Description
1. Commercial Introduction
The PREMISUT 732HR1550 polypropylene suture is the reference choice for surgical departments, purchasing centres and tenders seeking a non-absorbable thread with predictable behaviour, high tensile strength and minimal tissue reaction. This presentation in USP 5/0 gauge incorporates a ½ circle needle with cylindrical body and 15 mm Taperpoint conical point (HR15 profile) and a 75 cm fluted blue strand: a compact, high-precision configuration highly valued in reduced surgical fields, cardiovascular surgery, ophthalmology, neurosurgery and in the approximation and ligation of delicate soft tissues.
It is supplied sterile, ready for single use, in a box of 12 units with individual sachets and batch traceability, which facilitates hospital stock management and submission to public tenders. Cahnos markets the product keeping the factory reference 732HR1550 (SKU AM732HR1550) unchanged: no digit may be added, removed or reordered when ordering or tendering.
2. Technical Explanation
Polypropylene is a synthetic linear polyolefin (propylene polymer, [C3H6]n) extruded as an uncoated monofilament and dyed blue for maximum visibility in the surgical field. As it has no interstices and no wicking effect, it offers very smooth passage through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises suture extrusion. It is not absorbed or degraded by tissue enzymes: it is gradually encapsulated by fibrous connective tissue and maintains its tensile strength for more than three months, comfortably covering the critical healing phase.
The HR15 needle (½ circle, cylindrical body) with Taperpoint conical point separates and displaces tissue fibres without cutting them, making it suitable for soft, friable tissues and thin-walled vascular structures requiring controlled penetration and minimal injury. The USP 5/0 gauge is very fine and highly manageable, ideal for microsurgery, ophthalmology, microvascular surgery and delicate soft tissue. Sterilised by ethylene oxide (EO); single-use product, not resterilisable.
3. Technical Specifications
3.1. General characteristics
| Brand / line | PREMISUT (polypropylene, standard range) |
| Thread material | Polypropylene monofilament, uncoated, dyed blue |
| Thread structure | Monofilament with grooved surface (knot grip) |
| Absorption | Non-absorbable; gradual encapsulation; wound support for over 3 months |
| USP gauge / size | USP 5/0 (metric EP 1); conforms to USP and European Pharmacopoeia gauges |
| Thread diameter | 0.10 – 0.149 mm (indicative according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 75 cm (1 thread per sachet) |
| Thread colour | Grooved blue identifier, high visibility in the surgical field |
| Needle shape | ½ circle (1/2 circle) |
| Needle body | Cylindrical |
| Tip type | Taperpoint conical, HR15 profile |
| Needle size | 15 mm (HR15 profile) |
| Configuration | Single needle (1 × HR15) |
| Manufacturing quality | Standard (for premium finish see Prime variant) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures; cardiovascular surgery, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Storage | Below 30 °C, protected from moisture and direct sunlight |
| Factory reference | 732HR1550 |
| Reference Cahnos (SKU) | AM732HR1550 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 5/0 | 1 | 0.10 – 0.149 mm |
4. Equivalences and Cross-References
Reference 732HR1550 corresponds to the official nomenclature of the PREMISUT range (HR15 profile, 75 cm single strand, USP 5/0 gauge, blue colour) and Cahnos markets it without altering any characters. Blue non-absorbable polypropylene monofilament is one of the most standardised permanent suture families on the market (commercially of the ‘Prolene’ type). There is no official equivalence table validated by the manufacturer cross-referencing this reference with other brands; comparisons between brands are functional, at category level, and not interchangeable 1:1, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tendering or direct substitution. Consult the Cahnos technical department to validate any equivalence.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos (PREMISUT Prime) | Polypropylene ½ circle HR15 Prime, USP 5/0, blue, 75 cm | P732HR1550 / AMP732HR1550 | Direct range equivalent (same system) | Same HR15 needle, gauge, colour and length; the needle finish changes to Prime (improved penetration). |
| Cahnos (PREMISUT) | Polypropylene ½ circle HR15, USP 4/0, blue, 75 cm | 732HR1540 / AM732HR1540 | Configuration equivalent (same system) | Same HR15 needle and length; USP 4/0 gauge (metric 1.5) with larger diameter for greater strength. |
| Cahnos (PREMISUT) | Polypropylene ½ circle HR15, USP 6/0, blue, 75 cm | 732HR1560 / AM732HR1560 | Configuration equivalent (same system) | Same HR15 needle and length; finer USP 6/0 gauge for microsurgery and ophthalmology. |
| Ethicon (J&J MedTech) | PROLENE® – blue polypropylene monofilament, 5/0, 90 cm, double RB-1 Taperpoint needle of 17 mm | 8556G (2xRB-1) | Comparable by category (not interchangeable 1:1) – confirmed code | Same material, gauge and colour; the needle differs (17 mm vs. the 15 mm HR15) and the length (90 cm and double needle vs. 75 cm single needle). Verified in the Ethicon catalogue and authorised distribution. |
| B. Braun (Aesculap) | Premilene® – blue polypropylene monofilament, 5/0 (EP 1), 90 cm, double needle 2xHR26 | CVC2090905 | Comparable by category (not interchangeable 1:1) – confirmed code | Same material, gauge and colour; HR26 needle of 26 mm and double-needle format vs. HR15 of 15 mm and single needle. Verified in the B. Braun catalogue and AccessGUDID. |
| B. Braun (Aesculap) | Optilene® – polypropylene/polyethylene copolymer, blue, 5/0 (EP 1), 90 cm, double needle 2xHR26 | CVC3090905 | Comparable by category (not interchangeable 1:1) – confirmed code | The material differs (polypropylene and polyethylene copolymer vs. pure polypropylene) and the needle format. Verified in the B. Braun catalogue. |
Mandatory technical note: there is no equivalence table validated by the manufacturer cross-referencing reference 732HR1550 with other brands; comparisons with PROLENE®, Premilene® or Optilene® are functional, at category level, and must be confirmed against each manufacturer’s technical data sheet or IFU before use in tendering or direct substitution.
5. Selection tips and variants of interest
- Tissue to suture: the HR15 needle with Taperpoint conical point is indicated for soft, friable tissues and thin-walled vascular structures where the aim is to separate fibres without cutting them (cardiovascular surgery, ophthalmology, neurosurgery). For somewhat more fibrous tissues or vascular adventitia, consider the trocar-point (Tapercut) variant of the same family (ref. AM732HRT1540).
- Gauge: USP 5/0 (metric 1) is very fine and highly manageable. With the same HR15 needle, the 4/0 (AM732HR1540) is available for greater strength and the 6/0 (AM732HR1560) for planes of maximum fineness.
- Needle size: the 15 mm HR is compact and ideal for reduced surgical fields and precision surgery. If greater reach is required, the HR17 (AM732HR1750 in 5/0) or HR20/HR25 from the same PREMISUT range are available.
- Prime range: the PREMISUT Prime line (AMP732HR1550) maintains the same needle geometry and gauge with a premium improved-penetration finish; useful when the protocol requires superior quality. As an economical alternative, the standard version AM732HR1550 maintains needle, gauge and colour.
- Prior verification: always check USP gauge, colour, suture length and needle size before placing the order, as well as the integrity of the blister and the expiry date before each use. Keep reference 732HR1550 and the batch number for traceability in the operating theatre. For special B2B conditions by volume or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews