Description
1. Product Presentation
The non-absorbable polyester suture Premisut Prime is the reference choice for general surgery, ophthalmology, neurosurgery and purchasing centres seeking a permanent, high-strength thread with predictable clinical performance. This reference combines a braided multifilament coated with silicone, USP 2/0 gauge and a green 75 cm thread, mounted on a ⅜ circular 30 mm needle (DS 30) with a reverse cutting triangular point. Its Prime quality guarantees a regular surface, smooth passage through tissue and excellent knot retention, providing prolonged mechanical support during healing. Sterile product, ready to use, presented in a box of 12 units.
2. Technical explanation
Polyester (polyethylene terephthalate) is a non-absorbable synthetic polymer that comes in a braided multifilament structure, providing flexibility, high tensile strength and knot security. The silicone coating reduces friction, favours the sliding of the thread through tissues and minimises the saw effect, improving handling without compromising knot retention. As it is not absorbed, the suture undergoes gradual encapsulation by the tissue and maintains its structural integrity for more than three months, the period in which the wound completes its critical healing phase.
The ⅜ circular needle with reverse cutting triangular point (reverse cutting, DS 30 mm) is designed to precisely penetrate firm, inelastic tissues, cutting the tissue plane without tearing it, making it especially useful in ophthalmic surgery, microsurgery and approximation of planes with access to reduced working fields. The green colour ensures optimal visibility of the thread on the surgical field and its non-grooved surface favours smooth sliding through tissue.
3. Technical Specifications
| Parameter | Specification |
| Material | Braided multifilament polyester coated with silicone (polyethylene terephthalate / polyester – polyethylene) |
| Structure | Braided multifilament, non-grooved surface |
| Absorption | Non-absorbable, with gradual encapsulation |
| Gauge | USP 2/0 (metric 3) |
| Thread length | 75 cm |
| Needle | ⅜ circular, triangular point, reverse cutting |
| Needle size | DS 30 (30 mm) |
| Colour | Green (identification standard; optional white) |
| Sterilisation | Ethylene oxide (EO) |
| Quality | Prime (PREMISUT) |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference | AMP852DS3020 (factory equivalent P852DS3020) |
4. Equivalences and Cross-References
Non-absorbable braided polyester is the most widespread permanent suture family on the market for soft tissue approximation and ligatures. In terms of material and clinical behaviour, this Premisut Prime suture is comparable by category (not interchangeable 1:1) with the main commercial ranges of braided polyester:
| Manufacturer / Brand | Family / Model | Reference code | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J) | ETHIBOND EXCEL | W932 (USP 2/0, green, 75 cm, MH-1 needle); also X563H | Comparable by category, not interchangeable 1:1 | Polybutylate coating (not silicone); curved MH-1 needle, not DS 30 reverse cutting |
| B. Braun | PremiCron | C0026306 (USP 2/0, green, 90 cm, 2xHRC17); C0026739 (USP 2/0, green, 75 cm, 2xHR26) | Comparable by category, not interchangeable 1:1 | Same silicone coating and braided structure; curved cardiovascular needles (HR/HRC), not DS 30 reverse cutting |
| Medtronic (Covidien) | Surgidac / Ti-Cron | 8886309061 (USP 0, green, 75 cm, GS-21 needle) | Comparable by category, not interchangeable 1:1 | USP 0 gauge (not 2/0); GS-21 1/2 circle trocar point needle; Surgidac uncoated and Ti-Cron with silicone |
| Teleflex | Tevdek / Tevdek II | 7-744 / 7-717 (USP 2/0, green, 75 cm, KT-2 / T-2 needles) | Comparable by category, not interchangeable 1:1 | PTFE coating (not silicone); different needles and presentation formats |
Important note: there is no manufacturer-validated equivalence table cross-referencing these brands with the DS 30 ⅜ circular reverse cutting needle configuration; the cited references have been verified in official catalogues or from authorised distributors for the material and gauge, but with a different needle geometry. The DS 30 needle is only interchangeable within the Premisut system itself. Before using them in tenders or direct substitution, consult the technical department of Cahnos and verify the manufacturer’s technical data sheet.
Within the Cahnos catalogue, this reference maintains configuration equivalence with the standard quality version AM852DS3020 (same DS 30 needle, USP 2/0, green, 75 cm, with conventional quality control).
5. Selection tips and variants of interest
Select the gauge according to the tissue and the tension the suture must withstand: USP 2/0 is suitable for tissues with medium mechanical demand and for ligatures; consider 3/0 or finer gauges for subcutaneous tissue and precision ophthalmic surgery, and higher gauges USP 0 or USP 1 for planes subjected to greater tension (Prime variants AMP852DS3010 and AMP852DS3001, same needle and thread). If your purchasing centre requires a higher specification profile, Prime quality (this reference) maintains the same configuration as the standard version AM852DS3020 with superior quality control. For ligature sutures with direct access and a straight 60 mm needle (GS 60), see references AMP852GS6020 (Prime) and AM852GS6020 (standard). The standard presentation is a box of 12 units with a minimum order of 30 boxes; for larger volumes, supply agreements or special gauges, contact the commercial department of Cahnos.