilament | C2090 series (exact code pending confirmation) | Pending confirmation | Same blue polypropylene base; confirm needle geometry and size (½ circle, taper 40 mm), gauge and presentation in official catalogue |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands. Comparisons with PROLENE® 8424T, Surgipro™ CP-424, Laboratorio Aragó 37090 or Premilene®/Optilene® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Tissue to suture: the HR needle with Taperpoint taper point is suitable for soft, vascular and poorly distensible planes that require penetration without cutting (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider triangular point profiles (reverse cutting) from the same Premisut range.
- Needle size: the 40 mm HR is a needle of generous length, indicated for wide suture planes or deep tissue; for smaller areas, shorter needles from the same family are available (HR 35, HR 30, HR 25…).
- Gauge: USP 0 offers medium tension for soft tissues and ligatures of moderate demand; for tissues requiring a larger diameter, USP 1 (AM732HR4001) or USP 2 (AM732HR4002) are available with the same HR 40 needle.
- Prime version: if you are looking for a needle with greater hardness and precision sharpening, the PREMISUT PRIME line offers the same configuration in single thread (AMP732HR4010) and double thread 2 × 75 cm (AMP732HR4010.2).
- Sterility verification: product sterile by ethylene oxide, single use; check the integrity of the blister and the expiry date before each use and keep the reference 732HR4010 and the batch number for traceability in the operating theatre and in case of claim. Store below 30 °C, protected from humidity and direct sunlight.