Non-absorbable braided polyester suture Premisut Prime, conventional cutting straight needle GS 60 mm, USP 2/0, green, 75 cm thread (box of 12 units) | Ref. AMP852GS6020

Original price was: 22,14 €.Current price is: 17,40 €.

Non-absorbable braided multifilament polyester suture Premisut Prime, mounted on a 60 mm straight needle with triangular point and conventional cutting (GS 60), USP 2/0 gauge and 75 cm green thread, with non-grooved surface and silicone coating. Its gradual encapsulation and high tensile strength maintain wound support for more than three months, making it suitable for soft tissue approximation, ligatures, ophthalmology and neurosurgery. Sterilised by ethylene oxide. Presentation in a box of 12 units and minimum order of 30 boxes, availability on request for purchasing centres and operating theatre services. Ref. AMP852GS6020.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP852GS6020

Description

1. Product Presentation

The Premisut Prime polyester suture is the reference choice for general surgery, ophthalmology, neurosurgery and purchasing centres seeking a high-strength non-absorbable suture with predictable clinical performance. This reference combines a silicone-coated braided multifilament, USP 2/0 gauge and a 75 cm green thread, mounted on a 60 mm straight needle (GS 60) with a conventional cutting triangular point. Its Prime quality ensures a regular surface, smooth passage through tissue and excellent knot retention, providing prolonged mechanical support during healing. Sterile product, ready to use, presented in a box of 12 units.

2. Technical explanation

Polyester (polyethylene terephthalate) is a non-absorbable synthetic polymer presented in a braided multifilament structure, providing flexibility, high tensile strength and knot security. The silicone coating reduces friction, facilitates the passage of the thread through tissues and minimises the sawing effect, improving handling without compromising knot retention. As it is not absorbed, the suture undergoes gradual encapsulation by the tissue and maintains its structural integrity for more than three months, the period in which the wound completes its critical healing phase.

The 60 mm straight needle with triangular point and conventional cutting (GS 60) is designed to precisely penetrate firm, inelastic tissues, facilitating manual suturing on directly accessible surfaces and providing absolute control of the path, especially in ligatures, approximation of superficial planes and ophthalmic surgery. The green colour ensures optimal visibility of the thread on the surgical field and its non-grooved surface promotes smooth passage through tissue.

3. Technical Specifications

Parameter Specification
Material Silicone-coated braided multifilament polyester (polyester – polyethylene)
Structure Braided multifilament, non-grooved surface
Absorption Non-absorbable, with gradual encapsulation
Gauge USP 2/0 (metric 3)
Thread length 75 cm
Needle Straight, triangular point, conventional cutting
Needle size GS 60 (60 mm)
Colour Green (identification standard)
Sterilisation Ethylene oxide (EO)
Quality Prime (PREMISUT)
Indications Approximation of soft tissues, ligatures, ophthalmology and neurosurgery
Presentation Box of 12 units
Minimum order 30 boxes
Reference AMP852GS6020

4. Equivalences and Cross-References

Non-absorbable braided polyester is the most widespread permanent suture family on the market for soft tissue approximation and ligatures. In terms of material and clinical behaviour, this Premisut Prime suture is comparable by category to the main commercial ranges of braided polyester: Ethibond Excel and Mersilene (Ethicon / Johnson & Johnson), PremiCron (B. Braun), Surgidac and Ti-Cron (Medtronic / Covidien) and Tevdek (Teleflex, PTFE-coated).

Manufacturer / Brand Family / Model Reference code (example) Equivalence level Technical differences / Remarks
Ethicon (J&J) ETHIBOND EXCEL W6759 / W6760 (USP 2/0, braided green) Comparable by category, not interchangeable 1:1 Polybutylate coating (not silicone); cardiovascular curved needles in standard refs, not GS60 straight needle
B. Braun PremiCron C0026306 (USP 2/0, green, 90 cm) Comparable by category, not interchangeable 1:1 Same silicone coating and braided structure; curved needle 1/2 circle in standard ref.
Medtronic (Covidien) Surgidac / Ti-Cron 8886309061 (USP 0, braided green, GS-21 needle) Comparable by category, not interchangeable 1:1 PTFE coating; curved needle 1/2 circle in standard ref.; gauges and needles different from straight GS60

Important note: there is no manufacturer-validated equivalence table cross-referencing these brands in the conventional cutting GS 60 straight needle format; the cited references are examples verified in official catalogues or from authorised distributors for the material, but with different needle geometry. Before using them in tenders or direct substitution, consult the technical department of Cahnos and verify the manufacturer’s technical data sheet, since the GS 60 straight needle is only interchangeable within the Premisut system itself.

Within the Cahnos catalogue, this reference maintains reference equivalence with the factory code P852GS6020 (Premisut Prime, GS60, 2/0, green, 75 cm, box of 12 units).

5. Selection tips and variants of interest

Select the gauge according to the tissue and the tension the suture must withstand: USP 2/0 is suitable for tissues with medium mechanical demand and for ligatures; consider 3/0 or finer gauges for subcutaneous tissue and precision ophthalmic surgery. The conventional cutting straight needle is ideal for ligature sutures and approximation with direct access to the surgical field; for ophthalmic surgery and microsurgery, consult the versions with a 3/8 circular reverse cutting needle (ref. AMP852DS3020, Prime polyester, USP 2/0, green, DS 30 mm). If your budget is tighter, the standard quality AM852GS6020 maintains the same needle and thread configuration with conventional quality control. The standard presentation is the box of 12 units with a minimum order of 30 boxes; for larger volumes, supply agreements or special gauges, contact the commercial department of Cahnos.

Additional information

Material

Silicone-coated braided multifilament polyester (polyester – polyethylene)

Structure

Braided multifilament, non-grooved surface

Absorption

Non-absorbable, gradual encapsulation

Gauge

USP 2/0 (metric 3)

Needle type

Straight

Needle tip

Triangular, conventional cutting

Needle size

GS 60 (60 mm)

Sterilisation

Ethylene oxide (EO)

Quality

Prime (PREMISUT)

Indications

Approximation of soft tissues, ligatures, ophthalmology and neurosurgery

Presentation

Box of 12 units

Minimum order

30 boxes

Manufacturer reference

P852GS6020

Medida de aguja

GS 60

Usp

2/0

Color

Green

Medida de hilo

75 cm

Tipo de aguja

Conventional triangular

Forma de aguja

Straight Cut

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Non-absorbable braided polyester suture Premisut Prime, conventional cutting straight needle GS 60 mm, USP 2/0, green, 75 cm thread (box of 12 units) | Ref. AMP852GS6020”

Your email address will not be published. Required fields are marked *