Description
1. Commercial Introduction
The polypropylene suture PREMISUT 732HR1740 is the reference choice for surgical departments, purchasing centres and tenders that require a non-absorbable thread with predictable behaviour, high tensile strength and minimal tissue reaction. This presentation in USP 4/0 gauge incorporates a ½ circle needle with cylindrical body and 17 mm Taperpoint conical point (HR17 profile) and a 75 cm blue fluted strand: a classic and versatile configuration, highly valued in cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of soft tissues.
Supplied sterile, ready for individual use, in a box of 12 units with individual sachets and batch traceability. Available at Cahnos under the factory reference 732HR1740 (SKU AM732HR1740), kept without altering characters.
2. Technical Explanation
Polypropylene is a linear synthetic polyolefin that is presented as an uncoated monofilament: lacking interstices and wicking effect, it offers very smooth passage through tissue, does not promote bacterial adherence and minimises thread extrusion. Being non-absorbable, it is not degraded by tissue enzymes: it becomes gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR17 needle (½ circle, cylindrical body) with Taperpoint conical point separates and displaces tissue fibres without cutting them, making it especially suitable for soft, friable tissues and thin-walled vascular structures that require controlled penetration and minimal injury. The blue fluted strand ensures optimal visibility and better knot grip on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / line | PREMISUT (polypropylene, standard range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface (knot grip) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 4/0 (metric EP 1.5; diameter 0.15 – 0.199 mm according to USP Pharmacopoeia) |
| Thread length | 75 cm (1 thread per sachet) |
| Thread colour | Ribbed identification blue (high visibility in the surgical field) |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Conical Taperpoint, HR17 profile |
| Needle size | 17 mm (HR17 profile) |
| Configuration | Single needle (1 × HR17) |
| Manufacturing quality | Normal (standard) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation and ligation of soft tissues; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 732HR1740 |
| Reference Cahnos (SKU) | AM732HR1740 |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture):
| USP size | Metric size | Approximate thread diameter |
|---|---|---|
| 4/0 | 1.5 | 0.15 – 0.199 mm |
HR17 family (½ circle, cylindrical body, conical point) within the PREMISUT range:
| USP size | Presentation | Quality | Reference Cahnos |
|---|---|---|---|
| 3/0 | 1 × 75 cm | Standard | AM732HR1730 |
| 4/0 | 1 × 75 cm | Standard | AM732HR1740 (product analysed) |
| 5/0 | 1 × 75 cm | Standard | AM732HR1750 |
| 3/0 | 1 × 75 cm | Prime | AMP732HR1730 |
4. Equivalences and Cross-References
The blue non-absorbable monofilament polypropylene is one of the most standardised permanent suture families on the market (Prolene type). There is no official equivalence table validated by the manufacturer that cross-references 732HR1740 with other brands; the following comparisons are functional, at category level, and not interchangeable 1:1 without prior technical validation against the technical data sheet and IFU of each manufacturer.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| PREMISUT (Cahnos) | Polypropylene Prime – ½ circle conical point HR17, 4/0 blue, 75 cm | P732HR1740 / AMP732HR1740 | Direct equivalence (same system) | Same HR17 needle, gauge, colour and length; only the premium finish of the needle varies. |
| PREMISUT (Cahnos) | Polypropylene HR17, USP 4/0, blue, 75 cm – trocar point (Tapercut) | 732HRT1740 / AM732HRT1740 | Comparable by category (not interchangeable 1:1) | Same gauge, colour, length and 17 mm needle; the point differs: trocar (Tapercut) versus conical (Taperpoint). Different penetration profile for fibrous tissue. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 4-0, 75 cm, RB-1 needle of 17 mm, ½ circle, conical point | 8871H (verified at authorised distributors) | Comparable at category level (not interchangeable 1:1) | Material, gauge, colour, length (75 cm), needle size (17 mm), ½ circle arc and conical point (Taper Point) match. Needle finish and commercial presentation differ (box of 36 units); verify IFU. |
| B. Braun (Aesculap) | Premilene® – blue polypropylene, 4/0 (1.5), 75 cm, HRT 17 needle, ½ circle, trocar point | C2090315 (GUDID GTIN 04046963632243; PREMILENE 4/0 (1.5) 75CM HRT17 (M)) | Comparable at category level (not interchangeable 1:1) | Material, gauge (EP 1.5), 75 cm length and 17 mm needle in ½ circle match; the point (trocar versus conical) and commercial presentation differ. Verify IFU. |
| B. Braun | Optilene® – copolymer of polypropylene with polyethylene, blue, 4/0 (1.5), 75 cm, HR17 needle conical point | C3090013 (verified in B. Braun catalogue) | Comparable at category level (not interchangeable 1:1) | Gauge, colour, length and conical point match; but the material is a copolymer (not pure polypropylene), so it is not interchangeable 1:1. Confirm IFU. |
| Medtronic (Covidien) | Surgipro™ II – copolymer of polypropylene with polyethylene, blue, 4-0, 75 cm, CV-23 needle, ½ circle, conical point | VP-871-X (verified at authorised distributors) | Comparable at category level (not interchangeable 1:1) | Same gauge, colour and length; CV-23 needle with conical point. Copolymer material (polypropylene with polyethylene), composition different from the PREMISUT strand. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; before substituting in tender, protocol or operating theatre, verify one by one the exact gauge, thread length, needle shape and point (conical vs. trocar), needle size, material (pure polypropylene vs. copolymer) and regulatory classification (CE/MDR) of each manufacturer’s actual product. Consult the technical department of Cahnos before using this information in tendering or direct substitution.
5. Selection tips and variants of interest
- Tissue to suture: the HR17 needle with Taperpoint conical point is indicated for soft, friable tissues and thin-walled vascular structures where the aim is to separate fibres without cutting them (cardiovascular surgery, ophthalmology, neurosurgery). For somewhat more fibrous tissues or vascular adventitia, consider the trocar point (Tapercut) variant from the same family (AM732HRT1740).
- Gauge: USP 4/0 (metric 1.5) offers an excellent balance between strength and handling for soft tissues of medium tension and ligatures. If greater strength is required, the same HR17 needle is available in 3/0 (AM732HR1730); for finer tissues, in 5/0 (AM732HR1750).
- Needle size: the 17 mm HR is ideal for surgical fields of medium depth and delicate tissues. For smaller fields, the HR15 is available in the same gauge (AM732HR1540) and for deeper approaches, the HR20, HR25 or HR35 needles within the PREMISUT range (e.g. AM732HR2540 in 4/0).
- Prime range: the PREMISUT Prime line (AMP732HR1740) maintains the same technical configuration with improved needle finish and superior penetration; useful when the protocol requires premium quality.
- Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 732HR1740 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.