Description
1. Product Presentation
The non-absorbable polyester suture Premisut Prime is the reference choice for professionals seeking a high-performance suture for precision procedures. Its double-needle configuration with a ½ circle spatula needle type Micropoint (2xHSP) of 8 mm, USP 5/0 gauge, white thread of 45 cm and silicone coating makes it especially valuable in ophthalmology, neurosurgery and soft tissue surgery, where every needle pass must be controlled and atraumatic. Each box contains 12 sterile units, individually packaged and ready for the operating theatre, with a minimum order of 10 boxes.
2. Technical Explanation
This suture is composed of a core of braided multifilament polyester (polyester-polyethylene) coated with silicone, which gives it a uniform, non-grooved surface, with low tissue friction and excellent knot behaviour. Being non-absorbable, it does not degrade by enzymatic action: it offers sustained tensile strength and gradual encapsulation by connective tissue that maintains wound support for more than three months, ideal for approximation and ligation of soft tissues with slow healing.
The spatula needle with a flattened section separates tissue fibres rather than cutting them, minimising trauma and tearing on delicate lamellar tissues (cornea, sclera, dura mater). The 2xHSP configuration incorporates a needle at each end of the thread (double needle), allowing continuous sutures without re-threading and a more balanced distribution of tension, with a ½ circle arc that facilitates the angle of attack in deep or limited-access areas. The product is supplied sterile, single-use and non-reesterilizable.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Material | Braided multifilament polyester (polyester-polyethylene) coated with silicone |
| Structure | Braided multifilament, non-grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, high tensile strength (support for more than 3 months) |
| Needle shape | ½ circle (1/2) |
| Needle type | Spatulated Micropoint (Spatula) |
| Needle size | 8 mm · Double needle 2xHSP 8 Prime (2 needles) |
| Number of needles | 2 (double needle) |
| USP size | 5/0 (diameter 0.1 mm; metric EP 1) |
| Thread colour | White |
| Thread length | 45 cm |
| Quality | Prime |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use; do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Presentation | Box of 12 units (individual sterile sachets) |
| Minimum order | 10 boxes |
| Factory reference | P871HSP850-2 (range coding pattern; confirm on the sachet label) |
| SKU Cahnos | AMP871HSP850-2 |
4. Equivalences and Cross-References
The non-absorbable braided polyester suture is a well-established category in the market, present in most major manufacturers. The references indicated below are comparable at category level (same product type, same general clinical indication and same USP 5/0 gauge), but should not be considered 1:1 interchangeable: they differ in the type of coating, needle geometry (radius and point), exact diameter and presentation. The codes cited come from distributor references and are pending confirmation against the manufacturer’s official technical data sheet; always verify them before substituting.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | ETHIBOND EXCEL (braided polyester coated with polybutilate) | X884G / 746G (distributor references; pending confirmation) | Comparable by category | Polybutilate coating versus silicone; configurations with ½ or ¼ radius and spatula point; confirm exact code and point in official technical data sheet |
| Ethicon (J&J MedTech) | MERSILENE (braided polyester without coating) | 746G / 1760G (distributor references; pending confirmation) | Comparable by category | Uncoated; more resistant tissue passage; needle and presentation to be verified |
| B. Braun | PREMICRON / DAGROFIL | Pending confirmation | Comparable by category | Coating and needle geometry to be confirmed in official data sheet |
| Medtronic (Covidien) | TI-CRON (polyester coated with silicone) | Pending confirmation | Comparable by category | Similar silicone coating; confirm spatula point and ½ radius in official catalogue |
| Assut Sutures | ASTRALEN (braided polyester) | 332085W (distributor reference; pending confirmation) | Comparable by category | Same dimensions and material; confirm double-needle configuration, point and coating according to Assut’s official technical data sheet |
| Atramat | POLISIL / POLYESTER (braided polyester) | E-EA855/2-45B (distributor reference; pending confirmation) | Functional comparison | Usual configuration in ¼ circle; verify ½ radius, point and commercial presentation |
| SMI | SURGICRYL POLYESTER | Pending confirmation | Not verified | No technical cross-reference validated with an official source |
Important note: there is no equivalence table validated by the manufacturer for this exact reference (USP 5/0, white, 2xHSP of 8 mm). The SKU AMP871HSP850-2 is Cahnos’s own code and the factory reference follows the P871HSP850-2 pattern of the range. Consult Cahnos’s technical department before using this information in tenders or direct substitutions of another brand.
5. Selection tips and variants of interest
Needle geometry is the decisive criterion in microsurgery: the ½ circle spatula needle (2xHSP) offers a deep arc with a large angle of attack, ideal for deep areas, lamellar tissues and planes with limited access. For the same format in other curvatures or colours, consult the references of the same Premisut Prime family:
- AMP851HSP850-2: ½ circle spatula, green, 5/0, 45 cm (same configuration in green).
- AMP871VSP850-2: ¼ circle spatula, white, 5/0, 45 cm (flatter arc, common in anterior ophthalmology).
- AMP851VSP850-2: ¼ circle spatula, green, 5/0, 45 cm.
- AMP871VSP840-2: ¼ circle spatula, white, 4/0, 45 cm (finer gauge).
- AMP851DSP850-2: ⅜ circle spatula, green, 5/0, 45 cm (intermediate arc).
Always verify the needle-tissue combination: the spatula point is optimal for fine lamellar tissues (cornea, sclera, dura mater); for denser tissues consider conical-point or cutting needles from the same Premisut Prime range. Before ordering, confirm the specialty, needle radius and USP gauge required in your surgical protocol. Single-use, sterile and non-reesterilizable product; store in a cool, dry place, protected from light.





Reviews