Description
1. Commercial Introduction
The polypropylene suture PREMISUT PRIME that Cahnos makes available to surgical services, purchasing centres and tenders is the reference choice when a non-absorbable thread with predictable behaviour, minimal tissue reaction and a needle that passes through tissue with total control is required. This presentation in USP 0 gauge, with a ½ circular needle with grooved conical point (Taperpoint) of 30 mm (HR30 Prime profile) and blue thread of 75 cm, is the classic option for approximating soft tissues, ligatures and high-demand procedures: cardiovascular surgery, ophthalmology and neurosurgery.
It is supplied sterile and ready for individual use in a box of 12 units with batch traceability, facilitating the management of hospital stock and presentation to public tenders. Available under the factory reference P732HR3010 (SKU Cahnos AMP732HR3010), kept without altering characters.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer) that is presented as an uncoated monofilament: as it lacks interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period, in accordance with USP and European Pharmacopoeia gauges, and is gradually encapsulated by fibrous connective tissue, helping the wound for more than three months.
The ½ circular needle with cylindrical body and grooved Taperpoint conical point (HR30 Prime profile) penetrates soft tissues by separating the fibres without cutting them, making it suitable for vascular, cardiovascular tissue and delicate structures that require controlled penetration and minimal injury. The grooved finish of the needle body improves grip in the needle holder and facilitates smooth and consistent delivery during knotting. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Brand / Line | Premisut PRIME (premium range, grooved needle) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| Gauge / USP size | USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges |
| Thread length | 75 cm (1 thread per sachet) |
| Thread colour | Identifying blue, high visibility on the surgical field |
| Needle shape | ½ circle (1/2 circle) |
| Needle type | Taperpoint conical point (cylindrical body), grooved |
| Needle size | 30 mm (HR30 Prime profile) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P732HR3010 |
| Reference Cahnos (SKU) | AMP732HR3010 |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
Calibre equivalence according to USP/EP standard (non-absorbable suture):
| USP size | Metric size | Approximate thread diameter |
|---|---|---|
| 0 | 3.5 | 0.35 – 0.399 mm |
Variants of the HR30 PRIME family (½ circle, Taperpoint conical point, 30 mm needle):
| Needle profile | USP size | Presentation | Reference |
|---|---|---|---|
| HR30 Prime | 0 | 1 × 75 cm | P732HR3010 / AMP732HR3010 (this product) |
| HR30 Prime | 0 | 2 × 75 cm | P732HR3010.2 / AMP732HR3010.2 |
| HR30 Prime | 2/0 | 1 × 75 cm | P732HR3020 / AMP732HR3020 |
| HR30 Prime | 3/0 | 1 × 75 cm | P732HR3030 / AMP732HR3030 |
| HR30 (standard) | 0 | 1 × 75 cm | 732HR3010 / AM732HR3010 |
| 2×HR30 Prime | 2/0 | 2 × 90 cm | P733HR3020-2 / AMP733HR3020-2 |
| 2×HR30 Prime | 3/0 | 2 × 90 cm | P733HR3030-2 / AMP733HR3030-2 |
4. Equivalences and Cross-References
The reference P732HR3010 corresponds to the official nomenclature of the Premisut Prime range (grooved HR30 Prime profile, single 75 cm thread, USP 0 gauge, blue colour), verified against the manufacturer’s technical data sheet. Cahnos markets the product keeping the factory reference without altering characters. There is no official equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tenders or substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (Premisut Prime) | Polypropylene HR30 Prime, USP 0, blue, 2 × 75 cm | P732HR3010.2 / AMP732HR3010.2 | Configuration equivalent within the same system | Same grooved HR30 needle and USP 0 gauge; the presentation changes to double thread |
| Cahnos (Premisut standard) | Polypropylene HR30, USP 0, blue, 1 × 75 cm | 732HR3010 / AM732HR3010 | Direct equivalent within the same family | Same dimensions and material; standard quality needle versus Prime |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, USP 0 | NW846 (blue, 90 cm, ½ circle taper point RB needle, 30 mm) | Comparable by category (not interchangeable 1:1) | Same material, gauge and colour; thread length (90 cm) and single-needle presentation differ |
| Medtronic (Covidien) | Surgipro™ II – polypropylene (with polyethylene) blue monofilament, ½ circle conical point | CP-424 (USP 0, blue, 75 cm, GS-21 needle, 37 mm) | Comparable by category (not interchangeable 1:1) | Same gauge and conical point; copolymer material and 37 mm needle versus 30 mm; verify in official catalogue |
| B. Braun | Premilene® / Optilene® / Dafilon® – blue polypropylene monofilament | C2090 / C3090 series (HR30 USP 0 1×75 cm configuration pending confirmation) | Pending confirmation | Sector family with same clinical indication; confirm needle geometry and length and presentation in official B. Braun catalogue |
| Laboratory Aragó | Blue polypropylene monofilament, ½ circle cylindrical taper point needle | 37020 (USP 0, 37 mm needle, 1 × 75 cm) | Comparable by category (not interchangeable 1:1) | Material, gauge, colour and length (75 cm) match; 37 mm cylindrical taper point needle, not grooved |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands; comparisons with PROLENE®, Surgipro™ II, Premilene®/Optilene® or Laboratorio Aragó are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tenders. Consult the technical department of Cahnos to validate any equivalence before substituting the product.
5. Selection tips and variants of interest
- Tissue to suture: the HR30 needle with grooved Taperpoint conical point is indicated for soft, vascular and slightly distensible flat tissues that require penetration without cutting (cardiovascular surgery, ophthalmology, neurosurgery). For firm tissues or skin, consider trocar (HRT) or triangular point profiles from the same Premisut Prime range.
- Needle size: the 30 mm HR is ideal for medium-depth fields. If you need a shorter needle, you have the HR 25 (ref. AMP732HR2510) or HR 17; for wider planes, the HR 35 (ref. AMP732HR3510) or HR 40 (ref. AMP732HR4010), all in USP 0.
- Gauge: USP 0 (metric 3.5) offers a very balanced tension for vascular ligatures and soft tissues. If the protocol requires a smaller diameter, the same HR30 Prime family offers 3/0 (AMP732HR3030) or 2/0 (AMP732HR3020); for greater resistance, USP 1 (AMP732HR3001H) with the same needle.
- Presentation: if you prefer to make the most of each opening with two armed ends, consider the double thread version 2×75 cm (AMP732HR3010.2) or the 2×90 cm versions from the 733 series (AMP733HR3020-2 and AMP733HR3030-2). As an economical alternative, the standard quality Premisut (AM732HR3010) maintains needle, gauge and colour.
- Prime range: the Premisut Prime line maintains the geometry of the standard version with improved needle finish (superior penetration); useful when the protocol requires premium quality in delicate tissues.
Always verify USP gauge, colour, thread length, needle size and point before placing the order; keep the reference P732HR3010 and the batch number for traceability in the operating theatre. Product sterile by ethylene oxide and single-use: check the integrity of the blister and the expiry date before each use. Store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.