Description
1. Introduction
The polyester suture Premisut PRIME is the choice of professionals seeking a high-performance non-absorbable material, with exceptional handling and predictable tissue behaviour. Its configuration with a long 55 mm needle in the Heavy version makes it a reliable ally in soft tissue procedures, vascular ligations, ophthalmology and neurosurgery, where sustained tensile strength and controlled penetration in deep planes are required.
Presented in a box of 12 units, it is designed for centralised purchasing by operating theatre services and hospital purchasing centres. Reference Cahnos: AMP852HRT5505H.4.
2. Technical explanation
The thread is composed of fine fibres of polyethylene terephthalate (polyester) braided into a compact multifilament structure and coated with silicone, which improves passage through tissue, facilitates knot seating and reduces tissue trauma. Being non-absorbable, it does not degrade by enzymatic action: it maintains its tensile strength permanently and provides wound support for more than three months while gradual encapsulation by fibrous connective tissue takes place.
The ½ circle needle allows suturing in confined spaces with controlled rotational movements, while the trocar point (tapercut) combines the penetration of a cutting needle with the minimal aggression of a round needle: it passes through dense or fibrous tissue without tearing, reducing bleeding and tissue injury. The Heavy version reinforces the needle body to withstand the additional traction required by a thick gauge such as USP 5, maintaining flexural resistance during suturing.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Thread material | Polyester (polyethylene terephthalate) braided multifilament, silicone-coated |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | 5 USP |
| Length / thread size | 4 x 75 cm |
| Needle shape | ½ circle |
| Needle body / tip | Cylindrical body, trocar point (tapercut) |
| Needle size | HRT 55 mm Heavy (non-grooved) |
| Needle material | Stainless steel |
| Thread colour | Green (also available in white depending on series) |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Sterilisation | Ethylene oxide (EO) |
| Presentation | Box of 12 units |
| Regulatory standard | Exceeds USP and EP requirements; compliant with Regulation (EU) 2017/745 (MDR) |
| Reference Cahnos | AMP852HRT5505H.4 (factory code P852HRT5505H.4) |
Specifications according to the technical data sheet and official price list of the Premisut polyester family. Size indicated according to the manufacturer’s USP nomenclature.
4. Equivalences and Cross-References
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut PRIME (PREMISTER PRIME family) | Polyester ½ circle trocar point HRT55 Heavy, size 5, green, 4 x 75 cm | P852HRT5505H.4 (factory code) | Exact reference equivalence | Same product; material, HRT 55 Heavy needle, size 5, colour and thread length match. It is the official factory code for this same reference. |
| Premisut PRIME (PREMISTER PRIME family) | Polyester ½ circle trocar point HRT55 Heavy, size 5, green, 90 cm | AMP853HRT5505H (P853HRT5505H) | Family equivalence | Same HRT 55 Heavy needle, same size 5 and colour; thread in 90 cm presentation instead of 4 x 75 cm. Not interchangeable 1:1 if thread length is a requirement. |
| B. Braun | PremiCron (braided polyester coated with silicone), green, 5 (7), 4 x 75 cm, HRT55 | G0026723 (according to official B. Braun catalogue; confirm before use) | Comparable by category, not interchangeable 1:1 | Non-absorbable silicone-coated polyester multifilament, same size 5, presentation 4 x 75 cm and HRT55 needle. Verify the EP designation of the size and supply policy before substituting. |
| Ethicon (Johnson & Johnson MedTech) | ETHIBOND EXCEL (braided polyester coated with polybutylate), tapercut, size 5, green, 4 x 75 cm | MB46G (V-40 needle of 48 mm, according to authorised distributor references) | Comparable by category, not interchangeable 1:1 | Same type of thread (non-absorbable braided polyester) and size 5, but 48 mm needle instead of 55 mm and polybutylate coating instead of silicone. Verify ½ angle, tapercut point and surgical field compatibility. |
Note: there is no equivalence table validated by the manufacturer cross-referencing this Premisut PRIME reference with other brands; the cross-references with B. Braun and Ethicon are functional category comparisons pending official confirmation. Consult the technical department before use in tenders or reference substitution.
5. Selection tips and variants of interest
- Deep planes and dense tissues: the 55 mm Heavy trocar (tapercut) needle is indicated when controlled penetration with a long throw is required; if the surgical field is more superficial, consider the HRT40 (AMP852HRT4030H, size 3/0) or HRT48 (AMP852HRT4810, size 0) variants.
- Thread length protocols: if your centre prefers 90 cm thread with the same HRT55 needle and size 5, refer to reference AMP853HRT5505H; this data sheet (AMP852HRT5505H.4) is the 4 x 75 cm multipack presentation.
- Medium sizes: for soft tissue approximation with a smaller size, the Premisut PRIME family offers size 2 in 4 x 75 cm presentation with HRT45 needle (AMP852HRT4502.4) or size 3/0 Heavy HRT40 (AMP852HRT4030H).
- Verify before substituting brands: always check angle (½), needle size (55 mm), point type (trocar/tapercut), Heavy version, USP size and coating in the alternative manufacturer’s technical data sheet.
- Ordering and storage: sterile product by ethylene oxide, presented in a box of 12 units. Request a personalised quote from our technical-commercial department for hospital volumes.





Reviews