Description
1. Product Presentation
The polyester suture PREMISUT is the reference choice for general surgery, ophthalmology, neurosurgery and purchasing centres looking for a non-absorbable, high-strength thread with predictable clinical performance. This reference combines a braided multifilament coated with silicone, USP 2/0 calibre and a green 75 cm thread, mounted on a straight 60 mm needle (GS 60) with a conventional cutting triangular point.
Its non-grooved surface ensures smooth passage through tissue, excellent knot retention and prolonged mechanical support during healing. Sterile product, ready to use, presented in a box of 12 units.
2. Technical explanation
Polyester (polyethylene terephthalate) is a non-absorbable synthetic polymer with a braided multifilament structure, providing flexibility, high tensile strength and knot security. The silicone coating reduces friction, facilitates thread sliding through tissues and minimises the saw effect, improving handling without compromising knot retention.
As it is not absorbed, the suture undergoes gradual encapsulation by the tissue and maintains its structural integrity for more than three months, the period in which the wound completes its critical healing phase. The straight 60 mm needle with triangular point and conventional cutting (GS 60) is designed to precisely penetrate firm, low-elasticity tissues, facilitating manual suturing on directly accessible surfaces and providing absolute control of the path, especially in ligatures, approximation of superficial planes and ophthalmic surgery. The green colour ensures optimal visibility of the thread on the surgical field.
3. Technical Specifications
| Parameter | Specification |
| Material | Silicone-coated braided multifilament polyester (polyester – polyethylene) |
| Structure | Braided multifilament, non-grooved surface |
| Absorption | Non-absorbable, with gradual encapsulation |
| Gauge | USP 2/0 (metric 3) |
| Thread length | 75 cm |
| Needle | Straight, triangular point, conventional cutting |
| Needle size | GS 60 (60 mm) |
| Colour | Green (identification standard; optional white) |
| Sterilisation | Ethylene oxide (EO) |
| Quality | Standard (PREMISUT) |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference | AM852GS6020 (factory 852GS6020) |
4. Equivalences and Cross-References
Non-absorbable braided polyester is the most widespread permanent suture family on the market for soft tissue approximation and ligatures. In terms of material and clinical behaviour, this Premisut suture is comparable by category (not interchangeable 1:1) with the main commercial ranges of braided polyester:
| Manufacturer / Brand | Family / Model | Reference code (example) | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J) | ETHIBOND EXCEL | W6759 / W6760 (USP 2/0, braided green) | Comparable by category, not interchangeable 1:1 | Polybutylate coating (not silicone); cardiovascular curved needles in standard refs., not straight GS 60 needle |
| B. Braun | PremiCron | C0026306 (USP 2/0, green, 90 cm) | Comparable by category, not interchangeable 1:1 | Similar braided structure and silicone coating; curved 1/2 circle needle in standard ref. |
| Medtronic (Covidien) | Surgidac / Ti-Cron | 8886309061 (USP 0, braided green, GS-21 needle) | Comparable by category, not interchangeable 1:1 | PTFE coating; curved 1/2 circle needle; gauges and needle geometry different from straight GS 60 |
| Teleflex | Tevdek | Ref. per catalogue (braided PTFE-coated) | Comparable by category, not interchangeable 1:1 | PTFE coating and presentations with different needle; verify technical data sheet before substitution |
Important note: there is no equivalence table validated by the manufacturer that cross-references these brands in the straight GS 60 conventional cutting needle format. The straight GS 60 needle is only interchangeable within the Premisut system itself. Within the Cahnos catalogue, this reference maintains configuration equivalence with the Prime quality version (ref. AMP852GS6020, factory code P852GS6020), which retains identical needle, thread and measurements with superior quality control. Before using it in tenders or direct substitution, consult the technical department of Cahnos.
5. Selection tips and variants of interest
Select the gauge according to the tissue and the tension the suture must withstand: USP 2/0 is suitable for tissues with medium mechanical demand and for ligatures; consider 3/0 or finer gauges for subcutaneous tissue and precision ophthalmic surgery. The conventional cutting straight needle is ideal for ligature sutures and approximation with direct access to the surgical field; for ophthalmic and microsurgery, consult the version with a 3/8 circular reverse cutting needle DS 30 mm (ref. AM852DS3020, polyester, USP 2/0, green). If your purchasing centre requires a higher specification profile, the Prime quality (ref. AMP852GS6020) maintains the same needle and thread configuration with superior quality control. The standard presentation is a box of 12 units with a minimum order of 30 boxes; for larger volumes, supply agreements or special gauges, contact the commercial department of Cahnos.





Reviews
There are no reviews yet.