Description
1. Product Presentation
The Premisut Prime polyester suture is the reference choice for general surgery, ophthalmology, neurosurgery and purchasing centres seeking a high-strength non-absorbable suture with predictable clinical performance. This reference combines a silicone-coated braided multifilament, USP 2/0 gauge and a 75 cm green thread, mounted on a 60 mm straight needle (GS 60) with a conventional cutting triangular point. Its Prime quality ensures a regular surface, smooth passage through tissue and excellent knot retention, providing prolonged mechanical support during healing. Sterile product, ready to use, presented in a box of 12 units.
2. Technical explanation
Polyester (polyethylene terephthalate) is a non-absorbable synthetic polymer presented in a braided multifilament structure, providing flexibility, high tensile strength and knot security. The silicone coating reduces friction, facilitates the passage of the thread through tissues and minimises the sawing effect, improving handling without compromising knot retention. As it is not absorbed, the suture undergoes gradual encapsulation by the tissue and maintains its structural integrity for more than three months, the period in which the wound completes its critical healing phase.
The 60 mm straight needle with triangular point and conventional cutting (GS 60) is designed to precisely penetrate firm, inelastic tissues, facilitating manual suturing on directly accessible surfaces and providing absolute control of the path, especially in ligatures, approximation of superficial planes and ophthalmic surgery. The green colour ensures optimal visibility of the thread on the surgical field and its non-grooved surface promotes smooth passage through tissue.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Material | Silicone-coated braided multifilament polyester (polyester – polyethylene) |
| Structure | Braided multifilament, non-grooved surface |
| Absorption | Non-absorbable, with gradual encapsulation |
| Gauge | USP 2/0 (metric 3) |
| Thread length | 75 cm |
| Needle | Straight, triangular point, conventional cutting |
| Needle size | GS 60 (60 mm) |
| Colour | Green (identification standard) |
| Sterilisation | Ethylene oxide (EO) |
| Quality | Prime (PREMISUT) |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference | AMP852GS6020 |
4. Equivalences and Cross-References
Non-absorbable braided polyester is the most widespread permanent suture family on the market for soft tissue approximation and ligatures. In terms of material and clinical behaviour, this Premisut Prime suture is comparable by category to the main commercial ranges of braided polyester: Ethibond Excel and Mersilene (Ethicon / Johnson & Johnson), PremiCron (B. Braun), Surgidac and Ti-Cron (Medtronic / Covidien) and Tevdek (Teleflex, PTFE-coated).
| Manufacturer / Brand | Family / Model | Reference code (example) | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J) | ETHIBOND EXCEL | W6759 / W6760 (USP 2/0, braided green) | Comparable by category, not interchangeable 1:1 | Polybutylate coating (not silicone); cardiovascular curved needles in standard refs, not GS60 straight needle |
| B. Braun | PremiCron | C0026306 (USP 2/0, green, 90 cm) | Comparable by category, not interchangeable 1:1 | Same silicone coating and braided structure; curved needle 1/2 circle in standard ref. |
| Medtronic (Covidien) | Surgidac / Ti-Cron | 8886309061 (USP 0, braided green, GS-21 needle) | Comparable by category, not interchangeable 1:1 | PTFE coating; curved needle 1/2 circle in standard ref.; gauges and needles different from straight GS60 |
Important note: there is no manufacturer-validated equivalence table cross-referencing these brands in the conventional cutting GS 60 straight needle format; the cited references are examples verified in official catalogues or from authorised distributors for the material, but with different needle geometry. Before using them in tenders or direct substitution, consult the technical department of Cahnos and verify the manufacturer’s technical data sheet, since the GS 60 straight needle is only interchangeable within the Premisut system itself.
Within the Cahnos catalogue, this reference maintains reference equivalence with the factory code P852GS6020 (Premisut Prime, GS60, 2/0, green, 75 cm, box of 12 units).
5. Selection tips and variants of interest
Select the gauge according to the tissue and the tension the suture must withstand: USP 2/0 is suitable for tissues with medium mechanical demand and for ligatures; consider 3/0 or finer gauges for subcutaneous tissue and precision ophthalmic surgery. The conventional cutting straight needle is ideal for ligature sutures and approximation with direct access to the surgical field; for ophthalmic surgery and microsurgery, consult the versions with a 3/8 circular reverse cutting needle (ref. AMP852DS3020, Prime polyester, USP 2/0, green, DS 30 mm). If your budget is tighter, the standard quality AM852GS6020 maintains the same needle and thread configuration with conventional quality control. The standard presentation is the box of 12 units with a minimum order of 30 boxes; for larger volumes, supply agreements or special gauges, contact the commercial department of Cahnos.